2023-11-15 02:00:37 +00:00
{
2023-11-16 08:00:34 +00:00
"data_version" : "4.0" ,
2023-11-15 02:00:37 +00:00
"data_type" : "CVE" ,
"data_format" : "MITRE" ,
"CVE_data_meta" : {
"ID" : "CVE-2023-47674" ,
2023-11-16 08:00:34 +00:00
"ASSIGNER" : "vultures@jpcert.or.jp" ,
"STATE" : "PUBLIC"
2023-11-15 02:00:37 +00:00
} ,
"description" : {
"description_data" : [
{
"lang" : "eng" ,
2023-11-16 08:00:34 +00:00
"value" : "Missing authentication for critical function vulnerability in First Corporation's DVRs allows a remote unauthenticated attacker to rewrite or obtain the configuration information of the affected device. Note that updates are provided only for Late model of CFR-4EABC, CFR-4EAB, CFR-8EAB, CFR-16EAB, MD-404AB, and MD-808AB. As for the other products, apply the workaround."
}
]
} ,
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng" ,
"value" : "Missing authentication for critical function"
}
]
}
]
} ,
"affects" : {
"vendor" : {
"vendor_data" : [
{
"vendor_name" : "First Co., Ltd." ,
"product" : {
"product_data" : [
{
"product_name" : "CFR-904E, CFR-908E, CFR-916E" ,
"version" : {
"version_data" : [
{
"version_affected" : "=" ,
"version_value" : "firmware all versions"
}
]
}
} ,
{
"product_name" : "CFR-4EHD, CFR-8EHD, CFR-16EHD" ,
"version" : {
"version_data" : [
{
"version_affected" : "=" ,
"version_value" : "firmware all versions"
}
]
}
} ,
{
"product_name" : "CFR-4EHA, CFR-8EHA, CFR-16EHA" ,
"version" : {
"version_data" : [
{
"version_affected" : "=" ,
"version_value" : "firmware all versions"
}
]
}
} ,
{
"product_name" : "CFR-4EAAM, CFR-4EABC" ,
"version" : {
"version_data" : [
{
"version_affected" : "=" ,
"version_value" : "firmware all versions"
}
]
}
} ,
{
"product_name" : "CFR-4EAA, CFR-8EAA, CFR-16EAA" ,
"version" : {
"version_data" : [
{
"version_affected" : "=" ,
"version_value" : "firmware all versions"
}
]
}
} ,
{
"product_name" : "CFR-4EAB, CFR-8EAB, CFR-16EAB" ,
"version" : {
"version_data" : [
{
"version_affected" : "=" ,
"version_value" : "firmware all versions"
}
]
}
} ,
{
"product_name" : "CFR-1004EA, CFR-1008EA, CFR-1016EA" ,
"version" : {
"version_data" : [
{
"version_affected" : "=" ,
"version_value" : "firmware all versions"
}
]
}
} ,
{
"product_name" : "MD-404HD, MD-808HD" ,
"version" : {
"version_data" : [
{
"version_affected" : "=" ,
"version_value" : "firmware all versions"
}
]
}
} ,
{
"product_name" : "MD-404HA, MD-808HA" ,
"version" : {
"version_data" : [
{
"version_affected" : "=" ,
"version_value" : "firmware all versions"
}
]
}
} ,
{
"product_name" : "MD-404AA, MD-808AA" ,
"version" : {
"version_data" : [
{
"version_affected" : "=" ,
"version_value" : "firmware all versions"
}
]
}
} ,
{
"product_name" : "MD-404AB, MD-808AB" ,
"version" : {
"version_data" : [
{
"version_affected" : "=" ,
"version_value" : "firmware all versions"
}
]
}
}
]
}
}
]
}
} ,
"references" : {
"reference_data" : [
{
"url" : "https://www.c-first.co.jp/information/ddososhirase/" ,
"refsource" : "MISC" ,
"name" : "https://www.c-first.co.jp/information/ddososhirase/"
} ,
{
"url" : "https://www.c-first.co.jp/wp/wp-content/uploads/2023/11/tuushin.pdf" ,
"refsource" : "MISC" ,
"name" : "https://www.c-first.co.jp/wp/wp-content/uploads/2023/11/tuushin.pdf"
} ,
{
"url" : "https://jvn.jp/en/vu/JVNVU99077347/" ,
"refsource" : "MISC" ,
"name" : "https://jvn.jp/en/vu/JVNVU99077347/"
2023-11-15 02:00:37 +00:00
}
]
}
}