2019-11-26 15:02:09 +00:00
{
"CVE_data_meta" : {
2020-03-10 10:48:41 +01:00
"ASSIGNER" : "productcert@siemens.com" ,
2019-11-26 15:02:09 +00:00
"ID" : "CVE-2019-19277" ,
2020-03-10 10:48:41 +01:00
"STATE" : "PUBLIC"
} ,
"data_format" : "MITRE" ,
"data_version" : "4.0" ,
"data_type" : "CVE" ,
"affects" : {
"vendor" : {
"vendor_data" : [
{
"vendor_name" : "Siemens AG" ,
"product" : {
"product_data" : [
{
"product_name" : "SIPORT MP" ,
"version" : {
"version_data" : [
{
"version_value" : "All versions < 3.1.4"
}
]
}
}
]
}
}
]
}
} ,
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng" ,
"value" : "CWE-778: Insufficient Logging"
}
]
}
]
2019-11-26 15:02:09 +00:00
} ,
"description" : {
"description_data" : [
{
"lang" : "eng" ,
2020-03-10 20:01:23 +00:00
"value" : "A vulnerability has been identified in SIPORT MP (All versions < 3.1.4). Vulnerable versions of the device allow the creation of special accounts (\"service users\") with administrative privileges that could enable a remote authenticated attacker to perform actions that are not visible to other users of the system, such as granting persons access to a secured area."
2020-03-10 10:48:41 +01:00
}
]
} ,
"references" : {
"reference_data" : [
{
2020-03-10 20:01:23 +00:00
"refsource" : "MISC" ,
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-978558.pdf" ,
"name" : "https://cert-portal.siemens.com/productcert/pdf/ssa-978558.pdf"
2020-03-30 18:01:16 +00:00
} ,
{
"refsource" : "MISC" ,
"name" : "https://www.us-cert.gov/ics/advisories/icsa-20-042-08" ,
"url" : "https://www.us-cert.gov/ics/advisories/icsa-20-042-08"
2019-11-26 15:02:09 +00:00
}
]
}
}