mirror of
https://github.com/CVEProject/cvelist.git
synced 2025-07-29 05:56:59 +00:00
"-Synchronized-Data."
This commit is contained in:
parent
5f79a39e75
commit
45c945f1f7
@ -1,37 +1,12 @@
|
||||
{
|
||||
"data_version": "4.0",
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "secure@dell.com",
|
||||
"DATE_PUBLIC": "2022-01-31",
|
||||
"ID": "CVE-2022-22549",
|
||||
"ASSIGNER": "secure@dell.com",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "PowerScale OneFS",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_value": "8.2.x-9.3.x"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "Dell"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
@ -40,32 +15,73 @@
|
||||
}
|
||||
]
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"baseScore": 7.5,
|
||||
"baseSeverity": "High",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-295: Improper Certificate Validation"
|
||||
"value": "CWE-295: Improper Certificate Validation",
|
||||
"cweId": "CWE-295"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"vendor_name": "Dell",
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "PowerScale OneFS",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "8.2.x-9.3.x",
|
||||
"version_affected": "="
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://www.dell.com/support/kbdoc/en-us/000195815/dsa-2022-002-dell-emc-powerscale-onefs-security-update-for-multiple-vulnerabilities",
|
||||
"refsource": "MISC",
|
||||
"url": "https://www.dell.com/support/kbdoc/000195815",
|
||||
"name": "https://www.dell.com/support/kbdoc/000195815"
|
||||
"name": "https://www.dell.com/support/kbdoc/en-us/000195815/dsa-2022-002-dell-emc-powerscale-onefs-security-update-for-multiple-vulnerabilities"
|
||||
}
|
||||
]
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.1.0-dev"
|
||||
},
|
||||
"source": {
|
||||
"discovery": "UNKNOWN"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": [
|
||||
{
|
||||
"attackComplexity": "HIGH",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 7.5,
|
||||
"baseSeverity": "HIGH",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "REQUIRED",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,87 @@
|
||||
{
|
||||
"data_version": "4.0",
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2022-24410",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ASSIGNER": "secure@dell.com",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Dell BIOS contains an information exposure vulnerability. An unauthenticated local attacker with physical access to the system and knowledge of the system configuration could potentially exploit this vulnerability to read system information via debug interfaces."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
|
||||
"cweId": "CWE-200"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"vendor_name": "Dell",
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "CPG BIOS",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All supported versions",
|
||||
"version_affected": "="
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://www.dell.com/support/kbdoc/en-us/000205719/dsa-2022-325",
|
||||
"refsource": "MISC",
|
||||
"name": "https://www.dell.com/support/kbdoc/en-us/000205719/dsa-2022-325"
|
||||
}
|
||||
]
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.1.0-dev"
|
||||
},
|
||||
"source": {
|
||||
"discovery": "UNKNOWN"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": [
|
||||
{
|
||||
"attackComplexity": "HIGH",
|
||||
"attackVector": "PHYSICAL",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 6.8,
|
||||
"baseSeverity": "MEDIUM",
|
||||
"confidentialityImpact": "NONE",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "CHANGED",
|
||||
"userInteraction": "NONE",
|
||||
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:C/C:N/I:H/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
Loading…