"value":"\nA specific malformed fragmented packet type (fragmented packets may be generated automatically by devices that send large amounts of data) can cause a major nonrecoverable fault (MNRF) Rockwell Automation's ControlLogix 5580, Guard Logix\u00a05580,\u00a0CompactLogix 5380,\u00a0and 1756-EN4TR. If exploited, the affected product will become unavailable and require a manual restart to recover it. Additionally, an MNRF could result in a loss of view and/or control of connected devices. \n\n"
"value":"\n\n<p>\n\n</p><table><tbody><tr><td><p><br>Affected Product</p><p> </p><p> </p></td><td><p> </p><p> </p><p>First Known in Firmware Revision</p><p> </p><p> </p></td><td><p> </p><p> </p><p>Corrected in Firmware Revision</p><p> </p><p> </p></td></tr><tr><td><p> </p><p> </p><p>ControlLogix\u00ae 5580</p><p> </p><p> </p></td><td><p> </p><p> </p><p>V35.011</p><p> </p><p> </p></td><td><p> </p><p> </p><p>V35.013, V36.011</p><p> </p><p> </p></td></tr><tr><td><p> </p><p> </p><p>GuardLogix 5580</p><p> </p><p> </p></td><td><p> </p><p> </p><p>V35.011</p><p> </p><p> </p></td><td><p> </p><p> </p><p>V35.013, V36.011</p><p> </p><p> </p></td></tr><tr><td><p> </p><p> </p><p>CompactLogix 5380</p><p> </p><p> </p></td><td><p> </p><p> </p><p>V35.011</p><p> </p><p> </p></td><td><p> </p><p> </p><p>V35.013, V36.011</p><p> </p><p> </p></td></tr><tr><td><p> </p><p> </p><p>1756-EN4TR</p><p> </p><p> </p></td><td><p> </p><p> </p><p>V5.001</p><p> </p><p> </p></td><td><p> </p><p> </p><p>V6.001</p><p> </p><p> </p></td></tr></tbody></table>\n\n<br><br><p></p><p>Users using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices, where possible.\u202f\u202f</p><ul><li><p><a target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">Security Best Practices</a> </p></li></ul>\n\n<br>"
}
],
"value":"\nAffected Product\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nFirst Known in Firmware Revision\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCorrected in Firmware Revision\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nControlLogix\u00ae 5580\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nV35.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nV35.013, V36.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nGuardLogix 5580\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nV35.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nV35.013, V36.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCompactLogix 5380\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nV35.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nV35.013, V36.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n1756-EN4TR\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nV5.001\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nV6.001\n\n\u00a0\n\n\u00a0\n\nUsers using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices, where possible.\u202f\u202f\n\n * Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight \u00a0\n\n"