"-Synchronized-Data."

This commit is contained in:
CVE Team 2023-06-20 17:00:40 +00:00
parent 758cdcd3bc
commit 07ae157bd5
No known key found for this signature in database
GPG Key ID: E3252B3D49582C98
4 changed files with 297 additions and 141 deletions

View File

@ -1,25 +1,96 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2019-10952",
"ASSIGNER": "ics-cert@hq.dhs.gov",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "\n\n\nAn attacker could send a crafted HTTP/HTTPS request to render the web server unavailable and/or lead to remote code execution caused by a stack-based buffer overflow vulnerability. A cold restart is required for recovering \n\nCompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers Versions 20 - 30 and earlier.\n\n"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400 Uncontrolled Resource Consumption",
"cweId": "CWE-400"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "CompactLogix",
"vendor_name": "Rockwell Automation",
"product": {
"product_data": [
{
"product_name": "CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers",
"product_name": "CompactLogix 5370 L1 controllers",
"version": {
"version_data": [
{
"version_value": "Versions 20 to 30.014 and earlier"
"version_affected": "<",
"version_name": "0",
"version_value": "20 - 30"
}
]
}
},
{
"product_name": "CompactLogix 5370 L2 controllers",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "0",
"version_value": "20 - 30"
}
]
}
},
{
"product_name": "CompactLogix 5370 L3 controllers",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "0",
"version_value": "20 - 30"
}
]
}
},
{
"product_name": "Compact GuardLogix 5370 controllers",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "0",
"version_value": "20 - 30"
}
]
}
},
{
"product_name": "Armor Compact GuardLogix 5370 controllers",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "0",
"version_value": "20 - 30"
}
]
}
@ -30,38 +101,48 @@
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "UNCONTROLLED RESOURCE CONSUMPTION CWE-400"
}
]
}
]
},
"references": {
"reference_data": [
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-120-01",
"refsource": "MISC",
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-120-01",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-120-01"
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-120-01"
},
{
"refsource": "BID",
"name": "108118",
"url": "http://www.securityfocus.com/bid/108118"
"url": "http://www.securityfocus.com/bid/108118",
"refsource": "MISC",
"name": "http://www.securityfocus.com/bid/108118"
},
{
"url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1075979",
"refsource": "MISC",
"name": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1075979"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "An attacker could send a crafted HTTP/HTTPS request to render the web server unavailable and/or lead to remote code execution caused by a stack-based buffer overflow vulnerability. A cold restart is required for recovering CompactLogix 5370 L1, L2, and L3 Controllers, Compact GuardLogix 5370 controllers, and Armor Compact GuardLogix 5370 Controllers Versions 20 to 30.014 and earlier systems."
}
]
}
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "EXTERNAL"
},
"solution": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n<p></p>Rockwell Automation strongly encourages users to apply the latest available version of firmware to keep up to date with the latest features, anomaly fixes, and security improvements. Update firmware to version FRN 31.011 that mitigates the associated risk.<br><br>Rockwell Automation also recommends the following:<br><p><a target=\"_blank\" rel=\"nofollow\" href=\"https://compatibility.rockwellautomation.com/Pages/MultiProductDownload.aspx?Keyword=5370&amp;crumb=112%C2%A0\"> </a></p><ul><li>For EtherNet/IP-based vulnerabilities (ID 1-14), block all traffic to and from outside the Manufacturing Zone by blocking or restricting access to Port 2222/TCP/UDP and Port 44818/TCP/UDP using proper network infrastructure controls, such as firewalls, UTM devices, or other security appliances. For more information on TCP/UDP ports used by Rockwell Automation Products, see Knowledgebase Article ID <a target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/898270/page/1\">898270</a>&nbsp;(login required).<ul><li>Stratix users can use Device Manager or Studio 5000 Logix Designer to configure access control lists (ACL) to block/restrict ports. See section \u201cAccess Control Lists\u201d in <a target=\"_blank\" rel=\"nofollow\" href=\"http://literature.rockwellautomation.com/idc/groups/literature/documents/um/1783-um007_-en-p.pdf\">Stratix Managed Switches User Manual, publication 1783-UM007</a>, for detailed instructions.</li></ul></li><li>For web-based vulnerabilities (ID 15-17), block all traffic from outside the Manufacturing Zone by blocking or restricting access to Port 80/443/TCP.<ul><li>Stratix users can use Device Manager or Studio 5000 Logix Designer to configure ACL\u2019s to block/restrict ports. See section \u201cAccess Control Lists\u201d in <a target=\"_blank\" rel=\"nofollow\" href=\"http://literature.rockwellautomation.com/idc/groups/literature/documents/um/1783-um007_-en-p.pdf\">Stratix Managed Switches User Manual, publication 1783-UM007</a>, for detailed instructions.</li></ul></li><li>Utilize proper network infrastructure controls, such as firewalls, to help ensure that SMTP packets from unauthorized sources are blocked.</li><li>Consult the product documentation for specific features, such as a hardware key-switch setting, which may be used to block unauthorized changes, etc.</li><li>Use trusted software, software patches, and antivirus/antimalware programs and interact only with trusted websites and attachments.</li><li>Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet. For further information about the risks of unprotected Internet accessible control systems, please see Knowledgebase Article ID <a target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/494865/page/1\">494865</a>&nbsp;(login required).</li><li>When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that a VPN is only as secure as the connected devices.</li></ul><p>For more information please refer to Rockwell\u2019s Security Advisory: <a target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1075979\">https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1075979</a></p>\n\n<br>"
}
],
"value": "\n\n\nRockwell Automation strongly encourages users to apply the latest available version of firmware to keep up to date with the latest features, anomaly fixes, and security improvements. Update firmware to version FRN 31.011 that mitigates the associated risk.\n\nRockwell Automation also recommends the following:\n https://compatibility.rockwellautomation.com/Pages/MultiProductDownload.aspx \n\n * For EtherNet/IP-based vulnerabilities (ID 1-14), block all traffic to and from outside the Manufacturing Zone by blocking or restricting access to Port 2222/TCP/UDP and Port 44818/TCP/UDP using proper network infrastructure controls, such as firewalls, UTM devices, or other security appliances. For more information on TCP/UDP ports used by Rockwell Automation Products, see Knowledgebase Article ID 898270 https://rockwellautomation.custhelp.com/app/answers/detail/a_id/898270/page/1 \u00a0(login required). * Stratix users can use Device Manager or Studio 5000 Logix Designer to configure access control lists (ACL) to block/restrict ports. See section \u201cAccess Control Lists\u201d in Stratix Managed Switches User Manual, publication 1783-UM007 http://literature.rockwellautomation.com/idc/groups/literature/documents/um/1783-um007_-en-p.pdf , for detailed instructions.\n\n\n\n * For web-based vulnerabilities (ID 15-17), block all traffic from outside the Manufacturing Zone by blocking or restricting access to Port 80/443/TCP. * Stratix users can use Device Manager or Studio 5000 Logix Designer to configure ACL\u2019s to block/restrict ports. See section \u201cAccess Control Lists\u201d in Stratix Managed Switches User Manual, publication 1783-UM007 http://literature.rockwellautomation.com/idc/groups/literature/documents/um/1783-um007_-en-p.pdf , for detailed instructions.\n\n\n\n * Utilize proper network infrastructure controls, such as firewalls, to help ensure that SMTP packets from unauthorized sources are blocked.\n * Consult the product documentation for specific features, such as a hardware key-switch setting, which may be used to block unauthorized changes, etc.\n * Use trusted software, software patches, and antivirus/antimalware programs and interact only with trusted websites and attachments.\n * Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet. For further information about the risks of unprotected Internet accessible control systems, please see Knowledgebase Article ID 494865 https://rockwellautomation.custhelp.com/app/answers/detail/a_id/494865/page/1 \u00a0(login required).\n * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that a VPN is only as secure as the connected devices.\n\n\nFor more information please refer to Rockwell\u2019s Security Advisory: https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1075979 https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1075979 \n\n\n\n\n"
}
],
"credits": [
{
"lang": "en",
"value": "Younes Dragoni of Nozomi Networks of CyberX reported to CISA."
}
]
}

View File

@ -1,114 +1,119 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"generator": {
"engine": "Vulnogram 0.0.9"
},
"CVE_data_meta": {
"ID": "CVE-2021-32837",
"ASSIGNER": "security-advisories@github.com",
"DATE_PUBLIC": "",
"TITLE": "mechanize vulnerable to ReDoS",
"AKA": "",
"STATE": "PUBLIC"
},
"source": {
"defect": [
"GHSL-2021-108"
],
"advisory": "GHSL-2021-108",
"discovery": "UNKNOWN"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "python-mechanize",
"product": {
"product_data": [
{
"product_name": "mechanize",
"version": {
"version_data": [
{
"version_name": "0.4.6",
"version_affected": "<",
"version_value": "0.4.6",
"platform": ""
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"generator": {
"engine": "Vulnogram 0.0.9"
},
"CVE_data_meta": {
"ID": "CVE-2021-32837",
"ASSIGNER": "security-advisories@github.com",
"DATE_PUBLIC": "",
"TITLE": "mechanize vulnerable to ReDoS",
"AKA": "",
"STATE": "PUBLIC"
},
"source": {
"defect": [
"GHSL-2021-108"
],
"advisory": "GHSL-2021-108",
"discovery": "UNKNOWN"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "python-mechanize",
"product": {
"product_data": [
{
"product_name": "mechanize",
"version": {
"version_data": [
{
"version_name": "0.4.6",
"version_affected": "<",
"version_value": "0.4.6",
"platform": ""
}
]
}
}
]
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-1333 Inefficient Regular Expression Complexity"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-1333 Inefficient Regular Expression Complexity"
}
]
}
]
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "mechanize, a library for automatically interacting with HTTP web servers, contains a regular expression that is vulnerable to regular expression denial of service (ReDoS) prior to version 0.4.6. If a web server responds in a malicious way, then mechanize could crash. Version 0.4.6 has a patch for the issue."
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"url": "https://securitylab.github.com/advisories/GHSL-2021-108-python-mechanize-mechanize/",
"name": "https://securitylab.github.com/advisories/GHSL-2021-108-python-mechanize-mechanize/"
},
{
"refsource": "MISC",
"url": "https://github.com/python-mechanize/mechanize/blob/3acb1836f3fd8edc5a758a417dd46b53832ae3b5/mechanize/_urllib2_fork.py#L878-L879",
"name": "https://github.com/python-mechanize/mechanize/blob/3acb1836f3fd8edc5a758a417dd46b53832ae3b5/mechanize/_urllib2_fork.py#L878-L879"
},
{
"refsource": "MISC",
"url": "https://github.com/python-mechanize/mechanize/releases/tag/v0.4.6",
"name": "https://github.com/python-mechanize/mechanize/releases/tag/v0.4.6"
},
{
"refsource": "MISC",
"url": "https://github.com/python-mechanize/mechanize/commit/dd05334448e9f39814bab044d2eaa5ef69b410d6",
"name": "https://github.com/python-mechanize/mechanize/commit/dd05334448e9f39814bab044d2eaa5ef69b410d6"
}
]
},
"configuration": [],
"impact": {
"cvss": {
"version": "3.1",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"baseScore": 7.5,
"baseSeverity": "HIGH"
}
},
"exploit": [],
"work_around": [],
"solution": [],
"credit": []
}
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "mechanize, a library for automatically interacting with HTTP web servers, contains a regular expression that is vulnerable to regular expression denial of service (ReDoS) prior to version 0.4.6. If a web server responds in a malicious way, then mechanize could crash. Version 0.4.6 has a patch for the issue."
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"url": "https://securitylab.github.com/advisories/GHSL-2021-108-python-mechanize-mechanize/",
"name": "https://securitylab.github.com/advisories/GHSL-2021-108-python-mechanize-mechanize/"
},
{
"refsource": "MISC",
"url": "https://github.com/python-mechanize/mechanize/blob/3acb1836f3fd8edc5a758a417dd46b53832ae3b5/mechanize/_urllib2_fork.py#L878-L879",
"name": "https://github.com/python-mechanize/mechanize/blob/3acb1836f3fd8edc5a758a417dd46b53832ae3b5/mechanize/_urllib2_fork.py#L878-L879"
},
{
"refsource": "MISC",
"url": "https://github.com/python-mechanize/mechanize/releases/tag/v0.4.6",
"name": "https://github.com/python-mechanize/mechanize/releases/tag/v0.4.6"
},
{
"refsource": "MISC",
"url": "https://github.com/python-mechanize/mechanize/commit/dd05334448e9f39814bab044d2eaa5ef69b410d6",
"name": "https://github.com/python-mechanize/mechanize/commit/dd05334448e9f39814bab044d2eaa5ef69b410d6"
},
{
"refsource": "MLIST",
"name": "[debian-lts-announce] 20230620 [SECURITY] [DLA 3460-1] python-mechanize security update",
"url": "https://lists.debian.org/debian-lts-announce/2023/06/msg00022.html"
}
]
},
"configuration": [],
"impact": {
"cvss": {
"version": "3.1",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"baseScore": 7.5,
"baseSeverity": "HIGH"
}
},
"exploit": [],
"work_around": [],
"solution": [],
"credit": []
}

View File

@ -1,18 +1,70 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-2400",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "security@devolutions.net",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Improper deletion of resource in the user management feature in Devolutions Server 2023.1.8 and earlier allows an administrator to view users vaults of deleted users via database access.\n\n"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Devolutions",
"product": {
"product_data": [
{
"product_name": "Server",
"version": {
"version_data": [
{
"version_affected": "<=",
"version_name": "0",
"version_value": "2023.1.8"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://devolutions.net/security/advisories/DEVO-2023-0014",
"refsource": "MISC",
"name": "https://devolutions.net/security/advisories/DEVO-2023-0014"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
}
}

View File

@ -0,0 +1,18 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-3341",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
}
]
}
}