cve/2024/CVE-2024-7707.md

18 lines
1.0 KiB
Markdown
Raw Permalink Normal View History

2024-08-13 18:35:37 +00:00
### [CVE-2024-7707](https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2024-7707)
![](https://img.shields.io/static/v1?label=Product&message=FH1206&color=blue)
![](https://img.shields.io/static/v1?label=Version&message=%3D%2002.03.01.35%20&color=brighgreen)
![](https://img.shields.io/static/v1?label=Vulnerability&message=CWE-121%20Stack-based%20Buffer%20Overflow&color=brighgreen)
### Description
A vulnerability was found in Tenda FH1206 02.03.01.35 and classified as critical. Affected by this issue is the function formSafeEmailFilter of the file /goform/SafeEmailFilter of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
### POC
#### Reference
- https://github.com/VodkaVortex/IoT/blob/main/formSafeEmailFilter.md
#### Github
- https://github.com/fkie-cad/nvd-json-data-feeds