@ -149,7 +149,7 @@
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions"
|
||||
"version_value": "All versions < V4.0.1"
|
||||
}
|
||||
]
|
||||
}
|
||||
@ -656,7 +656,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC Compact Field Unit, SIMATIC ET200AL, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200ecoPN (except 6ES7141-6BG00-0BB0, 6ES7141-6BH00-0BB0, 6ES7142-6BG00-0BB0, 6ES7142-6BR00-0BB0, 6S7143-6BH00-0BB0, 6ES7146-6FF00-0AB0, 6ES7148-6JD00-0AB0 and 6ES7148-6JG00-0BB0), SIMATIC ET200pro, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-200 Smart, SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-400 H V6 CPU family and below (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 CPU family and below (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SIMOCODE pro V EIP (incl. SIPLUS variants), SIMOCODE pro V PN (incl. SIPLUS variants), SIMOTION C, SIMOTION D (incl. SIPLUS variants), SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants), SIMOTION P V4.4 and V4.5, SIMOTION P V5, SINAMICS DCM w. PN, SINAMICS DCP w. PN, SINAMICS G110M w. PN, SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants), SINAMICS G130 V4.7 w. PN, SINAMICS G130 V4.8 w. PN, SINAMICS G150 V4.7 w. PN, SINAMICS G150 V4.8 w. PN, SINAMICS GH150 V4.7 w. PROFINET, SINAMICS GL150 V4.7 w. PROFINET, SINAMICS GM150 V4.7 w. PROFINET, SINAMICS S110 w. PN, SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants), SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants), SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants), SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants), SINAMICS S150 V4.7 w. PN, SINAMICS S150 V4.8 w. PN, SINAMICS SL150 V4.7.0 w. PROFINET, SINAMICS SL150 V4.7.4 w. PROFINET, SINAMICS SL150 V4.7.5 w. PROFINET, SINAMICS SM120 V4.7 w. PROFINET, SINAMICS V90 w. PN, SINUMERIK 840D sl, SIRIUS Soft Starter 3RW44 PN. Specially crafted packets sent to port 161/udp could cause a Denial-of-Service condition. The affected devices must be restarted manually."
|
||||
"value": "A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC Compact Field Unit, SIMATIC ET200AL, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200ecoPN (except 6ES7141-6BG00-0BB0, 6ES7141-6BH00-0BB0, 6ES7142-6BG00-0BB0, 6ES7142-6BR00-0BB0, 6S7143-6BH00-0BB0, 6ES7146-6FF00-0AB0, 6ES7148-6JD00-0AB0 and 6ES7148-6JG00-0BB0), SIMATIC ET200pro, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-200 Smart, SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-400 H V6 CPU family and below (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 CPU family and below (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SIMOCODE pro V EIP (incl. SIPLUS variants), SIMOCODE pro V PN (incl. SIPLUS variants), SIMOTION C, SIMOTION D (incl. SIPLUS variants), SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants), SIMOTION P V4.4 and V4.5, SIMOTION P V5, SINAMICS DCM w. PN, SINAMICS DCP w. PN, SINAMICS G110M w. PN, SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants), SINAMICS G130 V4.7 w. PN, SINAMICS G130 V4.8 w. PN, SINAMICS G150 V4.7 w. PN, SINAMICS G150 V4.8 w. PN, SINAMICS GH150 V4.7 w. PROFINET, SINAMICS GL150 V4.7 w. PROFINET, SINAMICS GM150 V4.7 w. PROFINET, SINAMICS S110 w. PN, SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants), SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants), SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants), SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants), SINAMICS S150 V4.7 w. PN, SINAMICS S150 V4.8 w. PN, SINAMICS SL150 V4.7.0 w. PROFINET, SINAMICS SL150 V4.7.4 w. PROFINET, SINAMICS SL150 V4.7.5 w. PROFINET, SINAMICS SM120 V4.7 w. PROFINET, SINAMICS V90 w. PN, SINUMERIK 840D sl, SIRIUS Soft Starter 3RW44 PN. Specially crafted packets sent to port 161/udp could cause a Denial-of-Service condition. The affected devices must be restarted manually.\n"
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -175,7 +175,7 @@
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SCALANCE XM400",
|
||||
"product_name": "SCALANCE XM-400 Family",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
@ -185,7 +185,7 @@
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SCALANCE XR500",
|
||||
"product_name": "SCALANCE XR-500 Family",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
@ -324,6 +324,16 @@
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants)",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions < V4.0.1"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants)",
|
||||
"version": {
|
||||
@ -369,7 +379,7 @@
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All Versions < V7.0.6"
|
||||
"version_value": "All Versions < V7.0.6"
|
||||
}
|
||||
]
|
||||
}
|
||||
@ -485,7 +495,7 @@
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC NET CP 343-1 Adv (incl. SIPLUS variants)",
|
||||
"product_name": "SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants)",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
@ -505,7 +515,7 @@
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC NET CP 343-1 Std (incl. SIPLUS variants)",
|
||||
"product_name": "SIMATIC NET CP 343-1 Standard (incl. SIPLUS variants)",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
@ -515,7 +525,7 @@
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC NET CP 443-1 Adv (incl. SIPLUS variants)",
|
||||
"product_name": "SIMATIC NET CP 443-1 Advanced (incl. SIPLUS variants)",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
@ -535,7 +545,7 @@
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC NET CP 443-1 Std (incl. SIPLUS variants)",
|
||||
"product_name": "SIMATIC NET CP 443-1 Standard (incl. SIPLUS variants)",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
@ -779,7 +789,7 @@
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions < V1.2 HF 1"
|
||||
"version_value": "All versions < V1.2 HF1"
|
||||
}
|
||||
]
|
||||
}
|
||||
@ -1116,7 +1126,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Specially crafted PROFINET DCP broadcast packets could cause a Denial-of-Service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected."
|
||||
"value": "Specially crafted PROFINET DCP broadcast packets could cause a Denial-of-Service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.\n"
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -135,7 +135,7 @@
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SCALANCE XM400",
|
||||
"product_name": "SCALANCE XM-400 Family",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
@ -145,7 +145,7 @@
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SCALANCE XR500",
|
||||
"product_name": "SCALANCE XR-500 Family",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
@ -244,6 +244,16 @@
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants)",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions < V4.0.1"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants)",
|
||||
"version": {
|
||||
@ -289,7 +299,7 @@
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All Versions < V7.0.6"
|
||||
"version_value": "All Versions < V7.0.6"
|
||||
}
|
||||
]
|
||||
}
|
||||
@ -405,7 +415,7 @@
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC NET CP 343-1 Adv (incl. SIPLUS variants)",
|
||||
"product_name": "SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants)",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
@ -425,7 +435,7 @@
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC NET CP 343-1 Std (incl. SIPLUS variants)",
|
||||
"product_name": "SIMATIC NET CP 343-1 Standard (incl. SIPLUS variants)",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
@ -435,7 +445,7 @@
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC NET CP 443-1 Adv (incl. SIPLUS variants)",
|
||||
"product_name": "SIMATIC NET CP 443-1 Advanced (incl. SIPLUS variants)",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
@ -455,7 +465,7 @@
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC NET CP 443-1 Std (incl. SIPLUS variants)",
|
||||
"product_name": "SIMATIC NET CP 443-1 Standard (incl. SIPLUS variants)",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
@ -689,7 +699,7 @@
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions < V1.2 HF 1"
|
||||
"version_value": "All versions < V1.2 HF1"
|
||||
}
|
||||
]
|
||||
}
|
||||
@ -956,7 +966,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a Denial-of-Service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices."
|
||||
"value": "Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a Denial-of-Service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices.\n"
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -159,7 +159,7 @@
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions"
|
||||
"version_value": "All versions < V4.0.1"
|
||||
}
|
||||
]
|
||||
}
|
||||
@ -556,7 +556,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC CFU PA, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET200AL, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC ET200ecoPN (except 6ES7141-6BG00-0BB0, 6ES7141-6BH00-0BB0, 6ES7142-6BG00-0BB0, 6ES7142-6BR00-0BB0, 6S7143-6BH00-0BB0, 6ES7146-6FF00-0AB0, 6ES7148-6JD00-0AB0 and 6ES7148-6JG00-0BB0), SIMATIC ET200pro, SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (incl. SIPLUS variants), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants), SIMATIC HMI KTP Mobile Panels, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC PROFINET Driver, SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 PN Control Unit, SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl. Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of specially crafted UDP packets are sent to device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
|
||||
"value": "A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC CFU PA, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET200AL, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC ET200ecoPN (except 6ES7141-6BG00-0BB0, 6ES7141-6BH00-0BB0, 6ES7142-6BG00-0BB0, 6ES7142-6BR00-0BB0, 6S7143-6BH00-0BB0, 6ES7146-6FF00-0AB0, 6ES7148-6JD00-0AB0 and 6ES7148-6JG00-0BB0), SIMATIC ET200pro, SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (incl. SIPLUS variants), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants), SIMATIC HMI KTP Mobile Panels, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC PROFINET Driver, SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 PN Control Unit, SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl. Affected devices contain a vulnerability that allows an unauthenticated attacker\nto trigger a denial-of-service condition. The vulnerability can be triggered\nif a large amount of specially crafted UDP packets are sent to device.\n\nThe security vulnerability could be exploited by an attacker with network\naccess to the affected systems. Successful exploitation requires no system\nprivileges and no user interaction. An attacker could use the vulnerability\nto compromise availability of the device.\n\nAt the time of advisory publication no public exploitation of this security\nvulnerability was known.\n"
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -19,7 +19,7 @@
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions >= V14"
|
||||
"version_value": "All versions < V16"
|
||||
}
|
||||
]
|
||||
}
|
||||
@ -29,7 +29,7 @@
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions"
|
||||
"version_value": "All versions <= V16"
|
||||
}
|
||||
]
|
||||
}
|
||||
@ -39,7 +39,7 @@
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions"
|
||||
"version_value": "All versions <= V16"
|
||||
}
|
||||
]
|
||||
}
|
||||
@ -49,7 +49,7 @@
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions"
|
||||
"version_value": "All versions <= V16"
|
||||
}
|
||||
]
|
||||
}
|
||||
@ -76,7 +76,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions >= V14), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI Mobile Panels (All versions), SIMATIC HMI Unified Comfort Panels (All versions). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack."
|
||||
"value": "A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Panels (All versions <= V16), SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently block excessive authentication attempts.\n\nThis could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.\n"
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -19,7 +19,7 @@
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions"
|
||||
"version_value": "All versions <= V16"
|
||||
}
|
||||
]
|
||||
}
|
||||
@ -46,7 +46,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack."
|
||||
"value": "A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string.\n\nThis could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.\n"
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -29,7 +29,7 @@
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "SE2020MP13"
|
||||
"version_value": "All versions < SE2020MP14"
|
||||
}
|
||||
]
|
||||
}
|
||||
@ -66,7 +66,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)"
|
||||
"value": "A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)"
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -19,7 +19,17 @@
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions"
|
||||
"version_value": "All versions < V4 SP2"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC NET PC Software V16",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions < V16 Upd3"
|
||||
}
|
||||
]
|
||||
}
|
||||
@ -229,7 +239,7 @@
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions"
|
||||
"version_value": "All versions < V1.0 SP2"
|
||||
}
|
||||
]
|
||||
}
|
||||
@ -286,7 +296,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions), SIMATIC NET PC software (All versions V16 < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (All versions < V5.6 SP2 HF3), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC WinCC OA V3.16 (All versions < P018), SIMATIC WinCC OA V3.17 (All versions < P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions), SINEMA Server (All versions), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A component within the affected application regularly calls a helper binary with SYSTEM privileges while the call path is not quoted."
|
||||
"value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC NET PC software (All versions V16 < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (All versions < V5.6 SP2 HF3), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC WinCC OA V3.16 (All versions < P018), SIMATIC WinCC OA V3.17 (All versions < P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A component within the affected application regularly calls a helper binary with SYSTEM privileges while the call path is not quoted.\n"
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -29,7 +29,7 @@
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "SE2020MP13"
|
||||
"version_value": "All versions < SE2020MP14"
|
||||
}
|
||||
]
|
||||
}
|
||||
@ -66,7 +66,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12529)"
|
||||
"value": "A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12529)\n"
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -56,7 +56,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)"
|
||||
"value": "A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)\n"
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -29,7 +29,7 @@
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "SE2020MP13"
|
||||
"version_value": "All versions < SE2020MP14"
|
||||
}
|
||||
]
|
||||
}
|
||||
@ -66,7 +66,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13040)"
|
||||
"value": "A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13040)\n"
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -1,17 +1,70 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "productcert@siemens.com",
|
||||
"ID": "CVE-2021-27387",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2021-27387",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"data_type": "CVE",
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"vendor_name": "Siemens",
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "Simcenter Femap 2020.2",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions < V2020.2.MP3"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "Simcenter Femap 2021.1",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions < V2021.1.MP3"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-787: Out-of-bounds Write"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "A vulnerability has been identified in Simcenter Femap 2020.2 (All versions < V2020.2.MP3), Simcenter Femap 2021.1 (All versions < V2021.1.MP3). The femap.exe application lacks proper validation of user-supplied data when parsing FEMAP files. This could result in an out of bounds write past the end of an allocated structure, a different vulnerability than CVE-2021-27399.\n\nAn attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12819)\n"
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-133038.pdf"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,70 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "productcert@siemens.com",
|
||||
"ID": "CVE-2021-27390",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2021-27390",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"data_type": "CVE",
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"vendor_name": "Siemens",
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "JT2Go",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions < V13.1.0.3"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "Teamcenter Visualization",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions < V13.1.0.3"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-787: Out-of-bounds Write"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "A vulnerability has been identified in JT2Go (All versions < V13.1.0.3), Teamcenter Visualization (All versions < V13.1.0.3). The TIFF_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the end of an allocated structure.\n\nAn attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13131)\n"
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-645530.pdf"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,70 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "productcert@siemens.com",
|
||||
"ID": "CVE-2021-27399",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2021-27399",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"data_type": "CVE",
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"vendor_name": "Siemens",
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "Simcenter Femap 2020.2",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions < V2020.2.MP3"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "Simcenter Femap 2021.1",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions < V2021.1.MP3"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-787: Out-of-bounds Write"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "A vulnerability has been identified in Simcenter Femap 2020.2 (All versions < V2020.2.MP3), Simcenter Femap 2021.1 (All versions < V2021.1.MP3). The femap.exe application lacks proper validation of user-supplied data when parsing FEMAP files. This could result in an out of bounds write past the end of an allocated structure, a different vulnerability than CVE-2021-27387.\n\nAn attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12820)\n"
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-133038.pdf"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,150 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "productcert@siemens.com",
|
||||
"ID": "CVE-2021-31340",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2021-31340",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"data_type": "CVE",
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"vendor_name": "Siemens",
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "SIMATIC RF166C",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions > V1.1 and < V1.3.2"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC RF185C",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions > V1.1 and < V1.3.2"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC RF186C",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions > V1.1 and < V1.3.2"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC RF186CI",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions > V1.1 and < V1.3.2"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC RF188C",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions > V1.1 and < V1.3.2"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC RF188CI",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions > V1.1 and < V1.3.2"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC RF360R",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC RF615R",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions > V3.0"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC RF680R",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions > V3.0"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC RF685R",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions > V3.0"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-400: Uncontrolled Resource Consumption"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "A vulnerability has been identified in SIMATIC RF166C (All versions > V1.1 and < V1.3.2), SIMATIC RF185C (All versions > V1.1 and < V1.3.2), SIMATIC RF186C (All versions > V1.1 and < V1.3.2), SIMATIC RF186CI (All versions > V1.1 and < V1.3.2), SIMATIC RF188C (All versions > V1.1 and < V1.3.2), SIMATIC RF188CI (All versions > V1.1 and < V1.3.2), SIMATIC RF360R (All versions), SIMATIC RF615R (All versions > V3.0), SIMATIC RF680R (All versions > V3.0), SIMATIC RF685R (All versions > V3.0). Affected devices do not properly handle large numbers of incoming connections. An attacker may leverage this to cause a Denial-of-Service situation.\n"
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-787292.pdf"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,70 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "productcert@siemens.com",
|
||||
"ID": "CVE-2021-31342",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2021-31342",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"data_type": "CVE",
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"vendor_name": "Siemens",
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "Solid Edge SE2020",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All Versions < 2020MP14"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "Solid Edge SE2021",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All Versions < SE2021MP5"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-787: Out-of-bounds Write"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions < 2020MP14), Solid Edge SE2021 (All Versions < SE2021MP5). The ugeom2d.dll library lacks proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure.\nAn attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12993)\n"
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208356.pdf"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,70 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "productcert@siemens.com",
|
||||
"ID": "CVE-2021-31343",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2021-31343",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"data_type": "CVE",
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"vendor_name": "Siemens",
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "Solid Edge SE2020",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All Versions < 2020MP14"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "Solid Edge SE2021",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All Versions < SE2021MP5"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-787: Out-of-bounds Write"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions < 2020MP14), Solid Edge SE2021 (All Versions < SE2021MP5). The jutil.dll library lacks proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure.\nAn attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12994)\n"
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208356.pdf"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,60 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "productcert@siemens.com",
|
||||
"ID": "CVE-2021-33712",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2021-33712",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"data_type": "CVE",
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"vendor_name": "Siemens",
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "Mendix SAML Module",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions < V2.1.2"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-345: Insufficient Verification of Data Authenticity"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "A vulnerability has been identified in Mendix SAML Module (All versions < V2.1.2). The configuration of the SAML module does not properly check various restrictions and validations imposed by an identity provider.\n\nThis could allow a remote authenticated attacker to escalate privileges.\n"
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-522654.pdf"
|
||||
}
|
||||
]
|
||||
}
|
||||
|