2023-07-17 14:00:32 +00:00
{
2023-09-12 20:00:34 +00:00
"data_version" : "4.0" ,
2023-07-17 14:00:32 +00:00
"data_type" : "CVE" ,
"data_format" : "MITRE" ,
"CVE_data_meta" : {
"ID" : "CVE-2023-3710" ,
2023-09-12 20:00:34 +00:00
"ASSIGNER" : "psirt@honeywell.com" ,
"STATE" : "PUBLIC"
2023-07-17 14:00:32 +00:00
} ,
"description" : {
"description_data" : [
{
"lang" : "eng" ,
2023-09-12 20:00:34 +00:00
"value" : "Improper Input Validation vulnerability in Honeywell PM43 on 32 bit, ARM (Printer web page modules) allows Command Injection.This issue affects PM43 versions prior to P10.19.050004.\u00a0Update to the latest available firmware version of the respective printers to version MR19.5 (e.g. P10.19.050006).\n\n"
}
]
} ,
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng" ,
"value" : "CWE-20 Improper Input Validation" ,
"cweId" : "CWE-20"
}
]
}
]
} ,
"affects" : {
"vendor" : {
"vendor_data" : [
{
"vendor_name" : "Honeywell" ,
"product" : {
"product_data" : [
{
"product_name" : "PM23/43" ,
"version" : {
"version_data" : [
{
"version_affected" : "<" ,
"version_name" : "0" ,
"version_value" : "P10.19.050004"
}
]
}
} ,
{
"product_name" : "PM42" ,
"version" : {
"version_data" : [
{
"version_affected" : "<" ,
"version_name" : "0" ,
"version_value" : "T10.19.050004"
}
]
}
} ,
{
"product_name" : "PX4ie/6ie" ,
"version" : {
"version_data" : [
{
"version_affected" : "<" ,
"version_name" : "0" ,
"version_value" : "A10.19.050004"
}
]
}
} ,
{
"product_name" : "PX45/65" ,
"version" : {
"version_data" : [
{
"version_affected" : "<" ,
"version_name" : "0" ,
"version_value" : "B10.19.050004"
}
]
}
} ,
{
"product_name" : "PD45, PX240" ,
"version" : {
"version_data" : [
{
"version_affected" : "<" ,
"version_name" : "0" ,
"version_value" : "F10.19.050004"
}
]
}
} ,
{
"product_name" : "PX940" ,
"version" : {
"version_data" : [
{
"version_affected" : "<" ,
"version_name" : "0" ,
"version_value" : "H10.19.050004"
}
]
}
} ,
{
"product_name" : "PM45" ,
"version" : {
"version_data" : [
{
"version_affected" : "<" ,
"version_name" : "0" ,
"version_value" : "J10.19.050004"
}
]
}
} ,
{
"product_name" : "RP2f/RP4f" ,
"version" : {
"version_data" : [
{
"version_affected" : "<" ,
"version_name" : "0" ,
"version_value" : "M10.19.050006"
}
]
}
}
]
}
} ,
{
"vendor_name" : "Honeywell " ,
"product" : {
"product_data" : [
{
"product_name" : "PC23/43, PD43" ,
"version" : {
"version_data" : [
{
"version_affected" : "<" ,
"version_name" : "0" ,
"version_value" : "K10.19.050004"
}
]
}
}
]
}
}
]
}
} ,
"references" : {
"reference_data" : [
{
"url" : "https://www.honeywell.com/us/en/product-security" ,
"refsource" : "MISC" ,
"name" : "https://www.honeywell.com/us/en/product-security"
} ,
{
"url" : "https://hsmftp.honeywell.com:443/en/Software/Printers/Industrial/PM23-PM23c-PM43-PM43c/Current/Firmware/firmwaresignedP1019050004" ,
"refsource" : "MISC" ,
"name" : "https://hsmftp.honeywell.com:443/en/Software/Printers/Industrial/PM23-PM23c-PM43-PM43c/Current/Firmware/firmwaresignedP1019050004"
} ,
{
"url" : "https://hsmftp.honeywell.com:443/en/Software/Printers/Industrial/PM23-PM23c-PM43-PM43c/Current/Firmware/firmwarexasignedP1019050004A" ,
"refsource" : "MISC" ,
"name" : "https://hsmftp.honeywell.com:443/en/Software/Printers/Industrial/PM23-PM23c-PM43-PM43c/Current/Firmware/firmwarexasignedP1019050004A"
}
]
} ,
"generator" : {
"engine" : "Vulnogram 0.1.0-dev"
} ,
"source" : {
"discovery" : "EXTERNAL"
} ,
"impact" : {
"cvss" : [
{
"attackComplexity" : "LOW" ,
"attackVector" : "NETWORK" ,
"availabilityImpact" : "HIGH" ,
"baseScore" : 9.9 ,
"baseSeverity" : "CRITICAL" ,
"confidentialityImpact" : "LOW" ,
"integrityImpact" : "LOW" ,
"privilegesRequired" : "NONE" ,
"scope" : "CHANGED" ,
"userInteraction" : "NONE" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:H" ,
"version" : "3.1"
2023-07-17 14:00:32 +00:00
}
]
}
}