cvelist/2018/13xxx/CVE-2018-13802.json

73 lines
2.6 KiB
JSON
Raw Normal View History

2018-07-10 10:04:09 -04:00
{
2019-03-17 23:47:47 +00:00
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"DATE_PUBLIC": "2018-10-09T00:00:00",
"ID": "CVE-2018-13802",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ROX II",
"version": {
"version_data": [
{
"version_value": "All versions < V2.12.1"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
2019-03-17 23:47:47 +00:00
"lang": "eng",
"value": "A vulnerability has been identified in ROX II (All versions < V2.12.1). An authenticated attacker with a high-privileged user account access via SSH could circumvent restrictions in place and execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the SSH interface in on port 22/tcp. The attacker must be authenticated to exploit the vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device."
}
2019-03-17 23:47:47 +00:00
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-264: Permissions, Privileges, and Access Controls"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-282-03",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-282-03"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-493830.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-493830.pdf"
},
{
"name": "105545",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105545"
}
]
}
}