"-Synchronized-Data."

This commit is contained in:
CVE Team 2019-07-02 21:00:57 +00:00
parent e5383021a5
commit 4dc743441e
No known key found for this signature in database
GPG Key ID: 0DA1F9F56BC892E8
15 changed files with 818 additions and 51 deletions

View File

@ -2,7 +2,30 @@
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-11578",
"STATE": "RESERVED"
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
@ -11,7 +34,38 @@
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is connected to the Blipcare's device wireless network to easily sniff these values using a MITM attack."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "BUGTRAQ",
"name": "20190609 Newly releases IoT security issues",
"url": "https://seclists.org/bugtraq/2019/Jun/8"
},
{
"refsource": "MISC",
"name": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html",
"url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
},
{
"refsource": "MISC",
"name": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf",
"url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
}
]
}

View File

@ -2,7 +2,30 @@
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-11579",
"STATE": "RESERVED"
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
@ -11,7 +34,38 @@
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "In the most recent firmware for Blipcare, the device provides an open Wireless network called \"Blip\" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is in vicinity of Wireless signal generated by the Blipcare device to easily sniff the credentials. Also, an attacker can connect to the open wireless network \"Blip\" exposed by the device and modify the HTTP response presented to the user by the device to execute other attacks such as convincing the user to download and execute a malicious binary that would infect a user's computer or mobile device with malware."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "BUGTRAQ",
"name": "20190609 Newly releases IoT security issues",
"url": "https://seclists.org/bugtraq/2019/Jun/8"
},
{
"refsource": "MISC",
"name": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html",
"url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
},
{
"refsource": "MISC",
"name": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf",
"url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
}
]
}

View File

@ -2,7 +2,30 @@
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-11580",
"STATE": "RESERVED"
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
@ -11,7 +34,38 @@
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Service. When connected to the \"Blip\" open wireless connection provided by the device, if a large string is sent as a part of the HTTP request in any part of the HTTP headers, the device could become completely unresponsive. Presumably this happens as the memory footprint provided to this device is very small. According to the specs from Rezolt, the Wi-Fi module only has 256k of memory. As a result, an incorrect string copy operation using either memcpy, strcpy, or any of their other variants could result in filling up the memory space allocated to the function executing and this would result in memory corruption. To test the theory, one can modify the demo application provided by the Cypress WICED SDK and introduce an incorrect \"memcpy\" operation and use the compiled application on the evaluation board provided by Cypress semiconductors with exactly the same Wi-Fi SOC. The results were identical where the device would completely stop responding to any of the ping or web requests."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "BUGTRAQ",
"name": "20190609 Newly releases IoT security issues",
"url": "https://seclists.org/bugtraq/2019/Jun/8"
},
{
"refsource": "MISC",
"name": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html",
"url": "http://packetstormsecurity.com/files/153225/Blipcare-Clear-Text-Communication-Memory-Corruption.html"
},
{
"refsource": "MISC",
"name": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf",
"url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Blipcare_sec_issues.pdf"
}
]
}

View File

@ -2,7 +2,30 @@
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-8412",
"STATE": "RESERVED"
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
@ -11,7 +34,38 @@
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The device has a custom binary called mp4ts under the /var/www/video folder. It seems that this binary dumps the HTTP VERB in the system logs. As a part of doing that it retrieves the HTTP VERB sent by the user and uses a vulnerable sprintf function at address 0x0000C3D4 in the function sub_C210 to copy the value into a string and then into a log file. Since there is no bounds check being performed on the environment variable at address 0x0000C360 this results in a stack overflow and overwrites the PC register allowing an attacker to execute buffer overflow or even a command injection attack."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "BUGTRAQ",
"name": "20190609 Newly releases IoT security issues",
"url": "https://seclists.org/bugtraq/2019/Jun/8"
},
{
"refsource": "MISC",
"name": "http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html",
"url": "http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html"
},
{
"refsource": "MISC",
"name": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf",
"url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf"
}
]
}

View File

@ -2,7 +2,30 @@
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-8413",
"STATE": "RESERVED"
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
@ -11,7 +34,38 @@
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The device runs a custom daemon on UDP port 5978 which is called \"dldps2121\" and listens for broadcast packets sent on 255.255.255.255. This daemon handles custom D-Link UDP based protocol that allows D-Link mobile applications and desktop applications to discover D-Link devices on the local network. The binary processes the received UDP packets sent from any device in \"main\" function. One path in the function traverses towards a block of code that handles commands to be executed on the device. The custom protocol created by D-Link follows the following pattern: Packetlen, Type of packet; M=MAC address of device or broadcast; D=Device Type;C=base64 encoded command string;test=1111. If a packet is received with the packet type being \"S\" or 0x53 then the string passed in the \"C\" parameter is base64 decoded and then executed by passing into a System API. We can see at address 0x00009B44 that the string received in packet type subtracts 0x31 or \"1\" from the packet type and is compared against 0x22 or \"double quotes\". If that is the case, then the packet is sent towards the block of code that executes a command. Then the value stored in \"C\" parameter is extracted at address 0x0000A1B0. Finally, the string received is base 64 decoded and passed on to the system API at address 0x0000A2A8 as shown below. The same form of communication can be initiated by any process including an attacker process on the mobile phone or the desktop and this allows a third-party application on the device to execute commands on the device without any authentication by sending just 1 UDP packet with custom base64 encoding."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "BUGTRAQ",
"name": "20190609 Newly releases IoT security issues",
"url": "https://seclists.org/bugtraq/2019/Jun/8"
},
{
"refsource": "MISC",
"name": "http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html",
"url": "http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html"
},
{
"refsource": "MISC",
"name": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf",
"url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf"
}
]
}

View File

@ -2,7 +2,30 @@
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-8415",
"STATE": "RESERVED"
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
@ -11,7 +34,38 @@
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The device has a custom telnet daemon as a part of the busybox and retrieves the password from the shadow file using the function getspnam at address 0x00053894. Then performs a crypt operation on the password retrieved from the user at address 0x000538E0 and performs a strcmp at address 0x00053908 to check if the password is correct or incorrect. However, the /etc/shadow file is a part of CRAM-FS filesystem which means that the user cannot change the password and hence a hardcoded hash in /etc/shadow is used to match the credentials provided by the user. This is a salted hash of the string \"admin\" and hence it acts as a password to the device which cannot be changed as the whole filesystem is read only."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "BUGTRAQ",
"name": "20190609 Newly releases IoT security issues",
"url": "https://seclists.org/bugtraq/2019/Jun/8"
},
{
"refsource": "MISC",
"name": "http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html",
"url": "http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html"
},
{
"refsource": "MISC",
"name": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf",
"url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf"
}
]
}

View File

@ -2,7 +2,30 @@
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-8416",
"STATE": "RESERVED"
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
@ -11,7 +34,38 @@
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The device runs a custom daemon on UDP port 5978 which is called \"dldps2121\" and listens for broadcast packets sent on 255.255.255.255. This daemon handles custom D-Link UDP based protocol that allows D-Link mobile applications and desktop applications to discover D-Link devices on the local network. The binary processes the received UDP packets sent from any device in \"main\" function. One path in the function traverses towards a block of code that processing of packets which does an unbounded copy operation which allows to overflow the buffer. The custom protocol created by Dlink follows the following pattern: Packetlen, Type of packet; M=MAC address of device or broadcast; D=Device Type;C=base64 encoded command string;test=1111 We can see at address function starting at address 0x0000DBF8 handles the entire UDP packet and performs an insecure copy using strcpy function at address 0x0000DC88. This results in overflowing the stack pointer after 1060 characters and thus allows to control the PC register and results in code execution. The same form of communication can be initiated by any process including an attacker process on the mobile phone or the desktop and this allows a third-party application on the device to execute commands on the device without any authentication by sending just 1 UDP packet with custom base64 encoding."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "BUGTRAQ",
"name": "20190609 Newly releases IoT security issues",
"url": "https://seclists.org/bugtraq/2019/Jun/8"
},
{
"refsource": "MISC",
"name": "http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html",
"url": "http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html"
},
{
"refsource": "MISC",
"name": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf",
"url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf"
}
]
}

View File

@ -2,7 +2,30 @@
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-8417",
"STATE": "RESERVED"
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
@ -11,7 +34,38 @@
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The device requires that a user logging into the device provide a username and password. However, the device allows D-Link apps on the mobile devices and desktop to communicate with the device without any authentication. As a part of that communication, the device uses custom version of base64 encoding to pass data back and forth between the apps and the device. However, the same form of communication can be initiated by any process including an attacker process on the mobile phone or the desktop and this allows a third party to retrieve the device's password without any authentication by sending just 1 UDP packet with custom base64 encoding. The severity of this attack is enlarged by the fact that there more than 100,000 D-Link devices out there."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "BUGTRAQ",
"name": "20190609 Newly releases IoT security issues",
"url": "https://seclists.org/bugtraq/2019/Jun/8"
},
{
"refsource": "MISC",
"name": "http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html",
"url": "http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html"
},
{
"refsource": "MISC",
"name": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf",
"url": "https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Dlink_DCS_1130_security.pdf"
}
]
}

View File

@ -211,6 +211,11 @@
"url": "https://portal.msrc.microsoft.com/en-US/security-guidance/advisory/CVE-2019-0906",
"refsource": "MISC",
"name": "https://portal.msrc.microsoft.com/en-US/security-guidance/advisory/CVE-2019-0906"
},
{
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-19-624/",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-19-624/"
}
]
}

View File

@ -58,6 +58,11 @@
"refsource": "FEDORA",
"name": "FEDORA-2019-697de0501f",
"url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/SMG3V4VTX2SE3EW3HQTN3DDLQBTORQC2/"
},
{
"refsource": "CONFIRM",
"name": "https://support.f5.com/csp/article/K08125515",
"url": "https://support.f5.com/csp/article/K08125515"
}
]
},

View File

@ -1,17 +1,106 @@
{
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-5599",
"STATE": "RESERVED"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2019-5599",
"ASSIGNER": "secteam@freebsd.org",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "FreeBSD",
"version": {
"version_data": [
{
"version_value": "FreeBSD 12.0 before 12.0-RELEASE-p6"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Kernel resource exhaustion in network stack"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MLIST",
"name": "[oss-security] 20190617 Linux and FreeBSD Kernel: Multiple TCP-based remote denial of service issues",
"url": "http://www.openwall.com/lists/oss-security/2019/06/17/5"
},
{
"refsource": "MISC",
"name": "https://github.com/Netflix/security-bulletins/blob/master/advisories/third-party/2019-001.md",
"url": "https://github.com/Netflix/security-bulletins/blob/master/advisories/third-party/2019-001.md"
},
{
"refsource": "MISC",
"name": "http://packetstormsecurity.com/files/153329/Linux-FreeBSD-TCP-Based-Denial-Of-Service.html",
"url": "http://packetstormsecurity.com/files/153329/Linux-FreeBSD-TCP-Based-Denial-Of-Service.html"
},
{
"refsource": "FREEBSD",
"name": "FreeBSD-SA-19:08",
"url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-19:08.rack.asc"
},
{
"refsource": "CERT-VN",
"name": "VU#905115",
"url": "https://www.kb.cert.org/vuls/id/905115"
},
{
"refsource": "BUGTRAQ",
"name": "20190624 FreeBSD Security Advisory FreeBSD-SA-19:08.rack",
"url": "https://seclists.org/bugtraq/2019/Jun/27"
},
{
"refsource": "MISC",
"name": "http://packetstormsecurity.com/files/153378/FreeBSD-Security-Advisory-FreeBSD-SA-19-08.rack.html",
"url": "http://packetstormsecurity.com/files/153378/FreeBSD-Security-Advisory-FreeBSD-SA-19-08.rack.html"
},
{
"refsource": "MISC",
"name": "https://support.f5.com/csp/article/K75521003",
"url": "https://support.f5.com/csp/article/K75521003"
},
{
"refsource": "MISC",
"name": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44193",
"url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44193"
},
{
"refsource": "MISC",
"name": "https://security.netapp.com/advisory/ntap-20190625-0004/",
"url": "https://security.netapp.com/advisory/ntap-20190625-0004/"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "In FreeBSD 12.0-STABLE before r349197 and 12.0-RELEASE before 12.0-RELEASE-p6, a bug in the non-default RACK TCP stack can allow an attacker to cause several linked lists to grow unbounded and cause an expensive list traversal on every packet being processed, leading to resource exhaustion and a denial of service."
}
]
}

View File

@ -1,17 +1,79 @@
{
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-6620",
"STATE": "RESERVED"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2019-6620",
"ASSIGNER": "f5sirt@f5.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "F5",
"product": {
"product_data": [
{
"product_name": "BIG-IP, BIG-IQ",
"version": {
"version_data": [
{
"version_value": "BIG-IP 14.1.0-14.1.0.5"
},
{
"version_value": "14.0.0-14.0.0.5"
},
{
"version_value": "13.0.0-13.1.1.4"
},
{
"version_value": "12.1.0-12.1.4.1"
},
{
"version_value": "11.5.1-11.6.4"
},
{
"version_value": "BIG-IQ 6.0.0-6.1.0"
},
{
"version_value": "5.1.0-5.4.0"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "privilege escalation"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"name": "https://support.f5.com/csp/article/K20445457",
"url": "https://support.f5.com/csp/article/K20445457"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "On BIG-IP 14.1.0-14.1.0.5, 14.0.0-14.0.0.5, 13.0.0-13.1.1.4, 12.1.0-12.1.4.1, and 11.5.1-11.6.4 and BIG-IQ 6.0.0-6.1.0 and 5.1.0-5.4.0, an undisclosed iControl REST worker vulnerable to command injection for an Administrator user."
}
]
}

View File

@ -1,17 +1,82 @@
{
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-6621",
"STATE": "RESERVED"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2019-6621",
"ASSIGNER": "f5sirt@f5.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "F5",
"product": {
"product_data": [
{
"product_name": "BIG-IP, BIG-IQ",
"version": {
"version_data": [
{
"version_value": "BIG-IP 14.1.0-14.1.0.5"
},
{
"version_value": "14.0.0-14.0.0.4"
},
{
"version_value": "13.0.0-13.1.1.4"
},
{
"version_value": "12.1.0-12.1.4.1"
},
{
"version_value": "11.6.1-11.6.3.4"
},
{
"version_value": "11.5.1-11.5.8"
},
{
"version_value": "BIG-IQ 6.0.0-6.1.0"
},
{
"version_value": "5.1.0-5.4.0"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "privilege escalation"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"name": "https://support.f5.com/csp/article/K20541896",
"url": "https://support.f5.com/csp/article/K20541896"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "On BIG-IP 14.1.0-14.1.0.5, 14.0.0-14.0.0.5, 13.0.0-13.1.1.4, 12.1.0-12.1.4.1, 11.6.1-11.6.3.4, and 11.5.1-11.5.8 and BIG-IQ 6.0.0-6.1.0 and 5.1.0-5.4.0, an undisclosed iControl REST worker is vulnerable to command injection by an admin/resource admin user. This issue impacts both iControl REST and tmsh implementations."
}
]
}

View File

@ -1,17 +1,73 @@
{
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-6622",
"STATE": "RESERVED"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2019-6622",
"ASSIGNER": "f5sirt@f5.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "F5",
"product": {
"product_data": [
{
"product_name": "BIG-IP",
"version": {
"version_data": [
{
"version_value": "BIG-IP 14.1.0-14.1.0.5"
},
{
"version_value": "14.0.0-14.0.0.5"
},
{
"version_value": "13.0.0-13.1.1.4"
},
{
"version_value": "12.1.0-12.1.4.1"
},
{
"version_value": "11.5.1-11.6.4"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "privilege escalation"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"name": "https://support.f5.com/csp/article/K44885536",
"url": "https://support.f5.com/csp/article/K44885536"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "On BIG-IP 14.1.0-14.1.0.5, 14.0.0-14.0.0.5, 13.0.0-13.1.1.4, 12.1.0-12.1.4.1, and 11.5.1-11.6.4, an undisclosed iControl REST worker is vulnerable to command injection by an administrator or resource administrator user. This attack is only exploitable on multi-bladed systems."
}
]
}

View File

@ -1,17 +1,70 @@
{
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-6624",
"STATE": "RESERVED"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2019-6624",
"ASSIGNER": "f5sirt@f5.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "F5",
"product": {
"product_data": [
{
"product_name": "BIG-IP",
"version": {
"version_data": [
{
"version_value": "BIG-IP 14.1.0-14.1.0.5"
},
{
"version_value": "14.0.0-14.0.0.4"
},
{
"version_value": "13.0.0-13.1.1.4"
},
{
"version_value": "12.1.0-12.1.4"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "DoS"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"name": "https://support.f5.com/csp/article/K07127032",