@ -1,17 +1,127 @@
|
||||
{
|
||||
"data_version": "4.0",
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2024-3506",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ASSIGNER": "psirt@milestonesys.com",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "A possible buffer overflow in selected cameras' drivers from XProtect Device Pack can allow an attacker with access to internal network to execute commands on Recording Server under strict conditions."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')",
|
||||
"cweId": "CWE-120"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"vendor_name": "Milestone Systems",
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "XProtect VMS",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "<=",
|
||||
"version_name": "0",
|
||||
"version_value": "13.1a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://supportcommunity.milestonesys.com/KBRedir?art=000065801&lang=en_US",
|
||||
"refsource": "MISC",
|
||||
"name": "https://supportcommunity.milestonesys.com/KBRedir?art=000065801&lang=en_US"
|
||||
}
|
||||
]
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.2.0"
|
||||
},
|
||||
"source": {
|
||||
"discovery": "EXTERNAL"
|
||||
},
|
||||
"work_around": [
|
||||
{
|
||||
"lang": "en",
|
||||
"supportingMedia": [
|
||||
{
|
||||
"base64": false,
|
||||
"type": "text/html",
|
||||
"value": "If, for any reason, patching is not possible, you should proceed with caution when adding new cameras and \nscan only IPs which are confirmed to be valid and trusted devices.\n\n<br>"
|
||||
}
|
||||
],
|
||||
"value": "If, for any reason, patching is not possible, you should proceed with caution when adding new cameras and \nscan only IPs which are confirmed to be valid and trusted devices."
|
||||
}
|
||||
],
|
||||
"exploit": [
|
||||
{
|
||||
"lang": "en",
|
||||
"supportingMedia": [
|
||||
{
|
||||
"base64": false,
|
||||
"type": "text/html",
|
||||
"value": "No public PoC or exploit \nis known.\n\n<br>"
|
||||
}
|
||||
],
|
||||
"value": "No public PoC or exploit \nis known."
|
||||
}
|
||||
],
|
||||
"solution": [
|
||||
{
|
||||
"lang": "en",
|
||||
"supportingMedia": [
|
||||
{
|
||||
"base64": false,
|
||||
"type": "text/html",
|
||||
"value": "<span style=\"background-color: rgb(255, 255, 255);\">To mitigate the issue, we highly recommend installing the XProtect Device Pack version 13.2a or later which contains the most up to date device drivers.</span><br>"
|
||||
}
|
||||
],
|
||||
"value": "To mitigate the issue, we highly recommend installing the XProtect Device Pack version 13.2a or later which contains the most up to date device drivers."
|
||||
}
|
||||
],
|
||||
"impact": {
|
||||
"cvss": [
|
||||
{
|
||||
"attackComplexity": "HIGH",
|
||||
"attackVector": "ADJACENT_NETWORK",
|
||||
"availabilityImpact": "LOW",
|
||||
"baseScore": 6.7,
|
||||
"baseSeverity": "MEDIUM",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "REQUIRED",
|
||||
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L",
|
||||
"version": "3.1"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
18
2024/48xxx/CVE-2024-48018.json
Normal file
18
2024/48xxx/CVE-2024-48018.json
Normal file
@ -0,0 +1,18 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2024-48018",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
@ -1,17 +1,87 @@
|
||||
{
|
||||
"data_version": "4.0",
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2024-8422",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ASSIGNER": "cybersecurity@schneider-electric.com",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution, denial\nof service and loss of confidentiality & integrity when application user opens a malicious Zelio\nSoft 2 project file."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-416 Use After Free",
|
||||
"cweId": "CWE-416"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"vendor_name": "Schneider Electric",
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "Zelio Soft 2",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_value": "Versions prior to 5.4.2.2"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-06&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-282-06.pdf",
|
||||
"refsource": "MISC",
|
||||
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-06&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-282-06.pdf"
|
||||
}
|
||||
]
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.2.0"
|
||||
},
|
||||
"source": {
|
||||
"discovery": "UNKNOWN"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": [
|
||||
{
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "LOCAL",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 7.8,
|
||||
"baseSeverity": "HIGH",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "REQUIRED",
|
||||
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,87 @@
|
||||
{
|
||||
"data_version": "4.0",
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2024-8518",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ASSIGNER": "cybersecurity@schneider-electric.com",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "CWE-20: Improper Input Validation vulnerability exists that could cause a crash of the Zelio Soft\n2 application when a specially crafted project file is loaded by an application user."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-20 Improper Input Validation",
|
||||
"cweId": "CWE-20"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"vendor_name": "Schneider Electric",
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "Zelio Soft 2",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_value": "Versions prior to 5.4.2.2"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-06&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-282-06.pdf",
|
||||
"refsource": "MISC",
|
||||
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-06&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-282-06.pdf"
|
||||
}
|
||||
]
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.2.0"
|
||||
},
|
||||
"source": {
|
||||
"discovery": "UNKNOWN"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": [
|
||||
{
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "LOCAL",
|
||||
"availabilityImpact": "LOW",
|
||||
"baseScore": 3.3,
|
||||
"baseSeverity": "LOW",
|
||||
"confidentialityImpact": "NONE",
|
||||
"integrityImpact": "NONE",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "REQUIRED",
|
||||
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
|
||||
"version": "3.1"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,98 @@
|
||||
{
|
||||
"data_version": "4.0",
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2024-8884",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ASSIGNER": "cybersecurity@schneider-electric.com",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that\ncould cause exposure of credentials when attacker has access to application on network over\nhttp"
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
|
||||
"cweId": "CWE-200"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"vendor_name": "Schneider Electric",
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "System Monitor application in Harmony Industrial PC HMIBMO/HMIBMI/HMIPSO/HMIBMP/HMIBMU/HMIPSP/HMIPEP series",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_value": "All versions"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "System Monitor application in Pro-face Industrial PC PS5000 series",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_value": "All versions"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-07&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-282-07.pdf",
|
||||
"refsource": "MISC",
|
||||
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-07&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-282-07.pdf"
|
||||
}
|
||||
]
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.2.0"
|
||||
},
|
||||
"source": {
|
||||
"discovery": "UNKNOWN"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": [
|
||||
{
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 9.8,
|
||||
"baseSeverity": "CRITICAL",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "NONE",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,87 @@
|
||||
{
|
||||
"data_version": "4.0",
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2024-9005",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ASSIGNER": "cybersecurity@schneider-electric.com",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "CWE-502: Deserialization of Untrusted Data vulnerability exists that could allow code to be\nremotely executed on the server when unsafely deserialized data is posted to the web server."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-502 Deserialization of Untrusted Data",
|
||||
"cweId": "CWE-502"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"vendor_name": "Schneider Electric",
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "EcoStruxure Power Monitoring Expert (PME)",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_value": "Version 2022 and prior"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-282-05.pdf",
|
||||
"refsource": "MISC",
|
||||
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-282-05.pdf"
|
||||
}
|
||||
]
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.2.0"
|
||||
},
|
||||
"source": {
|
||||
"discovery": "UNKNOWN"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": [
|
||||
{
|
||||
"attackComplexity": "HIGH",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 7.1,
|
||||
"baseSeverity": "HIGH",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "LOW",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "REQUIRED",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
Loading…