2023-04-25 00:00:37 +00:00
{
2023-11-30 17:00:33 +00:00
"data_version" : "4.0" ,
2023-04-25 00:00:37 +00:00
"data_type" : "CVE" ,
"data_format" : "MITRE" ,
"CVE_data_meta" : {
"ID" : "CVE-2023-2266" ,
2023-11-30 17:00:33 +00:00
"ASSIGNER" : "security@selinc.com" ,
"STATE" : "PUBLIC"
2023-04-25 00:00:37 +00:00
} ,
"description" : {
"description_data" : [
{
"lang" : "eng" ,
2023-11-30 17:00:33 +00:00
"value" : "An\u00a0Improper neutralization of input during web page generation in the Schweitzer Engineering Laboratories SEL-411L\u00a0could allow an attacker to generate cross-site scripting based attacks against an authorized and authenticated user.\n\n\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\n"
}
]
} ,
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng" ,
"value" : "CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')" ,
"cweId" : "CWE-79"
}
]
}
]
} ,
"affects" : {
"vendor" : {
"vendor_data" : [
{
"vendor_name" : "Schweitzer Engineering Laboratories" ,
"product" : {
"product_data" : [
{
"product_name" : "SEL-411L" ,
"version" : {
"version_data" : [
{
"version_affected" : "<" ,
"version_name" : "R118-V0" ,
"version_value" : "R118-V4"
} ,
{
"version_affected" : "<" ,
"version_name" : "R119-V0" ,
"version_value" : "R119-V5"
} ,
{
"version_affected" : "<" ,
"version_name" : "R120-V0" ,
"version_value" : "R120-V6"
} ,
{
"version_affected" : "<" ,
"version_name" : "R121-V0" ,
"version_value" : "R121-V3"
} ,
{
"version_affected" : "<" ,
"version_name" : "R122-V0" ,
"version_value" : "R122-V3"
} ,
{
"version_affected" : "<" ,
"version_name" : "R123-V0" ,
"version_value" : "R123-V3"
} ,
{
"version_affected" : "<" ,
"version_name" : "R124-V0" ,
"version_value" : "R124-V3"
} ,
{
"version_affected" : "<" ,
"version_name" : "R125-V0" ,
"version_value" : "R125-V3"
} ,
{
"version_affected" : "<" ,
"version_name" : "R126-V0" ,
"version_value" : "R126-V4"
} ,
{
"version_affected" : "<" ,
"version_name" : "R127-V0" ,
"version_value" : "R127-V2"
} ,
{
"version_affected" : "<" ,
"version_name" : "R128-V0" ,
"version_value" : "R128-V1"
} ,
{
"version_affected" : "<" ,
"version_name" : "R129-V0" ,
"version_value" : "R129-V1"
}
]
}
}
]
}
}
]
}
} ,
"references" : {
"reference_data" : [
{
"url" : "https://selinc.com/support/security-notifications/external-reports/" ,
"refsource" : "MISC" ,
"name" : "https://selinc.com/support/security-notifications/external-reports/"
}
]
} ,
"generator" : {
"engine" : "Vulnogram 0.1.0-dev"
} ,
"source" : {
"discovery" : "UNKNOWN"
} ,
"credits" : [
{
"lang" : "en" ,
"value" : "Sushant Mane, Parul Sindhwad, Imran Jamadar & Dr. Faruk Kazi from CoE-CNDS Lab, VJTI, Mumbai, India."
}
] ,
"impact" : {
"cvss" : [
{
"attackComplexity" : "LOW" ,
"attackVector" : "NETWORK" ,
"availabilityImpact" : "NONE" ,
"baseScore" : 4.3 ,
"baseSeverity" : "MEDIUM" ,
"confidentialityImpact" : "LOW" ,
"integrityImpact" : "NONE" ,
"privilegesRequired" : "NONE" ,
"scope" : "UNCHANGED" ,
"userInteraction" : "REQUIRED" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" ,
"version" : "3.1"
2023-04-25 00:00:37 +00:00
}
]
}
}