- Added submission from Siemens from 2018-12-11.

This commit is contained in:
CVE Team 2018-12-12 10:07:26 -05:00
parent 765c96b0e7
commit 3a1406a240
No known key found for this signature in database
GPG Key ID: 0DA1F9F56BC892E8
11 changed files with 597 additions and 33 deletions

View File

@ -1,8 +1,37 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "productcert@siemens.com",
"ID" : "CVE-2018-11457",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8",
"version" : {
"version_data" : [
{
"version_value" : "SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1"
},
{
"version_value" : "SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5"
},
{
"version_value" : "SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3"
}
]
}
}
]
},
"vendor_name" : "Siemens AG"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +40,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 4842/tcp. Please note that this vulnerability is only exploitable if port 4842/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices on port 4842/tcp. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the web server. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
}
]
}

View File

@ -1,8 +1,37 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "productcert@siemens.com",
"ID" : "CVE-2018-11458",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8",
"version" : {
"version_data" : [
{
"version_value" : "SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1"
},
{
"version_value" : "SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5"
},
{
"version_value" : "SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3"
}
]
}
}
]
},
"vendor_name" : "Siemens AG"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +40,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 5900/tcp. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "CWE-190: Integer Overflow or Wraparound"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
}
]
}

View File

@ -1,8 +1,43 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "productcert@siemens.com",
"ID" : "CVE-2018-11459",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8",
"version" : {
"version_data" : [
{
"version_value" : "SINUMERIK 808D V4.7 : All versions"
},
{
"version_value" : "SINUMERIK 808D V4.8 : All versions"
},
{
"version_value" : "SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1"
},
{
"version_value" : "SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5"
},
{
"version_value" : "SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3"
}
]
}
}
]
},
"vendor_name" : "Siemens AG"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +46,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker could modify a user-writeable configuration file so that after reboot or manual initiation the system reloads the modified configuration file and attacker-controlled code is executed with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "CWE-693: Protection Mechanism Failure"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
}
]
}

View File

@ -1,8 +1,43 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "productcert@siemens.com",
"ID" : "CVE-2018-11460",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8",
"version" : {
"version_data" : [
{
"version_value" : "SINUMERIK 808D V4.7 : All versions"
},
{
"version_value" : "SINUMERIK 808D V4.8 : All versions"
},
{
"version_value" : "SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1"
},
{
"version_value" : "SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5"
},
{
"version_value" : "SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3"
}
]
}
}
]
},
"vendor_name" : "Siemens AG"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +46,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with elevated user privileges (manufact) could modify a CRAMFS archive so that after reboot the system loads the modified CRAMFS file and attacker-controlled code is executed with root privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires elevated user privileges (manufact) but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "CWE-693: Protection Mechanism Failure"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
}
]
}

View File

@ -1,8 +1,43 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "productcert@siemens.com",
"ID" : "CVE-2018-11461",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8",
"version" : {
"version_data" : [
{
"version_value" : "SINUMERIK 808D V4.7 : All versions"
},
{
"version_value" : "SINUMERIK 808D V4.8 : All versions"
},
{
"version_value" : "SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1"
},
{
"version_value" : "SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5"
},
{
"version_value" : "SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3"
}
]
}
}
]
},
"vendor_name" : "Siemens AG"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +46,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with user privileges could use the service command application for privilege escalation to an elevated user but not root. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "CWE-264: Permissions, Privileges, and Access Controls"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
}
]
}

View File

@ -1,8 +1,43 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "productcert@siemens.com",
"ID" : "CVE-2018-11462",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8",
"version" : {
"version_data" : [
{
"version_value" : "SINUMERIK 808D V4.7 : All versions"
},
{
"version_value" : "SINUMERIK 808D V4.8 : All versions"
},
{
"version_value" : "SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1"
},
{
"version_value" : "SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5"
},
{
"version_value" : "SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3"
}
]
}
}
]
},
"vendor_name" : "Siemens AG"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +46,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). By sending a specially crafted authentication request to the affected systems a remote attacker could escalate his privileges to an elevated user account but not to root. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "CWE-264: Permissions, Privileges, and Access Controls"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
}
]
}

View File

@ -1,8 +1,43 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "productcert@siemens.com",
"ID" : "CVE-2018-11463",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8",
"version" : {
"version_data" : [
{
"version_value" : "SINUMERIK 808D V4.7 : All versions"
},
{
"version_value" : "SINUMERIK 808D V4.8 : All versions"
},
{
"version_value" : "SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1"
},
{
"version_value" : "SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5"
},
{
"version_value" : "SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3"
}
]
}
}
]
},
"vendor_name" : "Siemens AG"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +46,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A buffer overflow in the service command application could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "CWE-121: Stack-based Buffer Overflow"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
}
]
}

View File

@ -1,8 +1,37 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "productcert@siemens.com",
"ID" : "CVE-2018-11464",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8",
"version" : {
"version_data" : [
{
"version_value" : "SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1"
},
{
"version_value" : "SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5"
},
{
"version_value" : "SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3"
}
]
}
}
]
},
"vendor_name" : "Siemens AG"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +40,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "CWE-248: Uncaught Exception"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
}
]
}

View File

@ -1,8 +1,43 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "productcert@siemens.com",
"ID" : "CVE-2018-11465",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8",
"version" : {
"version_data" : [
{
"version_value" : "SINUMERIK 808D V4.7 : All versions"
},
{
"version_value" : "SINUMERIK 808D V4.8 : All versions"
},
{
"version_value" : "SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1"
},
{
"version_value" : "SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5"
},
{
"version_value" : "SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3"
}
]
}
}
]
},
"vendor_name" : "Siemens AG"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +46,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker could use ioctl calls to do out of bounds reads, arbitrary writes, or execute code in kernel mode. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "CWE-248: Uncaught Exception"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
}
]
}

View File

@ -1,8 +1,43 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "productcert@siemens.com",
"ID" : "CVE-2018-11466",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8",
"version" : {
"version_data" : [
{
"version_value" : "SINUMERIK 808D V4.7 : All versions"
},
{
"version_value" : "SINUMERIK 808D V4.8 : All versions"
},
{
"version_value" : "SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1"
},
{
"version_value" : "SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5"
},
{
"version_value" : "SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3"
}
]
}
}
]
},
"vendor_name" : "Siemens AG"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +46,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). Specially crafted network packets sent to port 102/tcp (ISO-TSAP) could allow a remote attacker to either cause a Denial-of-Service condition of the integrated software firewall or allow to execute code in the context of the software firewall. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 102/tcp. Successful exploitation requires no user privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known"
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "CWE-248: Uncaught Exception"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
}
]
}

View File

@ -1,8 +1,31 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "productcert@siemens.com",
"ID" : "CVE-2018-13816",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "TIM 1531 IRC",
"version" : {
"version_data" : [
{
"version_value" : "TIM 1531 IRC : All version < V2.0"
}
]
}
}
]
},
"vendor_name" : "Siemens AG"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +34,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability has been identified in TIM 1531 IRC (All version < V2.0). The devices was missing proper authentication on port 102/tcp, although configured. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. At the time of advisory publication no public exploitation of this vulnerability was known."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "CWE-284: Improper Access Control"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://cert-portal.siemens.com/productcert/pdf/ssa-982399.pdf"
}
]
}