"-Synchronized-Data."

This commit is contained in:
CVE Team 2022-11-25 00:00:35 +00:00
parent 29cb22a8e6
commit 0c18fa3bde
No known key found for this signature in database
GPG Key ID: E3252B3D49582C98
10 changed files with 801 additions and 40 deletions

View File

@ -1,17 +1,103 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2022-25164",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 all versions and Mitsubishi Electric MX OPC UA Module Configurator-R all versions allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthorized users can gain unauthorized access to the CPU module and the OPC UA server module."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-312 Cleartext Storage of Sensitive Information",
"cweId": "CWE-312"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Mitsubishi Electric Corporation",
"product": {
"product_data": [
{
"product_name": "GX Works3",
"version": {
"version_data": [
{
"version_value": "all versions",
"version_affected": "="
}
]
}
},
{
"product_name": "MX OPC UA Module Configurator-R",
"version": {
"version_data": [
{
"version_value": "all versions",
"version_affected": "="
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf",
"refsource": "MISC",
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
},
{
"url": "https://jvn.jp/vu/JVNVU97244961/index.html",
"refsource": "MISC",
"name": "https://jvn.jp/vu/JVNVU97244961/index.html"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,92 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2022-29825",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 all versions allows an unauthenticated attacker to disclose sensitive information. As a result, unauthorized users may view or execute programs illegally."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-259 Use of Hard-coded Password",
"cweId": "CWE-259"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Mitsubishi Electric Corporation",
"product": {
"product_data": [
{
"product_name": "GX Works3",
"version": {
"version_data": [
{
"version_value": "all versions",
"version_affected": "="
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf",
"refsource": "MISC",
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
},
{
"url": "https://jvn.jp/vu/JVNVU97244961/index.html",
"refsource": "MISC",
"name": "https://jvn.jp/vu/JVNVU97244961/index.html"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,92 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2022-29826",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions 1.086Q and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthorized users may view or execute programs illegally."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-312 Cleartext Storage of Sensitive Information",
"cweId": "CWE-312"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Mitsubishi Electric Corporation",
"product": {
"product_data": [
{
"product_name": "GX Works3",
"version": {
"version_data": [
{
"version_value": "1.086Q and prior",
"version_affected": "="
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf",
"refsource": "MISC",
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
},
{
"url": "https://jvn.jp/vu/JVNVU97244961/index.html",
"refsource": "MISC",
"name": "https://jvn.jp/vu/JVNVU97244961/index.html"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,92 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2022-29827",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 all versions allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthorized users may view or execute programs illegally."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-321 Use of Hard-coded Cryptographic Key",
"cweId": "CWE-321"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Mitsubishi Electric Corporation",
"product": {
"product_data": [
{
"product_name": "GX Works3",
"version": {
"version_data": [
{
"version_value": "all versions",
"version_affected": "="
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf",
"refsource": "MISC",
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
},
{
"url": "https://jvn.jp/vu/JVNVU97244961/index.html",
"refsource": "MISC",
"name": "https://jvn.jp/vu/JVNVU97244961/index.html"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,92 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2022-29828",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 all versions allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthorized users may view or execute programs illegally."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-321 Use of Hard-coded Cryptographic Key",
"cweId": "CWE-321"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Mitsubishi Electric Corporation",
"product": {
"product_data": [
{
"product_name": "GX Works3",
"version": {
"version_data": [
{
"version_value": "all versions",
"version_affected": "="
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf",
"refsource": "MISC",
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
},
{
"url": "https://jvn.jp/vu/JVNVU97244961/index.html",
"refsource": "MISC",
"name": "https://jvn.jp/vu/JVNVU97244961/index.html"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,92 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2022-29829",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 all versions allows a remote unauthenticated attacker to disclose sensitive information . As a result, unauthorized users may view or execute programs illegally."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-321 Use of Hard-coded Cryptographic Key",
"cweId": "CWE-321"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Mitsubishi Electric Corporation",
"product": {
"product_data": [
{
"product_name": "GX Works3",
"version": {
"version_data": [
{
"version_value": "all versions",
"version_affected": "="
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf",
"refsource": "MISC",
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
},
{
"url": "https://jvn.jp/vu/JVNVU97244961/index.html",
"refsource": "MISC",
"name": "https://jvn.jp/vu/JVNVU97244961/index.html"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,92 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2022-29830",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 all versions allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthorized users may obtain information about project files illegally."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-321 Use of Hard-coded Cryptographic Key",
"cweId": "CWE-321"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Mitsubishi Electric Corporation",
"product": {
"product_data": [
{
"product_name": "GX Works3",
"version": {
"version_data": [
{
"version_value": "all versions",
"version_affected": "="
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf",
"refsource": "MISC",
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
},
{
"url": "https://jvn.jp/vu/JVNVU97244961/index.html",
"refsource": "MISC",
"name": "https://jvn.jp/vu/JVNVU97244961/index.html"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,92 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2022-29831",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later allows a remote unauthorized attacker to obtain information about the project file for MELSEC safety CPU modules."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-259 Use of Hard-coded Password",
"cweId": "CWE-259"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Mitsubishi Electric Corporation",
"product": {
"product_data": [
{
"product_name": "GX Works3",
"version": {
"version_data": [
{
"version_value": "1.015R and later",
"version_affected": "="
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf",
"refsource": "MISC",
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
},
{
"url": "https://jvn.jp/vu/JVNVU97244961",
"refsource": "MISC",
"name": "https://jvn.jp/vu/JVNVU97244961"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,92 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2022-29832",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Cleartext Storage of Sensitive Information in Memory vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later allows a remote unauthorized attacker to disclose sensitive information. As a result, unauthorized users could obtain information about the project file for MELSEC safety CPU modules."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-316 Cleartext Storage of Sensitive Information in Memory",
"cweId": "CWE-316"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Mitsubishi Electric Corporation",
"product": {
"product_data": [
{
"product_name": "GX Works3",
"version": {
"version_data": [
{
"version_value": "1.015R and later",
"version_affected": "="
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf",
"refsource": "MISC",
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
},
{
"url": "https://jvn.jp/vu/JVNVU97244961",
"refsource": "MISC",
"name": "https://jvn.jp/vu/JVNVU97244961"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,92 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2022-29833",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Insufficiently Protected Credentials vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later allows a remote unauthorized attacker to disclose sensitive information. As a result, unauthorized users could access to MELSEC safety CPU modules illgally."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-522 Insufficiently Protected Credentials",
"cweId": "CWE-522"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Mitsubishi Electric Corporation",
"product": {
"product_data": [
{
"product_name": "GX Works3",
"version": {
"version_data": [
{
"version_value": "1.015R and later",
"version_affected": "="
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf",
"refsource": "MISC",
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
},
{
"url": "https://jvn.jp/vu/JVNVU97244961",
"refsource": "MISC",
"name": "https://jvn.jp/vu/JVNVU97244961"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:N/I:H/A:N",
"version": "3.1"
}
]
}