2024-02-01 16:00:33 +00:00
{
2024-02-13 10:00:33 +00:00
"data_version" : "4.0" ,
2024-02-01 16:00:33 +00:00
"data_type" : "CVE" ,
"data_format" : "MITRE" ,
"CVE_data_meta" : {
"ID" : "CVE-2024-24922" ,
2024-02-13 10:00:33 +00:00
"ASSIGNER" : "productcert@siemens.com" ,
"STATE" : "PUBLIC"
2024-02-01 16:00:33 +00:00
} ,
"description" : {
"description_data" : [
{
"lang" : "eng" ,
2024-02-13 10:00:33 +00:00
"value" : "A vulnerability has been identified in Simcenter Femap (All versions < V2401.0000). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted Catia MODEL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21715)"
}
]
} ,
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng" ,
"value" : "CWE-787: Out-of-bounds Write" ,
"cweId" : "CWE-787"
}
]
}
]
} ,
"affects" : {
"vendor" : {
"vendor_data" : [
{
"vendor_name" : "Siemens" ,
"product" : {
"product_data" : [
{
"product_name" : "Simcenter Femap" ,
"version" : {
"version_data" : [
{
"version_affected" : "<" ,
"version_name" : "0" ,
"version_value" : "V2401.0000"
}
]
}
}
]
}
}
]
}
} ,
"references" : {
"reference_data" : [
{
"url" : "https://cert-portal.siemens.com/productcert/html/ssa-000072.html" ,
"refsource" : "MISC" ,
"name" : "https://cert-portal.siemens.com/productcert/html/ssa-000072.html"
}
]
} ,
"impact" : {
"cvss" : [
{
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C" ,
"baseScore" : 7.8 ,
"baseSeverity" : "HIGH"
2024-02-01 16:00:33 +00:00
}
]
}
}