"-Synchronized-Data."

This commit is contained in:
CVE Team 2020-03-19 17:01:14 +00:00
parent eaec28d071
commit 0a3cef0730
No known key found for this signature in database
GPG Key ID: 5708902F06FEF743
3 changed files with 122 additions and 6 deletions

View File

@ -1,17 +1,61 @@
{ {
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": { "CVE_data_meta": {
"ID": "CVE-2019-11361",
"ASSIGNER": "cve@mitre.org", "ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED" "ID": "CVE-2019-11361",
"STATE": "PUBLIC"
}, },
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": { "description": {
"description_data": [ "description_data": [
{ {
"lang": "eng", "lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided." "value": "Zoho ManageEngine Remote Access Plus 10.0.258 does not validate user permissions properly, allowing for privilege escalation and eventually a full application takeover."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"name": "https://www.manageengine.com/remote-desktop-management/knowledge-base/elevation-of-privilege.html",
"url": "https://www.manageengine.com/remote-desktop-management/knowledge-base/elevation-of-privilege.html"
} }
] ]
} }

View File

@ -96,6 +96,11 @@
"refsource": "CONFIRM", "refsource": "CONFIRM",
"name": "https://www.synology.com/security/advisory/Synology_SA_20_03", "name": "https://www.synology.com/security/advisory/Synology_SA_20_03",
"url": "https://www.synology.com/security/advisory/Synology_SA_20_03" "url": "https://www.synology.com/security/advisory/Synology_SA_20_03"
},
{
"refsource": "MISC",
"name": "http://packetstormsecurity.com/files/156809/Broadcom-Wi-Fi-KR00K-Proof-Of-Concept.html",
"url": "http://packetstormsecurity.com/files/156809/Broadcom-Wi-Fi-KR00K-Proof-Of-Concept.html"
} }
] ]
} }

View File

@ -0,0 +1,67 @@
{
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-16382",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in Ivanti Workspace Control 10.3.110.0. One is able to bypass Ivanti's FileGuard folder protection by renaming the WMTemp work folder used by PowerGrid. A malicious PowerGrid XML file can then be created, after which the folder is renamed back to its original value. Also, CVE-2018-15591 exploitation can consequently be achieved by using PowerGrid with the /SEE parameter to execute the arbitrary command specified in the XML file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"url": "https://twitter.com/jmoosdijk",
"refsource": "MISC",
"name": "https://twitter.com/jmoosdijk"
},
{
"refsource": "CONFIRM",
"name": "https://forums.ivanti.com/s/article/Security-Alert-Ivanti-Workspace-Control-September-2019",
"url": "https://forums.ivanti.com/s/article/Security-Alert-Ivanti-Workspace-Control-September-2019"
}
]
}
}