2022-11-21 10:00:33 +00:00
{
2023-03-14 10:00:37 +00:00
"data_version" : "4.0" ,
"data_type" : "CVE" ,
"data_format" : "MITRE" ,
2022-11-21 10:00:33 +00:00
"CVE_data_meta" : {
"ID" : "CVE-2022-45484" ,
2023-03-14 10:00:37 +00:00
"ASSIGNER" : "productcert@siemens.com" ,
2022-12-13 17:05:36 +01:00
"STATE" : "PUBLIC"
} ,
2023-03-14 10:00:37 +00:00
"description" : {
"description_data" : [
{
"lang" : "eng" ,
2023-04-11 10:00:36 +00:00
"value" : "A vulnerability has been identified in JT2Go (All versions < V14.1.0.6), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.9), Teamcenter Visualization V13.3 (All versions < V13.3.0.8), Teamcenter Visualization V14.0 (All versions < V14.0.0.5), Teamcenter Visualization V14.0 (All versions < V14.0.0.4), Teamcenter Visualization V14.1 (All versions < V14.1.0.6). The CCITT_G4Decode.dll contains an out of bounds read vulnerability when parsing a RAS file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19056)"
2023-03-14 10:00:37 +00:00
}
]
} ,
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng" ,
"value" : "CWE-125: Out-of-bounds Read" ,
"cweId" : "CWE-125"
}
]
}
]
} ,
2022-12-13 17:05:36 +01:00
"affects" : {
"vendor" : {
"vendor_data" : [
{
"vendor_name" : "Siemens" ,
"product" : {
"product_data" : [
{
"product_name" : "JT2Go" ,
"version" : {
"version_data" : [
{
2023-03-14 10:00:37 +00:00
"version_affected" : "=" ,
2023-04-11 10:00:36 +00:00
"version_value" : "All versions < V14.1.0.6"
2022-12-13 17:05:36 +01:00
}
]
}
} ,
{
"product_name" : "Teamcenter Visualization V13.2" ,
"version" : {
"version_data" : [
{
2023-03-14 10:00:37 +00:00
"version_affected" : "=" ,
2022-12-13 17:05:36 +01:00
"version_value" : "All versions < V13.2.0.12"
}
]
}
} ,
{
"product_name" : "Teamcenter Visualization V13.3" ,
"version" : {
"version_data" : [
{
2023-03-14 10:00:37 +00:00
"version_affected" : "=" ,
"version_value" : "All versions < V13.3.0.9"
} ,
2022-12-13 17:05:36 +01:00
{
2023-03-14 10:00:37 +00:00
"version_affected" : "=" ,
"version_value" : "All versions < V13.3.0.8"
2022-12-13 17:05:36 +01:00
}
]
}
} ,
{
"product_name" : "Teamcenter Visualization V14.0" ,
"version" : {
"version_data" : [
{
2023-03-14 10:00:37 +00:00
"version_affected" : "=" ,
"version_value" : "All versions < V14.0.0.5"
} ,
2022-12-13 17:05:36 +01:00
{
2023-03-14 10:00:37 +00:00
"version_affected" : "=" ,
"version_value" : "All versions < V14.0.0.4"
2022-12-13 17:05:36 +01:00
}
]
}
} ,
{
"product_name" : "Teamcenter Visualization V14.1" ,
"version" : {
"version_data" : [
{
2023-03-14 10:00:37 +00:00
"version_affected" : "=" ,
2022-12-13 17:05:36 +01:00
"version_value" : "All versions < V14.1.0.6"
}
]
}
}
]
}
}
]
}
} ,
"references" : {
"reference_data" : [
{
2022-12-13 17:00:41 +00:00
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf" ,
2023-03-14 10:00:37 +00:00
"refsource" : "MISC" ,
2022-12-13 17:00:41 +00:00
"name" : "https://cert-portal.siemens.com/productcert/pdf/ssa-700053.pdf"
2022-11-21 10:00:33 +00:00
}
]
2023-03-14 10:00:37 +00:00
} ,
"impact" : {
"cvss" : [
{
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C" ,
"baseScore" : 3.3 ,
"baseSeverity" : "LOW"
}
]
2022-11-21 10:00:33 +00:00
}
}