"-Synchronized-Data."

This commit is contained in:
CVE Team 2023-09-25 00:00:35 +00:00
parent ce9022af9b
commit 100328e3c1
No known key found for this signature in database
GPG Key ID: E3252B3D49582C98
3 changed files with 228 additions and 8 deletions

View File

@ -0,0 +1,18 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-43825",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
}
]
}
}

View File

@ -1,17 +1,110 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-5145",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "cna@vuldb.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "** UNSUPPPORTED WHEN ASSIGNED ** ** UNSUPPORTED WHEN ASSIGNED ** A vulnerability has been found in D-Link DAR-7000 up to 20151231 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /sysmanage/licence.php. The manipulation of the argument file_upload leads to unrestricted upload. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-240241 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced."
},
{
"lang": "deu",
"value": "** UNSUPPPORTED WHEN ASSIGNED ** In D-Link DAR-7000 bis 20151231 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Das betrifft eine unbekannte Funktionalit\u00e4t der Datei /sysmanage/licence.php. Dank Manipulation des Arguments file_upload mit unbekannten Daten kann eine unrestricted upload-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-434 Unrestricted Upload",
"cweId": "CWE-434"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "D-Link",
"product": {
"product_data": [
{
"product_name": "DAR-7000",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "20151231"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://vuldb.com/?id.240241",
"refsource": "MISC",
"name": "https://vuldb.com/?id.240241"
},
{
"url": "https://vuldb.com/?ctiid.240241",
"refsource": "MISC",
"name": "https://vuldb.com/?ctiid.240241"
},
{
"url": "https://github.com/llixixi/cve/blob/main/D-LINK-DAR-7000_upload_%20licence.md",
"refsource": "MISC",
"name": "https://github.com/llixixi/cve/blob/main/D-LINK-DAR-7000_upload_%20licence.md"
},
{
"url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10354",
"refsource": "MISC",
"name": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10354"
}
]
},
"credits": [
{
"lang": "en",
"value": "llixixioo (VulDB User)"
}
],
"impact": {
"cvss": [
{
"version": "3.1",
"baseScore": 6.3,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"baseSeverity": "MEDIUM"
},
{
"version": "3.0",
"baseScore": 6.3,
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"baseSeverity": "MEDIUM"
},
{
"version": "2.0",
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"baseSeverity": "MEDIUM"
}
]
}

View File

@ -1,17 +1,126 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-5146",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "cna@vuldb.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "** UNSUPPPORTED WHEN ASSIGNED ** ** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000 and DAR-8000 up to 20151231 and classified as critical. Affected by this issue is some unknown functionality of the file /sysmanage/updatelib.php. The manipulation of the argument file_upload leads to unrestricted upload. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-240242 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced."
},
{
"lang": "deu",
"value": "** UNSUPPPORTED WHEN ASSIGNED ** Eine Schwachstelle wurde in D-Link DAR-7000 and DAR-8000 bis 20151231 gefunden. Sie wurde als kritisch eingestuft. Dies betrifft einen unbekannten Teil der Datei /sysmanage/updatelib.php. Mit der Manipulation des Arguments file_upload mit unbekannten Daten kann eine unrestricted upload-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-434 Unrestricted Upload",
"cweId": "CWE-434"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "D-Link",
"product": {
"product_data": [
{
"product_name": "DAR-7000",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "20151231"
}
]
}
},
{
"product_name": "DAR-8000",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "20151231"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://vuldb.com/?id.240242",
"refsource": "MISC",
"name": "https://vuldb.com/?id.240242"
},
{
"url": "https://vuldb.com/?ctiid.240242",
"refsource": "MISC",
"name": "https://vuldb.com/?ctiid.240242"
},
{
"url": "https://github.com/llixixi/cve/blob/main/D-LINK-DAR-7000_upload_%20updatelib.md",
"refsource": "MISC",
"name": "https://github.com/llixixi/cve/blob/main/D-LINK-DAR-7000_upload_%20updatelib.md"
},
{
"url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10354",
"refsource": "MISC",
"name": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10354"
},
{
"url": "https://github.com/llixixi/cve/blob/main/D-LINK-DAR-8000-10_upload_%20updatelib.md",
"refsource": "MISC",
"name": "https://github.com/llixixi/cve/blob/main/D-LINK-DAR-8000-10_upload_%20updatelib.md"
}
]
},
"credits": [
{
"lang": "en",
"value": "llixixioo (VulDB User)"
}
],
"impact": {
"cvss": [
{
"version": "3.1",
"baseScore": 6.3,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"baseSeverity": "MEDIUM"
},
{
"version": "3.0",
"baseScore": 6.3,
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"baseSeverity": "MEDIUM"
},
{
"version": "2.0",
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"baseSeverity": "MEDIUM"
}
]
}