mirror of
https://github.com/CVEProject/cvelist.git
synced 2025-08-04 08:44:25 +00:00
"-Synchronized-Data."
This commit is contained in:
parent
f40520c5b1
commit
34690e68a3
@ -48,6 +48,11 @@
|
||||
"refsource": "MISC",
|
||||
"name": "https://support.hp.com/us-en/document/ish_5585999-5586023-16",
|
||||
"url": "https://support.hp.com/us-en/document/ish_5585999-5586023-16"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2022/MNDT-2022-0030/MNDT-2022-0030.md",
|
||||
"url": "https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2022/MNDT-2022-0030/MNDT-2022-0030.md"
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -48,6 +48,11 @@
|
||||
"refsource": "MISC",
|
||||
"name": "https://support.hp.com/us-en/document/ish_5585999-5586023-16",
|
||||
"url": "https://support.hp.com/us-en/document/ish_5585999-5586023-16"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2022/MNDT-2022-0030/MNDT-2022-0030.md",
|
||||
"url": "https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2022/MNDT-2022-0030/MNDT-2022-0030.md"
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -48,6 +48,11 @@
|
||||
"refsource": "MISC",
|
||||
"name": "https://support.hp.com/us-en/document/ish_5585999-5586023-16",
|
||||
"url": "https://support.hp.com/us-en/document/ish_5585999-5586023-16"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2022/MNDT-2022-0030/MNDT-2022-0030.md",
|
||||
"url": "https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2022/MNDT-2022-0030/MNDT-2022-0030.md"
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -48,6 +48,11 @@
|
||||
"refsource": "MISC",
|
||||
"name": "https://support.hp.com/us-en/document/ish_5585999-5586023-16",
|
||||
"url": "https://support.hp.com/us-en/document/ish_5585999-5586023-16"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2022/MNDT-2022-0030/MNDT-2022-0030.md",
|
||||
"url": "https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2022/MNDT-2022-0030/MNDT-2022-0030.md"
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -48,6 +48,11 @@
|
||||
"refsource": "MISC",
|
||||
"name": "https://support.hp.com/us-en/document/ish_5585999-5586023-16",
|
||||
"url": "https://support.hp.com/us-en/document/ish_5585999-5586023-16"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2022/MNDT-2022-0030/MNDT-2022-0030.md",
|
||||
"url": "https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2022/MNDT-2022-0030/MNDT-2022-0030.md"
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -48,6 +48,11 @@
|
||||
"refsource": "MISC",
|
||||
"name": "https://support.hp.com/us-en/document/ish_5585999-5586023-16",
|
||||
"url": "https://support.hp.com/us-en/document/ish_5585999-5586023-16"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2022/MNDT-2022-0030/MNDT-2022-0030.md",
|
||||
"url": "https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2022/MNDT-2022-0030/MNDT-2022-0030.md"
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -1,18 +1,105 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
||||
"DATE_PUBLIC": "2022-04-12T17:00:00.000Z",
|
||||
"ID": "CVE-2022-1264",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC",
|
||||
"TITLE": "Inductive Automation Ignition"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "Ignition",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": ">",
|
||||
"version_name": "All 8.0 versions",
|
||||
"version_value": "8.0.4"
|
||||
},
|
||||
{
|
||||
"version_name": "All 8.1 versions",
|
||||
"version_value": "8.1.10"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "Inductive Automation"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"credit": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
|
||||
}
|
||||
],
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "The affected product may allow an attacker with access to the Ignition web configuration to run arbitrary code."
|
||||
}
|
||||
]
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "NONE",
|
||||
"baseScore": 6.8,
|
||||
"baseSeverity": "MEDIUM",
|
||||
"confidentialityImpact": "NONE",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "HIGH",
|
||||
"scope": "CHANGED",
|
||||
"userInteraction": "NONE",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:H/A:N",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-102-03",
|
||||
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-102-03"
|
||||
}
|
||||
]
|
||||
},
|
||||
"solution": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Inductive Automation recommends users upgrade the Ignition software to 8.1.10 or later."
|
||||
}
|
||||
],
|
||||
"source": {
|
||||
"advisory": "ICSA-22-102-03",
|
||||
"discovery": "UNKNOWN"
|
||||
}
|
||||
}
|
@ -1,18 +1,99 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
||||
"DATE_PUBLIC": "2022-07-19T20:09:00.000Z",
|
||||
"ID": "CVE-2022-2107",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC",
|
||||
"TITLE": "ICSA-22-200-01 MiCODUS MV720 GPS tracker Use of Hard-coded Credentials"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "MV720",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_value": "All versions"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "MiCODUS"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"credit": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Pedro Umbelino, Dan Dahlberg, and Jacob Olcott of BitSight reported these vulnerabilities to CISA."
|
||||
}
|
||||
],
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "The MiCODUS MV720 GPS tracker API server has an authentication mechanism that allows devices to use a hard-coded master password. This may allow an attacker to send SMS commands directly to the GPS tracker as if they were coming from the GPS owner\u2019s mobile number."
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 9.8,
|
||||
"baseSeverity": "CRITICAL",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "NONE",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-798 Use of Hard-coded Credentials"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-200-01",
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-200-01"
|
||||
}
|
||||
]
|
||||
},
|
||||
"source": {
|
||||
"discovery": "EXTERNAL"
|
||||
},
|
||||
"work_around": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "As of July 18th, 2022, MiCODUS has not provided updates or patches to mitigate these vulnerabilities. CISA will update the corresponding ICSA to reflect any patches, updates, or mitigation information provided by MiCODUS in the future."
|
||||
}
|
||||
]
|
||||
}
|
@ -1,18 +1,99 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
||||
"DATE_PUBLIC": "2022-07-19T20:09:00.000Z",
|
||||
"ID": "CVE-2022-2141",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC",
|
||||
"TITLE": "ICSA-22-200-01 MiCODUS MV720 GPS tracker Improper Authentication"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "MV720",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_value": "All versions"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "MiCODUS"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"credit": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Pedro Umbelino, Dan Dahlberg, and Jacob Olcott of BitSight reported these vulnerabilities to CISA."
|
||||
}
|
||||
],
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "SMS-based GPS commands can be executed by MiCODUS MV720 GPS tracker without authentication."
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 9.8,
|
||||
"baseSeverity": "CRITICAL",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "NONE",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-287 Improper Authentication"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-200-01",
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-200-01"
|
||||
}
|
||||
]
|
||||
},
|
||||
"source": {
|
||||
"discovery": "EXTERNAL"
|
||||
},
|
||||
"work_around": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "As of July 18th, 2022, MiCODUS has not provided updates or patches to mitigate these vulnerabilities. CISA will update the corresponding ICSA to reflect any patches, updates, or mitigation information provided by MiCODUS in the future."
|
||||
}
|
||||
]
|
||||
}
|
@ -1,18 +1,115 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
||||
"DATE_PUBLIC": "2022-07-19T20:09:00.000Z",
|
||||
"ID": "CVE-2022-2179",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC",
|
||||
"TITLE": "ICSA-22-188-01 Rockwell Automation MicroLogix Improper Restriction of Rendered UI Layers or Frames"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "MicroLogix 1400",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "<=",
|
||||
"version_value": "21.007"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "MicroLogix 1100",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_value": "All versions"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "Rockwell Automation"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"credit": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Pawan V. Sable and Pranita Binnar from Veermata Jijabai Technological Institute (VJTI) reported this vulnerability to Rockwell Automation."
|
||||
}
|
||||
],
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "The X-Frame-Options header in Rockwell Automation MicroLogix 1100/1400 Versions 21.007 and prior is not configured in the HTTP response, which could allow clickjacking attacks."
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "NONE",
|
||||
"baseScore": 6.5,
|
||||
"baseSeverity": "MEDIUM",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "NONE",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "REQUIRED",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-1021"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-188-01",
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-188-01"
|
||||
},
|
||||
{
|
||||
"name": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1135994",
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1135994"
|
||||
}
|
||||
]
|
||||
},
|
||||
"source": {
|
||||
"discovery": "EXTERNAL"
|
||||
},
|
||||
"work_around": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Rockwell Automation encourages those using the affected software to implement the mitigations below to minimize risk. Additionally, Rockwell Automation encourages users to combine risk mitigations with security best practices (also provided below) to deploy a defense-in-depth strategy.\n\n Disable the web server where possible (this component is an optional feature and disabling it will not disrupt the intended use of the device).\n Configure firewalls to disallow network communication through HTTP/Port 80\n\nIf applying the mitigations noted above are not possible, please see Rockwell Automation\u2019s Knowledgebase article QA43240 Security Best Practices.\n\nFor more information, please see the industrial security advisory from Rockwell Automation."
|
||||
}
|
||||
]
|
||||
}
|
@ -1,18 +1,99 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
||||
"DATE_PUBLIC": "2022-07-19T20:09:00.000Z",
|
||||
"ID": "CVE-2022-2199",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC",
|
||||
"TITLE": "ICSA-22-200-01 MiCODUS MV720 GPS tracker Cross-site Scripting"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "MV720",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_value": "All versions"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "MiCODUS"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"credit": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Pedro Umbelino, Dan Dahlberg, and Jacob Olcott of BitSight reported these vulnerabilities to CISA."
|
||||
}
|
||||
],
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "The main MiCODUS MV720 GPS tracker web server has a reflected cross-site scripting vulnerability that could allow an attacker to gain control by tricking a user into making a request."
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "HIGH",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 7.5,
|
||||
"baseSeverity": "HIGH",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "REQUIRED",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-79 Cross-site Scripting"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-200-01",
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-200-01"
|
||||
}
|
||||
]
|
||||
},
|
||||
"source": {
|
||||
"discovery": "EXTERNAL"
|
||||
},
|
||||
"work_around": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "As of July 18th, 2022, MiCODUS has not provided updates or patches to mitigate these vulnerabilities. CISA will update the corresponding ICSA to reflect any patches, updates, or mitigation information provided by MiCODUS in the future."
|
||||
}
|
||||
]
|
||||
}
|
@ -1,18 +1,99 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
||||
"DATE_PUBLIC": "2022-07-19T20:09:00.000Z",
|
||||
"ID": "CVE-2022-33944",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC",
|
||||
"TITLE": "ICSA-22-200-01 MiCODUS MV720 GPS tracker Authorization Bypass Through User-Controlled Key"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "MV720",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_value": "All versions"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "MiCODUS"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"credit": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Pedro Umbelino, Dan Dahlberg, and Jacob Olcott of BitSight reported these vulnerabilities to CISA."
|
||||
}
|
||||
],
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "The main MiCODUS MV720 GPS tracker web server has an authenticated insecure direct object references vulnerability on endpoint and POST parameter \u201cDevice ID,\u201d which accepts arbitrary device IDs."
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "NONE",
|
||||
"baseScore": 6.5,
|
||||
"baseSeverity": "MEDIUM",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "NONE",
|
||||
"privilegesRequired": "LOW",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "NONE",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-639 Authorization Bypass Through User-Controlled Key"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-200-01",
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-200-01"
|
||||
}
|
||||
]
|
||||
},
|
||||
"source": {
|
||||
"discovery": "EXTERNAL"
|
||||
},
|
||||
"work_around": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "As of July 18th, 2022, MiCODUS has not provided updates or patches to mitigate these vulnerabilities. CISA will update the corresponding ICSA to reflect any patches, updates, or mitigation information provided by MiCODUS in the future."
|
||||
}
|
||||
]
|
||||
}
|
@ -1,18 +1,99 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
||||
"DATE_PUBLIC": "2022-07-19T20:09:00.000Z",
|
||||
"ID": "CVE-2022-34150",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC",
|
||||
"TITLE": "ICSA-22-200-01 MiCODUS MV720 GPS tracker Authorization Bypass Through User-Controlled Key"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "MV720",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_value": "All versions"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "MiCODUS"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"credit": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Pedro Umbelino, Dan Dahlberg, and Jacob Olcott of BitSight reported these vulnerabilities to CISA."
|
||||
}
|
||||
],
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "The main MiCODUS MV720 GPS tracker web server has an authenticated insecure direct object reference vulnerability on endpoint and parameter device IDs, which accept arbitrary device IDs without further verification."
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "NONE",
|
||||
"baseScore": 7.1,
|
||||
"baseSeverity": "HIGH",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "LOW",
|
||||
"privilegesRequired": "LOW",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "NONE",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-639 Authorization Bypass Through User-Controlled Key"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-200-01",
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-200-01"
|
||||
}
|
||||
]
|
||||
},
|
||||
"source": {
|
||||
"discovery": "EXTERNAL"
|
||||
},
|
||||
"work_around": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "As of July 18th, 2022, MiCODUS has not provided updates or patches to mitigate these vulnerabilities. CISA will update the corresponding ICSA to reflect any patches, updates, or mitigation information provided by MiCODUS in the future."
|
||||
}
|
||||
]
|
||||
}
|
Loading…
x
Reference in New Issue
Block a user