"value":"After Junos OS device reboot or upgrade, the stateless firewall filter configuration may not take effect. This issue can be verified by running the command: user@re0> show interfaces <interface_name> extensive | match filters\" CAM destination filters: 0, CAM source filters: 0 Note: when the issue occurs, it does not show the applied firewall filter. The correct output should show the applied firewall filter, for example: user@re0> show interfaces <interface_name> extensive | match filters\" CAM destination filters: 0, CAM source filters: 0 Input Filters: FIREWAL_FILTER_NAME-<interface_name> This issue affects firewall filters for every address family. Affected releases are Juniper Networks Junos OS: 15.1R4, 15.1R5, 15.1R6 and SRs based on these MRs. 15.1X8 versions prior to 15.1X8.3."
"value":"The following software releases have been updated to resolve this specific issue: 15.1R7, 15.1X8.3 and all subsequent releases.\n"
}
],
"source":{
"advisory":"JSA10859",
"defect":[
"1161832"
],
"discovery":"USER"
},
"work_around":[
{
"lang":"eng",