2017-10-16 12:31:07 -04:00
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org" ,
"ID" : "CVE-2012-4698" ,
"STATE" : "PUBLIC"
} ,
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "n/a" ,
"version" : {
"version_data" : [
{
"version_value" : "n/a"
}
]
}
}
]
} ,
"vendor_name" : "n/a"
}
]
}
} ,
"data_format" : "MITRE" ,
"data_type" : "CVE" ,
"data_version" : "4.0" ,
"description" : {
"description_data" : [
{
"lang" : "eng" ,
"value" : "Siemens RuggedCom Rugged Operating System (ROS) before 3.12, ROX I OS through 1.14.5, ROX II OS through 2.3.0, and RuggedMax OS through 4.2.1.4621.22 use hardcoded private keys for SSL and SSH communication, which makes it easier for man-in-the-middle attackers to spoof servers and decrypt network traffic by leveraging the availability of these keys within ROS files at all customer installations."
}
]
} ,
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng" ,
"value" : "n/a"
}
]
}
]
} ,
"references" : {
"reference_data" : [
{
2018-04-05 09:33:01 -04:00
"name" : "http://www.us-cert.gov/control_systems/pdf/ICSA-12-354-01.pdf" ,
"refsource" : "MISC" ,
2017-10-16 12:31:07 -04:00
"url" : "http://www.us-cert.gov/control_systems/pdf/ICSA-12-354-01.pdf"
} ,
{
2018-04-05 09:33:01 -04:00
"name" : "http://ics-cert.us-cert.gov/advisories/ICSA-12-354-01A" ,
"refsource" : "MISC" ,
2017-10-16 12:31:07 -04:00
"url" : "http://ics-cert.us-cert.gov/advisories/ICSA-12-354-01A"
} ,
{
2018-04-05 09:33:01 -04:00
"name" : "http://www.ruggedcom.com/productbulletin/ros-security-page/" ,
"refsource" : "CONFIRM" ,
2017-10-16 12:31:07 -04:00
"url" : "http://www.ruggedcom.com/productbulletin/ros-security-page/"
} ,
{
2018-04-05 09:33:01 -04:00
"name" : "https://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-622607.pdf" ,
"refsource" : "CONFIRM" ,
2017-10-16 12:31:07 -04:00
"url" : "https://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-622607.pdf"
}
]
}
}