cvelist/2023/30xxx/CVE-2023-30899.json

151 lines
6.6 KiB
JSON
Raw Normal View History

2023-04-20 13:00:36 +00:00
{
2023-05-09 12:00:35 +00:00
"data_version": "4.0",
2023-04-20 13:00:36 +00:00
"data_type": "CVE",
"data_format": "MITRE",
"CVE_data_meta": {
"ID": "CVE-2023-30899",
2023-05-09 12:00:35 +00:00
"ASSIGNER": "productcert@siemens.com",
"STATE": "PUBLIC"
2023-04-20 13:00:36 +00:00
},
"description": {
"description_data": [
{
"lang": "eng",
2023-05-09 12:00:35 +00:00
"value": "A vulnerability has been identified in Siveillance Video 2020 R2 (All versions < V20.2 HotfixRev14), Siveillance Video 2020 R3 (All versions < V20.3 HotfixRev12), Siveillance Video 2021 R1 (All versions < V21.1 HotfixRev12), Siveillance Video 2021 R2 (All versions < V21.2 HotfixRev8), Siveillance Video 2022 R1 (All versions < V22.1 HotfixRev7), Siveillance Video 2022 R2 (All versions < V22.2 HotfixRev5), Siveillance Video 2022 R3 (All versions < V22.3 HotfixRev2), Siveillance Video 2023 R1 (All versions < V23.1 HotfixRev1). The Management Server component of affected applications deserializes data without sufficient validations. This could allow an authenticated remote attacker to execute code on the affected system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-502: Deserialization of Untrusted Data",
"cweId": "CWE-502"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Siemens",
"product": {
"product_data": [
{
"product_name": "Siveillance Video 2020 R2",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions < V20.2 HotfixRev14"
}
]
}
},
{
"product_name": "Siveillance Video 2020 R3",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions < V20.3 HotfixRev12"
}
]
}
},
{
"product_name": "Siveillance Video 2021 R1",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions < V21.1 HotfixRev12"
}
]
}
},
{
"product_name": "Siveillance Video 2021 R2",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions < V21.2 HotfixRev8"
}
]
}
},
{
"product_name": "Siveillance Video 2022 R1",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions < V22.1 HotfixRev7"
}
]
}
},
{
"product_name": "Siveillance Video 2022 R2",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions < V22.2 HotfixRev5"
}
]
}
},
{
"product_name": "Siveillance Video 2022 R3",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions < V22.3 HotfixRev2"
}
]
}
},
{
"product_name": "Siveillance Video 2023 R1",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions < V23.1 HotfixRev1"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789345.pdf",
"refsource": "MISC",
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-789345.pdf"
}
]
},
"impact": {
"cvss": [
{
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"baseScore": 9.9,
"baseSeverity": "CRITICAL"
2023-04-20 13:00:36 +00:00
}
]
}
}