"-Synchronized-Data."

This commit is contained in:
CVE Team 2020-03-23 20:01:15 +00:00
parent 9d0da939ac
commit 4a9e6021b8
No known key found for this signature in database
GPG Key ID: 5708902F06FEF743
13 changed files with 611 additions and 31 deletions

View File

@ -1,17 +1,61 @@
{
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-6560",
"STATE": "RESERVED"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2019-6560",
"ASSIGNER": "ics-cert@hq.dhs.gov",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "Auto-Maskin RP210E Versions 3.7 and prior DCU210E Versions 3.7 and prior and Marine Observer Pro (Android App)",
"version": {
"version_data": [
{
"version_value": "Auto-Maskin RP210E Versions 3.7 and prior DCU210E Versions 3.7 and prior and Marine Observer Pro (Android App)"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "WEAK PASSWORD RECOVERY MECHANISM FOR FORGOTTEN PASSWORD CWE-640"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-051-04",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-051-04"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "In Auto-Maskin RP210E Versions 3.7 and prior, DCU210E Versions 3.7 and prior and Marine Observer Pro (Android App), the software contains a mechanism for users to recover or change their passwords without knowing the original password, but the mechanism is weak."
}
]
}

View File

@ -0,0 +1,76 @@
{
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-10870",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Zim through 0.72.1 creates temporary directories with predictable names. A malicious user could predict and create Zim's temporary directories and prevent other users from being able to start Zim, resulting in a denial of service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"url": "https://github.com/zim-desktop-wiki/zim-desktop-wiki/issues/1028",
"refsource": "MISC",
"name": "https://github.com/zim-desktop-wiki/zim-desktop-wiki/issues/1028"
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:L/A:H/C:N/I:N/PR:L/S:U/UI:N",
"version": "3.0"
}
}
}

View File

@ -0,0 +1,72 @@
{
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-10871",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "** DISPUTED ** In OpenWrt LuCI git-20.x, remote unauthenticated attackers can retrieve the list of installed packages and services. NOTE: the vendor disputes the significance of this report because, for instances reachable by an unauthenticated actor, the same information is available in other (more complex) ways, and there is no plan to restrict the information further."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"url": "https://github.com/openwrt/luci/issues/3563#issuecomment-578522860",
"refsource": "MISC",
"name": "https://github.com/openwrt/luci/issues/3563#issuecomment-578522860"
},
{
"url": "https://github.com/openwrt/luci/issues/3653#issue-567892007",
"refsource": "MISC",
"name": "https://github.com/openwrt/luci/issues/3653#issue-567892007"
},
{
"url": "https://github.com/openwrt/luci/issues/3766",
"refsource": "MISC",
"name": "https://github.com/openwrt/luci/issues/3766"
}
]
}
}

View File

@ -0,0 +1,18 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-10872",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
}
]
}
}

View File

@ -0,0 +1,18 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-10873",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
}
]
}
}

View File

@ -4,14 +4,58 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-5722",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "vulnreport@tenable.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "Grandstream UCM6200 Series",
"version": {
"version_data": [
{
"version_value": "Before 1.0.20.17"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "SQL Injection, HTML Injection"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://www.tenable.com/security/research/tra-2020-15",
"url": "https://www.tenable.com/security/research/tra-2020-15"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "The HTTP interface of the Grandstream UCM6200 series is vulnerable to an unauthenticated remote SQL injection via crafted HTTP request. An attacker can use this vulnerability to execute shell commands as root on versions before 1.0.19.20 or inject HTML in password recovery emails in versions before 1.0.20.17."
}
]
}

View File

@ -4,14 +4,58 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-7476",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "cybersecurity@schneider-electric.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "ZigBee Installation Toolkit (Versions prior to 1.0.1)",
"version": {
"version_data": [
{
"version_value": "ZigBee Installation Toolkit (Versions prior to 1.0.1)"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-426: Untrusted Search Path"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-070-03",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-03"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A CWE-426: Untrusted Search Path vulnerability exists in ZigBee Installation Kit (Versions prior to 1.0.1), which could cause execution of malicious code when a malicious file is put in the search path."
}
]
}

View File

@ -4,14 +4,58 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-7477",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "cybersecurity@schneider-electric.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "Modicon Quantum Ethernet Network module and Quantum / Premium COPRO (Quantum Ethernet Network module 140NOE771x1, versions 7.0 and prior, Quantum processors with integrated Ethernet \u2013 140CPU65xxxxx, all versions, Premium processors with integrated Ethernet, all versions)",
"version": {
"version_data": [
{
"version_value": "Modicon Quantum Ethernet Network module and Quantum / Premium COPRO (Quantum Ethernet Network module 140NOE771x1, versions 7.0 and prior, Quantum processors with integrated Ethernet \u2013 140CPU65xxxxx, all versions, Premium processors with integrated Ethernet, all versions)"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-070-02/",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-02/"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Quantum Ethernet Network module 140NOE771x1 (Versions 7.0 and prior), Quantum processors with integrated Ethernet \u2013 140CPU65xxxxx (all Versions), and Premium processors with integrated Ethernet (all Versions), which could cause a Denial of Service when sending a specially crafted command over Modbus."
}
]
}

View File

@ -4,14 +4,58 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-7478",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "cybersecurity@schneider-electric.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "IGSS (Interactive Graphical SCADA System) (IGSS Version prior to 14.0.0.20009)",
"version": {
"version_data": [
{
"version_value": "IGSS (Interactive Graphical SCADA System) (Versions 14 and prior using the service: IGSSupdate)"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-070-01/",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-01/"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a remote unauthenticated attacker to read arbitrary files from the IGSS server PC on an unrestricted or shared network when the IGSS Update Service is enabled."
}
]
}

View File

@ -4,14 +4,58 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-7479",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "cybersecurity@schneider-electric.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "IGSS (Interactive Graphical SCADA System) (IGSS Version prior to 14.0.0.20009)",
"version": {
"version_data": [
{
"version_value": "IGSS (Interactive Graphical SCADA System) (Versions 14 and prior using the service: IGSSupdate)"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306: Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-070-01/",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-01/"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a local user to execute processes that otherwise require escalation privileges when sending local network commands to the IGSS Update Service."
}
]
}

View File

@ -4,14 +4,58 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-7480",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "cybersecurity@schneider-electric.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "Andover Continuum (All versions)",
"version": {
"version_data": [
{
"version_value": "Andover Continuum (All versions)"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-94: Improper Control of Generation of Code ('Code Injection')"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists in Andover Continuum (All versions), which could cause files on the application server filesystem to be viewable when an attacker interferes with an application's processing of XML data."
}
]
}

View File

@ -4,14 +4,58 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-7481",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "cybersecurity@schneider-electric.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "Andover Continuum (All versions)",
"version": {
"version_data": [
{
"version_value": "Andover Continuum (All versions)"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could enable a successful Cross-site Scripting (XSS attack) when using the products' web server."
}
]
}

View File

@ -4,14 +4,58 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-7482",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "cybersecurity@schneider-electric.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "Andover Continuum (All versions)",
"version": {
"version_data": [
{
"version_value": "Andover Continuum (All versions)"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could cause a Reflective Cross-site Scripting (XSS attack) when using the products' web server."
}
]
}