"-Synchronized-Data."

This commit is contained in:
CVE Team 2020-12-29 16:01:43 +00:00
parent eae6b6abc2
commit 0f6df39f64
No known key found for this signature in database
GPG Key ID: 5708902F06FEF743
4 changed files with 188 additions and 12 deletions

View File

@ -4,14 +4,58 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-5801",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "vulnreport@tenable.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "Rockwell FactoryTalk Linx",
"version": {
"version_data": [
{
"version_value": "All versions of FactoryTalk Linx"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Unauthenticated Remote DoS"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"name": "https://www.tenable.com/security/research/tra-2020-71",
"url": "https://www.tenable.com/security/research/tra-2020-71"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected."
}
]
}

View File

@ -4,14 +4,58 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-5802",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "vulnreport@tenable.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "Rockwell FactoryTalk Linx",
"version": {
"version_data": [
{
"version_value": "All versions of FactoryTalk Linx"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Unauthenticated Remote Denial of Service"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"name": "https://www.tenable.com/security/research/tra-2020-71",
"url": "https://www.tenable.com/security/research/tra-2020-71"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted ConfigureItems message to TCP port 4241. This will cause an unhandled exception, resulting in termination of RSLinxNG.exe. Observed in FactoryTalk 6.11. All versions of FactoryTalk Linx are affected."
}
]
}

View File

@ -4,14 +4,58 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-5806",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "vulnreport@tenable.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "Rockwell FactoryTalk Linx",
"version": {
"version_data": [
{
"version_value": "All versions of FactoryTalk Linx"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Local Denial of Service"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"name": "https://www.tenable.com/security/research/tra-2020-71",
"url": "https://www.tenable.com/security/research/tra-2020-71"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll. This can be done by sending a specially crafted message to 127.0.0.1:7153. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected."
}
]
}

View File

@ -4,14 +4,58 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-5807",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "vulnreport@tenable.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "Rockwell FactoryTalk Diagnostics",
"version": {
"version_data": [
{
"version_value": "All versions of FactoryTalk Diagnostics"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Unauthenticated Remote Denial of Service"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"name": "https://www.tenable.com/security/research/tra-2020-71",
"url": "https://www.tenable.com/security/research/tra-2020-71"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpy_s() if a local user opens FactoryTalk Diagnostics Viewer (FTDiagViewer.exe) to view the log entry. Observed in FactoryTalk Diagnostics 6.11. All versions of FactoryTalk Diagnostics are affected."
}
]
}