"value":"In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550\n\n"
}
]
},
"problemtype":{
"problemtype_data":[
{
"description":[
{
"lang":"eng",
"value":"CWE-20 Improper Input Validation",
"cweId":"CWE-20"
}
]
}
]
},
"affects":{
"vendor":{
"vendor_data":[
{
"vendor_name":"CODESYS",
"product":{
"product_data":[
{
"product_name":"CODESYS Control for BeagleBone SL",
"version":{
"version_data":[
{
"version_affected":"<",
"version_name":"0",
"version_value":"V4.10.0.0"
}
]
}
},
{
"product_name":"CODESYS Control for emPC-A/iMX6 SL",
"version":{
"version_data":[
{
"version_affected":"<",
"version_name":"0",
"version_value":"V4.10.0.0"
}
]
}
},
{
"product_name":"CODESYS Control for IOT2000 SL",
"version":{
"version_data":[
{
"version_affected":"<",
"version_name":"0",
"version_value":"V4.10.0.0"
}
]
}
},
{
"product_name":"CODESYS Control for Linux SL",
"version":{
"version_data":[
{
"version_affected":"<",
"version_name":"0",
"version_value":"V4.10.0.0"
}
]
}
},
{
"product_name":"CODESYS Control for PFC100 SL",
"version":{
"version_data":[
{
"version_affected":"<",
"version_name":"0",
"version_value":"V4.10.0.0"
}
]
}
},
{
"product_name":"CODESYS Control for PFC200 SL",
"version":{
"version_data":[
{
"version_affected":"<",
"version_name":"0",
"version_value":"V4.10.0.0"
}
]
}
},
{
"product_name":"CODESYS Control for PLCnext SL",
"version":{
"version_data":[
{
"version_affected":"<",
"version_name":"0",
"version_value":"V4.10.0.0"
}
]
}
},
{
"product_name":"CODESYS Control for Raspberry Pi SL",
"version":{
"version_data":[
{
"version_affected":"<",
"version_name":"0",
"version_value":"V4.10.0.0"
}
]
}
},
{
"product_name":"CODESYS Control for WAGO Touch Panels 600 SL",
"version":{
"version_data":[
{
"version_affected":"<",
"version_name":"0",
"version_value":"V4.10.0.0"
}
]
}
},
{
"product_name":"CODESYS Control RTE (for Beckhoff CX) SL",
"version":{
"version_data":[
{
"version_affected":"<",
"version_name":"0",
"version_value":"V3.5.19.20"
}
]
}
},
{
"product_name":"CODESYS Control RTE (SL)",
"version":{
"version_data":[
{
"version_affected":"<",
"version_name":"0",
"version_value":"V3.5.19.20"
}
]
}
},
{
"product_name":"CODESYS Control Runtime System Toolkit",