@ -4,14 +4,58 @@
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2021-3643",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ASSIGNER": "secalert@redhat.com",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"vendor_name": "n/a",
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "sox",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "sox 14.4.1"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-125"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://bugzilla.redhat.com/show_bug.cgi?id=1980626",
|
||||
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1980626"
|
||||
}
|
||||
]
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "A flaw was found in sox 14.4.1. The lsx_adpcm_init function within libsox leads to a global-buffer-overflow. This flaw allows an attacker to input a malicious file, leading to the disclosure of sensitive information."
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -4,14 +4,68 @@
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2021-3750",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ASSIGNER": "secalert@redhat.com",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"vendor_name": "n/a",
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "QEMU",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "QEMU before version 7.0.0"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-416"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://bugzilla.redhat.com/show_bug.cgi?id=1999073",
|
||||
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1999073"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://gitlab.com/qemu-project/qemu/-/issues/541",
|
||||
"url": "https://gitlab.com/qemu-project/qemu/-/issues/541"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://gitlab.com/qemu-project/qemu/-/issues/556",
|
||||
"url": "https://gitlab.com/qemu-project/qemu/-/issues/556"
|
||||
}
|
||||
]
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "A DMA reentrancy issue was found in the USB EHCI controller emulation of QEMU. EHCI does not verify if the Buffer Pointer overlaps with its MMIO region when it transfers the USB packets. Crafted content may be written to the controller's registers and trigger undesirable actions (such as reset) while the device is still transferring packets. This can ultimately lead to a use-after-free issue. A malicious guest could use this flaw to crash the QEMU process on the host, resulting in a denial of service condition, or potentially execute arbitrary code within the context of the QEMU process on the host. This flaw affects QEMU versions before 7.0.0."
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,18 +1,104 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
||||
"ID": "CVE-2022-1367",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "DIAEnergie",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "<",
|
||||
"version_value": "1.8.02.004"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "Delta Electronics"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"credit": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Michael Heinzl and Dusan Stevanovic of Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to CISA."
|
||||
}
|
||||
],
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in Handler_TCV.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands."
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 9.8,
|
||||
"baseSeverity": "CRITICAL",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "NONE",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-89 SQL Injection"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01",
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01"
|
||||
}
|
||||
]
|
||||
},
|
||||
"solution": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Delta Electronics has fixed the reported vulnerabilities in Version 1.08.02.004. Users should contact Delta customer service or a Delta representative for this release, as it will not be released publicly. Delta is working on a public release that will include these fixes and other features on June 30, 2022."
|
||||
}
|
||||
],
|
||||
"source": {
|
||||
"advisory": "ICSA-22-081-01",
|
||||
"discovery": "UNKNOWN"
|
||||
},
|
||||
"work_around": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Delta also suggests users:\n\nMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\nLocate control system networks and remote devices behind firewalls and isolate them from the business network.\nUse an application firewall that can detect attacks against \u201cPath Traversal\u201d and \u201cSQL Injection\u201d weakness.\nNever connect programming software to any network other than the network intended for that device.\nWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing a VPN is only as secure as its connected devices"
|
||||
}
|
||||
]
|
||||
}
|
@ -1,18 +1,104 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
||||
"ID": "CVE-2022-1369",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "DIAEnergie",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "<",
|
||||
"version_value": "1.8.02.004"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "Delta Electronics"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"credit": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Michael Heinzl and Dusan Stevanovic of Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to CISA."
|
||||
}
|
||||
],
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in ReadRegIND. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands."
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 9.8,
|
||||
"baseSeverity": "CRITICAL",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "NONE",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-89 SQL Injection"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01",
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01"
|
||||
}
|
||||
]
|
||||
},
|
||||
"solution": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Delta Electronics has fixed the reported vulnerabilities in Version 1.08.02.004. Users should contact Delta customer service or a Delta representative for this release, as it will not be released publicly. Delta is working on a public release that will include these fixes and other features on June 30, 2022."
|
||||
}
|
||||
],
|
||||
"source": {
|
||||
"advisory": "ICSA-22-081-01",
|
||||
"discovery": "UNKNOWN"
|
||||
},
|
||||
"work_around": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Delta also suggests users:\n\nMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\nLocate control system networks and remote devices behind firewalls and isolate them from the business network.\nUse an application firewall that can detect attacks against \u201cPath Traversal\u201d and \u201cSQL Injection\u201d weakness.\nNever connect programming software to any network other than the network intended for that device.\nWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing a VPN is only as secure as its connected devices"
|
||||
}
|
||||
]
|
||||
}
|
@ -1,18 +1,104 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
||||
"ID": "CVE-2022-1370",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "DIAEnergie",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "<",
|
||||
"version_value": "1.8.02.004"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "Delta Electronics"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"credit": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Michael Heinzl and Dusan Stevanovic of Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to CISA."
|
||||
}
|
||||
],
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in ReadREGbyID. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands."
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 9.8,
|
||||
"baseSeverity": "CRITICAL",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "NONE",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-89 SQL Injection"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01",
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01"
|
||||
}
|
||||
]
|
||||
},
|
||||
"solution": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Delta Electronics has fixed the reported vulnerabilities in Version 1.08.02.004. Users should contact Delta customer service or a Delta representative for this release, as it will not be released publicly. Delta is working on a public release that will include these fixes and other features on June 30, 2022."
|
||||
}
|
||||
],
|
||||
"source": {
|
||||
"advisory": "ICSA-22-081-01",
|
||||
"discovery": "UNKNOWN"
|
||||
},
|
||||
"work_around": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Delta also suggests users:\n\nMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\nLocate control system networks and remote devices behind firewalls and isolate them from the business network.\nUse an application firewall that can detect attacks against \u201cPath Traversal\u201d and \u201cSQL Injection\u201d weakness.\nNever connect programming software to any network other than the network intended for that device.\nWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing a VPN is only as secure as its connected devices"
|
||||
}
|
||||
]
|
||||
}
|
@ -1,18 +1,104 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
||||
"ID": "CVE-2022-1371",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "DIAEnergie",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "<",
|
||||
"version_value": "1.8.02.004"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "Delta Electronics"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"credit": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Michael Heinzl and Dusan Stevanovic of Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to CISA."
|
||||
}
|
||||
],
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in ReadRegf. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands."
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 9.8,
|
||||
"baseSeverity": "CRITICAL",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "NONE",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-89 SQL Injection"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01",
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01"
|
||||
}
|
||||
]
|
||||
},
|
||||
"solution": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Delta Electronics has fixed the reported vulnerabilities in Version 1.08.02.004. Users should contact Delta customer service or a Delta representative for this release, as it will not be released publicly. Delta is working on a public release that will include these fixes and other features on June 30, 2022."
|
||||
}
|
||||
],
|
||||
"source": {
|
||||
"advisory": "ICSA-22-081-01",
|
||||
"discovery": "UNKNOWN"
|
||||
},
|
||||
"work_around": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Delta also suggests users:\n\nMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\nLocate control system networks and remote devices behind firewalls and isolate them from the business network.\nUse an application firewall that can detect attacks against \u201cPath Traversal\u201d and \u201cSQL Injection\u201d weakness.\nNever connect programming software to any network other than the network intended for that device.\nWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing a VPN is only as secure as its connected devices"
|
||||
}
|
||||
]
|
||||
}
|
@ -1,18 +1,104 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
||||
"ID": "CVE-2022-1372",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "DIAEnergie",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "<",
|
||||
"version_value": "1.8.02.004"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "Delta Electronics"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"credit": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Michael Heinzl and Dusan Stevanovic of Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to CISA."
|
||||
}
|
||||
],
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in dlSlog.aspx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands."
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 9.8,
|
||||
"baseSeverity": "CRITICAL",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "NONE",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-89 SQL Injection"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01",
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01"
|
||||
}
|
||||
]
|
||||
},
|
||||
"solution": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Delta Electronics has fixed the reported vulnerabilities in Version 1.08.02.004. Users should contact Delta customer service or a Delta representative for this release, as it will not be released publicly. Delta is working on a public release that will include these fixes and other features on June 30, 2022."
|
||||
}
|
||||
],
|
||||
"source": {
|
||||
"advisory": "ICSA-22-081-01",
|
||||
"discovery": "UNKNOWN"
|
||||
},
|
||||
"work_around": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Delta also suggests users:\n\nMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\nLocate control system networks and remote devices behind firewalls and isolate them from the business network.\nUse an application firewall that can detect attacks against \u201cPath Traversal\u201d and \u201cSQL Injection\u201d weakness.\nNever connect programming software to any network other than the network intended for that device.\nWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing a VPN is only as secure as its connected devices"
|
||||
}
|
||||
]
|
||||
}
|
@ -1,18 +1,104 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
||||
"ID": "CVE-2022-1374",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "DIAEnergie",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "<",
|
||||
"version_value": "1.8.02.004"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "Delta Electronics"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"credit": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Michael Heinzl and Dusan Stevanovic of Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to CISA."
|
||||
}
|
||||
],
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_unHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands."
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 9.8,
|
||||
"baseSeverity": "CRITICAL",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "NONE",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-89 SQL Injection"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01",
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01"
|
||||
}
|
||||
]
|
||||
},
|
||||
"solution": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Delta Electronics has fixed the reported vulnerabilities in Version 1.08.02.004. Users should contact Delta customer service or a Delta representative for this release, as it will not be released publicly. Delta is working on a public release that will include these fixes and other features on June 30, 2022."
|
||||
}
|
||||
],
|
||||
"source": {
|
||||
"advisory": "ICSA-22-081-01",
|
||||
"discovery": "UNKNOWN"
|
||||
},
|
||||
"work_around": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Delta also suggests users:\n\nMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\nLocate control system networks and remote devices behind firewalls and isolate them from the business network.\nUse an application firewall that can detect attacks against \u201cPath Traversal\u201d and \u201cSQL Injection\u201d weakness.\nNever connect programming software to any network other than the network intended for that device.\nWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing a VPN is only as secure as its connected devices"
|
||||
}
|
||||
]
|
||||
}
|
@ -1,18 +1,104 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
||||
"ID": "CVE-2022-1375",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "DIAEnergie",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "<",
|
||||
"version_value": "1.8.02.004"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "Delta Electronics"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"credit": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Michael Heinzl and Dusan Stevanovic of Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to CISA."
|
||||
}
|
||||
],
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_slogHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands."
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 9.8,
|
||||
"baseSeverity": "CRITICAL",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "NONE",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-89 SQL Injection"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01",
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01"
|
||||
}
|
||||
]
|
||||
},
|
||||
"solution": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Delta Electronics has fixed the reported vulnerabilities in Version 1.08.02.004. Users should contact Delta customer service or a Delta representative for this release, as it will not be released publicly. Delta is working on a public release that will include these fixes and other features on June 30, 2022."
|
||||
}
|
||||
],
|
||||
"source": {
|
||||
"advisory": "ICSA-22-081-01",
|
||||
"discovery": "UNKNOWN"
|
||||
},
|
||||
"work_around": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Delta also suggests users:\n\nMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\nLocate control system networks and remote devices behind firewalls and isolate them from the business network.\nUse an application firewall that can detect attacks against \u201cPath Traversal\u201d and \u201cSQL Injection\u201d weakness.\nNever connect programming software to any network other than the network intended for that device.\nWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing a VPN is only as secure as its connected devices"
|
||||
}
|
||||
]
|
||||
}
|
@ -1,18 +1,104 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
||||
"ID": "CVE-2022-1376",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "DIAEnergie",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "<",
|
||||
"version_value": "1.8.02.004"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "Delta Electronics"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"credit": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Michael Heinzl and Dusan Stevanovic of Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to CISA."
|
||||
}
|
||||
],
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_privgrpHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands."
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 9.8,
|
||||
"baseSeverity": "CRITICAL",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "NONE",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-89 SQL Injection"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01",
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01"
|
||||
}
|
||||
]
|
||||
},
|
||||
"solution": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Delta Electronics has fixed the reported vulnerabilities in Version 1.08.02.004. Users should contact Delta customer service or a Delta representative for this release, as it will not be released publicly. Delta is working on a public release that will include these fixes and other features on June 30, 2022."
|
||||
}
|
||||
],
|
||||
"source": {
|
||||
"advisory": "ICSA-22-081-01",
|
||||
"discovery": "UNKNOWN"
|
||||
},
|
||||
"work_around": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Delta also suggests users:\n\nMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\nLocate control system networks and remote devices behind firewalls and isolate them from the business network.\nUse an application firewall that can detect attacks against \u201cPath Traversal\u201d and \u201cSQL Injection\u201d weakness.\nNever connect programming software to any network other than the network intended for that device.\nWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing a VPN is only as secure as its connected devices"
|
||||
}
|
||||
]
|
||||
}
|
@ -1,18 +1,104 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
||||
"ID": "CVE-2022-1377",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "DIAEnergie",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "<",
|
||||
"version_value": "1.8.02.004"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "Delta Electronics"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"credit": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Michael Heinzl and Dusan Stevanovic of Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to CISA."
|
||||
}
|
||||
],
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_rltHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands."
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 9.8,
|
||||
"baseSeverity": "CRITICAL",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "NONE",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-89 SQL Injection"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01",
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01"
|
||||
}
|
||||
]
|
||||
},
|
||||
"solution": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Delta Electronics has fixed the reported vulnerabilities in Version 1.08.02.004. Users should contact Delta customer service or a Delta representative for this release, as it will not be released publicly. Delta is working on a public release that will include these fixes and other features on June 30, 2022."
|
||||
}
|
||||
],
|
||||
"source": {
|
||||
"advisory": "ICSA-22-081-01",
|
||||
"discovery": "UNKNOWN"
|
||||
},
|
||||
"work_around": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Delta also suggests users:\n\nMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\nLocate control system networks and remote devices behind firewalls and isolate them from the business network.\nUse an application firewall that can detect attacks against \u201cPath Traversal\u201d and \u201cSQL Injection\u201d weakness.\nNever connect programming software to any network other than the network intended for that device.\nWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing a VPN is only as secure as its connected devices"
|
||||
}
|
||||
]
|
||||
}
|
@ -1,18 +1,104 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "ics-cert@hq.dhs.gov",
|
||||
"ID": "CVE-2022-1378",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "DIAEnergie",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "<",
|
||||
"version_value": "1.8.02.004"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "Delta Electronics"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"credit": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Michael Heinzl and Dusan Stevanovic of Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to CISA."
|
||||
}
|
||||
],
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_pgHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands."
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 9.8,
|
||||
"baseSeverity": "CRITICAL",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "NONE",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-89 SQL Injection"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01",
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01"
|
||||
}
|
||||
]
|
||||
},
|
||||
"solution": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Delta Electronics has fixed the reported vulnerabilities in Version 1.08.02.004. Users should contact Delta customer service or a Delta representative for this release, as it will not be released publicly. Delta is working on a public release that will include these fixes and other features on June 30, 2022."
|
||||
}
|
||||
],
|
||||
"source": {
|
||||
"advisory": "ICSA-22-081-01",
|
||||
"discovery": "UNKNOWN"
|
||||
},
|
||||
"work_around": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Delta also suggests users:\n\nMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\nLocate control system networks and remote devices behind firewalls and isolate them from the business network.\nUse an application firewall that can detect attacks against \u201cPath Traversal\u201d and \u201cSQL Injection\u201d weakness.\nNever connect programming software to any network other than the network intended for that device.\nWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing a VPN is only as secure as its connected devices"
|
||||
}
|
||||
]
|
||||
}
|
@ -4,14 +4,63 @@
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2022-1475",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ASSIGNER": "patrick@puiterwijk.org",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"vendor_name": "n/a",
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "FFmpeg",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "FFmpeg versions before 5.0.1"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-190"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://trac.ffmpeg.org/ticket/9651",
|
||||
"url": "https://trac.ffmpeg.org/ticket/9651"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://bugzilla.redhat.com/show_bug.cgi?id=2076764",
|
||||
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=2076764"
|
||||
}
|
||||
]
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "An integer overflow vulnerability was found in FFmpeg 5.0.1 and in previous versions in g729_parse() in llibavcodec/g729_parser.c when processing a specially crafted file."
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -4,14 +4,63 @@
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2022-1515",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ASSIGNER": "patrick@puiterwijk.org",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"vendor_name": "n/a",
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "matio",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "matio 1.5.22, matio 1.5.23"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-401"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://github.com/tbeu/matio/issues/186",
|
||||
"url": "https://github.com/tbeu/matio/issues/186"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://bugzilla.redhat.com/show_bug.cgi?id=2079986",
|
||||
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=2079986"
|
||||
}
|
||||
]
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "A memory leak was discovered in matio 1.5.21 and earlier in Mat_VarReadNextInfo5() in mat5.c via a crafted file. This issue can potentially result in DoS."
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,18 +1,94 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "security@microfocus.com",
|
||||
"ID": "CVE-2022-26325",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC",
|
||||
"TITLE": "Cross Site Scripting vulnerability in NetIQ Access Manager versions prior to version 5.0.2"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "NetIQ Access Manager",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"platform": "All",
|
||||
"version_affected": "<",
|
||||
"version_name": "NetIQ Access Manager",
|
||||
"version_value": "5.0.2"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "Micro Focus"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Reflected Cross Site Scripting (XSS) vulnerability in NetIQ Access Manager prior to 5.0.2"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "HIGH",
|
||||
"attackVector": "LOCAL",
|
||||
"availabilityImpact": "LOW",
|
||||
"baseScore": 2.9,
|
||||
"baseSeverity": "LOW",
|
||||
"confidentialityImpact": "NONE",
|
||||
"integrityImpact": "LOW",
|
||||
"privilegesRequired": "HIGH",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "REQUIRED",
|
||||
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:N/I:L/A:L",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-79 Cross-site Scripting (XSS)"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"name": "https://www.microfocus.com/documentation/access-manager/5.0/accessmanager502-release-notes/accessmanager502-release-notes.html#t4f2msu33v8h",
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://www.microfocus.com/documentation/access-manager/5.0/accessmanager502-release-notes/accessmanager502-release-notes.html#t4f2msu33v8h"
|
||||
}
|
||||
]
|
||||
},
|
||||
"source": {
|
||||
"discovery": "INTERNAL"
|
||||
},
|
||||
"work_around": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Install / Upgrade NetIQ Access Manager 5.0.2"
|
||||
}
|
||||
]
|
||||
}
|
@ -1,18 +1,94 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "security@microfocus.com",
|
||||
"ID": "CVE-2022-26326",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC",
|
||||
"TITLE": "Potential open redirection vulnerability in NetIQ Access Manager versions prior to version 5.0.2"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "NetIQ Access Manager",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"platform": "All",
|
||||
"version_affected": "<",
|
||||
"version_name": "NetIQ Access Manager",
|
||||
"version_value": "5.0.2"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "Micro Focus"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Potential open redirection vulnerability when URL is crafted in specific format in NetIQ Access Manager prior to 5.0.2"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "HIGH",
|
||||
"attackVector": "LOCAL",
|
||||
"availabilityImpact": "NONE",
|
||||
"baseScore": 4,
|
||||
"baseSeverity": "MEDIUM",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "NONE",
|
||||
"privilegesRequired": "HIGH",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "REQUIRED",
|
||||
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:N/A:N",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-601 URL Redirection to Untrusted Site ('Open Redirect')"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"name": "https://www.microfocus.com/documentation/access-manager/5.0/accessmanager502-release-notes/accessmanager502-release-notes.html#t4f2msu33v8h",
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://www.microfocus.com/documentation/access-manager/5.0/accessmanager502-release-notes/accessmanager502-release-notes.html#t4f2msu33v8h"
|
||||
}
|
||||
]
|
||||
},
|
||||
"source": {
|
||||
"discovery": "EXTERNAL"
|
||||
},
|
||||
"work_around": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Install / Upgrade NetIQ Access Manager 5.0.2"
|
||||
}
|
||||
]
|
||||
}
|
@ -1,18 +1,119 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "cybersecurity@hitachienergy.com",
|
||||
"DATE_PUBLIC": "2022-04-19T10:00:00.000Z",
|
||||
"ID": "CVE-2022-28613",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC",
|
||||
"TITLE": "Specially Crafted Modbus TCP Packet Vulnerability in RTU500 series"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "RTU500 series CMU Firmware",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_name": "12.0.*",
|
||||
"version_value": "12.0.*"
|
||||
},
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_name": "12.2.*",
|
||||
"version_value": "12.2.*"
|
||||
},
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_name": "12.4.*",
|
||||
"version_value": "12.4.*"
|
||||
},
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_name": "12.6.*",
|
||||
"version_value": "12.6.*"
|
||||
},
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_name": "12.7.*",
|
||||
"version_value": "12.7.*"
|
||||
},
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_name": "13.2.*",
|
||||
"version_value": "13.2.*"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "Hitachi Energy"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "A vulnerability in the HCI Modbus TCP COMPONENT of Hitachi Energy RTU500 series CMU Firmware that is caused by the validation error in the length information carried in MBAP header allows an ATTACKER to reboot the device by sending a special crafted message. This issue affects: Hitachi Energy RTU500 series CMU Firmware 12.0.*; 12.2.*; 12.4.*; 12.6.*; 12.7.*; 13.2.*."
|
||||
}
|
||||
]
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 7.5,
|
||||
"baseSeverity": "HIGH",
|
||||
"confidentialityImpact": "NONE",
|
||||
"integrityImpact": "NONE",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "NONE",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-20 Improper Input Validation"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000103&LanguageCode=en&DocumentPartId=&Action=Launch",
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000103&LanguageCode=en&DocumentPartId=&Action=Launch"
|
||||
}
|
||||
]
|
||||
},
|
||||
"solution": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "Remediation available, see the advisory for details."
|
||||
}
|
||||
],
|
||||
"source": {
|
||||
"discovery": "INTERNAL"
|
||||
}
|
||||
}
|
Loading…