"Update to multiple CVEs"

This commit is contained in:
Esmeralda Paz 2022-03-28 09:15:00 -07:00
parent 6d50b2853e
commit 13f106d383
5 changed files with 380 additions and 27 deletions

View File

@ -1,8 +1,33 @@
{
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ASSIGNER": "cybersecurity@se.com",
"ID": "CVE-2019-6834",
"STATE": "RESERVED"
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Software Update (SESU) SUT Service component",
"version": {
"version_data": [
{
"version_affected": "<=",
"version_name": "V2.1.1",
"version_value": "V2.3.0"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
@ -11,8 +36,50 @@
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A CWE-502: Deserialization of Untrusted Data vulnerability exists which could allow an attacker to execute arbitrary code on the targeted system with SYSTEM privileges when placing a malicious user to be authenticated for this vulnerability to be successfully exploited. Affected Product: Schneider Electric Software Update (SESU) SUT Service component (V2.1.1 to V2.3.0)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-502 Deserialization of Untrusted Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-225-06/"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}

View File

@ -1,18 +1,84 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@se.com",
"ID": "CVE-2021-22794",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "StruxureWare Data Center Expert",
"version": {
"version_data": [
{
"version_affected": "<",
"version_value": "V7.8.1"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03/"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}

View File

@ -1,18 +1,84 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@se.com",
"ID": "CVE-2021-22795",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "StruxureWare Data Center Expert",
"version": {
"version_data": [
{
"version_affected": "<",
"version_value": "V7.8.1"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-78 OS Command Injection"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-03/"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}

View File

@ -1,18 +1,105 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@se.com",
"ID": "CVE-2021-22797",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EcoStruxure Control Expert",
"version": {
"version_data": [
{
"version_affected": "<",
"version_value": "V15.0 SP1"
}
]
}
},
{
"product_name": "EcoStruxure Process Expert",
"version": {
"version_data": [
{
"version_affected": "<",
"version_value": "2020"
}
]
}
},
{
"product_name": "SCADAPack RemoteConnect for x70",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions) "
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-257-01/"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}

View File

@ -1,18 +1,85 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@se.com",
"ID": "CVE-2022-0221",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SCADAPack Workbench",
"version": {
"version_data": [
{
"version_affected": "<",
"version_name": "6.6.8a",
"version_value": "and prior"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could result in information disclosure when opening a malicious solution file provided by an attacker with SCADAPack Workbench. This could be exploited to pass data from local files to a remote system controlled by an attacker. Affected Product: SCADAPack Workbench (6.6.8a and prior) "
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-611 Improper Restriction of XML External Entity Reference ('XXE')"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"url": "https://www.se.com/ww/en/download/document/SEVD-2022-087-01/"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}