cvelist/2021/25xxx/CVE-2021-25667.json

132 lines
5.6 KiB
JSON
Raw Normal View History

2021-01-26 18:02:03 +00:00
{
"CVE_data_meta": {
2021-03-09 12:55:18 +00:00
"ASSIGNER": "productcert@siemens.com",
2021-01-26 18:02:03 +00:00
"ID": "CVE-2021-25667",
2021-03-09 12:55:18 +00:00
"STATE": "PUBLIC"
},
"data_format": "MITRE",
"data_version": "4.0",
"data_type": "CVE",
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Siemens",
"product": {
"product_data": [
{
"product_name": "RUGGEDCOM RM1224",
"version": {
"version_data": [
{
"version_value": "All versions >= V4.3"
}
]
}
},
{
"product_name": "SCALANCE M-800",
"version": {
"version_data": [
{
"version_value": "All versions >= V4.3"
}
]
}
},
{
"product_name": "SCALANCE S615",
"version": {
"version_data": [
{
"version_value": "All versions >= V4.3"
}
]
}
},
{
"product_name": "SCALANCE SC-600 Family",
"version": {
"version_data": [
{
"version_value": "All versions >= V2.0 and < V2.1.3"
}
]
}
},
{
"product_name": "SCALANCE X300WG",
"version": {
"version_data": [
{
"version_value": "All versions < V4.1"
}
]
}
},
{
"product_name": "SCALANCE XM400",
"version": {
"version_data": [
{
"version_value": "All versions < V6.2"
}
]
}
},
{
"product_name": "SCALANCE XR500",
"version": {
"version_data": [
{
"version_value": "All versions < V6.2"
}
]
}
},
{
"product_name": "SCALANCE Xx200 Family",
"version": {
"version_data": [
{
"version_value": "All versions < V4.1"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121: Stack-based Buffer Overflow"
}
]
}
]
2021-01-26 18:02:03 +00:00
},
"description": {
"description_data": [
{
"lang": "eng",
2021-03-15 18:00:44 +00:00
"value": "A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3), SCALANCE M-800 (All versions >= V4.3), SCALANCE S615 (All versions >= V4.3), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE X300WG (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XR500 (All versions < V6.2), SCALANCE Xx200 Family (All versions < V4.1). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active."
2021-03-09 12:55:18 +00:00
}
]
},
"references": {
"reference_data": [
{
2021-03-15 18:00:44 +00:00
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf",
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf"
2021-01-26 18:02:03 +00:00
}
]
}
}