update to CVE-2023-27982

This commit is contained in:
Girish Kolla 2023-03-21 11:41:29 +05:30
parent 1ee2998494
commit 295fb6417f

View File

@ -1,18 +1,109 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@se.com",
"ID": "CVE-2023-27982",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "IGSS Data Server(IGSSdataServer.exe)",
"version": {
"version_data": [
{
"version_affected": "<=",
"version_name": "V",
"version_value": "16.0.0.23040"
}
]
}
},
{
"product_name": "IGSS Dashboard (DashBoard.exe)",
"version": {
"version_data": [
{
"version_affected": "<=",
"version_name": "V",
"version_value": "16.0.0.23040"
}
]
}
},
{
"product_name": "Custom Reports (RMS16.dll)",
"version": {
"version_data": [
{
"version_affected": "<=",
"version_name": "V",
"version_value": "16.0.0.23040"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause manipulation of dashboard files in the IGSS project report directory, when an attacker sends specific crafted messages to the Data Server TCP port, this could lead to remote code execution when a victim eventually opens a malicious dashboard file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-345 Insufficient Verification of Data Authenticity"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-04.pdf"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}