Files
cve/cves/2016/CVE-2016-7165.md
0xMarcio 08d697bd12 Carry each record's title, vendor and product, and search them first
A CVE List V5 record names what it is about: a title such as "PAN-OS:
Arbitrary File Creation Leads to OS Command Injection Vulnerability in
GlobalProtect", a vendor and its products. None of it was kept, so a query
for pan-os or prisma access only found records whose prose happened to say
so. Every record now opens with the title in bold and a Vendor badge per
affected vendor, refreshed from a local CVE List checkout in one pass and
kept current by the daily sync for the records it fetches. Only the lines
above the description move; descriptions and PoC sections are untouched.
The pass also settled the heading link on cve.org and trimmed the stray
space some version badges carried.

The site index carries title, vendor and product for the 40 percent of
indexed CVEs whose records have them. Search scores a hit in those above
any position in the description, results show the title as a headline,
and each page puts it under the CVE id, in the browser title, the meta
description and an Affected row, with the block hubs listing it in place
of the description's opening.

The 35 MB metadata file the homepage needed before anything could be
filtered is split in two for the page: the CVSS rows load with the rest,
the advisories follow the index instead of competing with it for the
connection. cve_metadata.json stays whole for anyone reading the API.
2026-09-04 02:32:22 +02:00

2.1 KiB

CVE-2016-7165

Description

A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path ("C:\Program Files*" or the localized equivalent).

POC

Reference

Github

No PoCs found on GitHub currently.