"-Synchronized-Data."

This commit is contained in:
CVE Team 2022-11-25 03:00:34 +00:00
parent 23c1463e24
commit 564c2890ba
No known key found for this signature in database
GPG Key ID: E3252B3D49582C98
2 changed files with 524 additions and 136 deletions

View File

@ -1,88 +1,278 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2021-20610",
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric MELSEC iQ-R Series R00/01/02CPU Firmware versions \"24\" and prior, Mitsubishi Electric MELSEC iQ-R Series R04/08/16/32/120(EN)CPU Firmware versions \"57\" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120SFCPU Firmware versions \"28\" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PCPU Firmware versions \"29\" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PSFCPU Firmware versions \"08\" and prior, Mitsubishi Electric MELSEC iQ-R Series R16/32/64MTCPU Operating system software version \"23\" and prior, Mitsubishi Electric MELSEC iQ-R Series R12CCPU-V Firmware versions \"16\" and prior, Mitsubishi Electric MELSEC Q Series Q03UDECPU The first 5 digits of serial No. \"23121\" and prior, Mitsubishi Electric MELSEC Q Series Q04/06/10/13/20/26/50/100UDEHCPU The first 5 digits of serial No. \"23121\" and prior, Mitsubishi Electric MELSEC Q Series Q03/04/06/13/26UDVCPU The first 5 digits of serial No. \"23071\" and prior, Mitsubishi Electric MELSEC Q Series Q04/06/13/26UDPVCPU The first 5 digits of serial No. \"23071\" and prior, Mitsubishi Electric MELSEC Q Series Q12DCCPU-V The first 5 digits of serial No. \"24031\" and prior, Mitsubishi Electric MELSEC Q Series Q24DHCCPU-V(G) The first 5 digits of serial No. \"24031\" and prior, Mitsubishi Electric MELSEC Q Series Q24/26DHCCPU-LS The first 5 digits of serial No. \"24031\" and prior, Mitsubishi Electric MELSEC Q Series MR-MQ100 Operating system software version \"F\" and prior, Mitsubishi Electric MELSEC Q Series Q172/173DCPU-S1 Operating system software version \"W\" and prior, Mitsubishi Electric MELSEC Q Series Q172/173DSCPU All versions, Mitsubishi Electric MELSEC Q Series Q170MCPU Operating system software version \"W\" and prior, Mitsubishi Electric MELSEC Q Series Q170MSCPU(-S1) All versions, Mitsubishi Electric MELSEC L Series L02/06/26CPU(-P) The first 5 digits of serial No. \"23121\" and prior, Mitsubishi Electric MELSEC L Series L26CPU-(P)BT The first 5 digits of serial No. \"23121\" and prior and Mitsubishi Electric MELIPC Series MI5122-VW Firmware versions \"05\" and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending specially crafted packets. System reset is required for recovery."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-130 Improper Handling of Length Parameter Inconsistency",
"cweId": "CWE-130"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"vendor_name": "Mitsubishi Electric",
"product": {
"product_data": [
{
"product_name": "Mitsubishi Electric MELSEC iQ-R Series; Mitsubishi Electric MELSEC Q Series; Mitsubishi Electric MELSEC L Series; Mitsubishi Electric MELIPC Series",
"product_name": "MELSEC iQ-R Series R00/01/02CPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC iQ-R Series R00/01/02CPU Firmware versions \"24\" and prior"
},
"version_value": "Firmware versions \"24\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC iQ-R Series R04/08/16/32/120(EN)CPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC iQ-R Series R04/08/16/32/120(EN)CPU Firmware versions \"57\" and prior"
},
"version_value": "Firmware versions \"57\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC iQ-R Series R08/16/32/120SFCPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120SFCPU All versions"
},
"version_value": "Firmware versions \"28\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC iQ-R Series R08/16/32/120PCPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PCPU Firmware versions \"29\" and prior"
},
"version_value": "Firmware versions \"29\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC iQ-R Series R08/16/32/120PSFCPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PSFCPU Firmware versions \"08\" and prior"
},
"version_value": "Firmware versions \"08\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC iQ-R Series R16/32/64MTCPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC iQ-R Series R16/32/64MTCPU Operating system software version \"23\" and prior"
},
"version_value": "Operating system software version \"23\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC iQ-R Series R12CCPU-V",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC iQ-R Series R12CCPU-V Firmware versions \"16\" and prior"
},
"version_value": "Firmware versions \"16\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q03UDECPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q03UDECPU The first 5 digits of serial No. \"23121\" and prior"
},
"version_value": "The first 5 digits of serial No. \"23121\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q04/06/10/13/20/26/50/100UDEHCPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q04/06/10/13/20/26/50/100UDEHCPU The first 5 digits of serial No. \"23121\" and prior"
},
"version_value": "The first 5 digits of serial No. \"23121\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q03/04/06/13/26UDVCPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q03/04/06/13/26UDVCPU The first 5 digits of serial No. \"23071\" and prior"
},
"version_value": "The first 5 digits of serial No. \"23071\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q04/06/13/26UDPVCPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q04/06/13/26UDPVCPU The first 5 digits of serial No. \"23071\" and prior"
},
"version_value": "The first 5 digits of serial No. \"23071\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q12DCCPU-V",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q12DCCPU-V The first 5 digits of serial No. \"24031\" and prior"
},
"version_value": "The first 5 digits of serial No. \"24031\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q24DHCCPU-V(G)",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q24DHCCPU-V(G) The first 5 digits of serial No. \"24031\" and prior"
},
"version_value": "The first 5 digits of serial No. \"24031\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q24/26DHCCPU-LS",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q24/26DHCCPU-LS The first 5 digits of serial No. \"24031\" and prior"
},
"version_value": "The first 5 digits of serial No. \"24031\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series MR-MQ100",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series MR-MQ100 Operating system software version \"F\" and prior"
},
"version_value": "Operating system software version \"F\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q172/173DCPU-S1",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q172/173DCPU-S1 Operating system software version \"W\" and prior"
},
"version_value": "Operating system software version \"W\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q172/173DSCPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q172/173DSCPU All versions"
},
"version_value": "All versions",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q170MCPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q170MCPU Operating system software version \"W\" and prior"
},
"version_value": "Operating system software version \"W\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q170MSCPU(-S1)",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q170MSCPU(-S1) All versions"
},
"version_value": "All versions",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC L Series L02/06/26CPU(-P)",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC L Series L02/06/26CPU(-P) The first 5 digits of serial No. \"23121\" and prior"
},
"version_value": "The first 5 digits of serial No. \"23121\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC L Series L26CPU-(P)BT",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC L Series L26CPU-(P)BT The first 5 digits of serial No. \"23121\" and prior"
},
"version_value": "The first 5 digits of serial No. \"23121\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELIPC Series MI5122-VW",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELIPC Series MI5122-VW Firmware versions \"05\" and prior"
"version_value": "Firmware versions \"05\" and prior",
"version_affected": "="
}
]
}
@ -93,42 +283,46 @@
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Handling of Length Parameter Inconsistency"
}
]
}
]
},
"references": {
"reference_data": [
{
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-019_en.pdf",
"refsource": "MISC",
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-019_en.pdf",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-019_en.pdf"
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-019_en.pdf"
},
{
"url": "https://jvn.jp/vu/JVNVU94434051/index.html",
"refsource": "MISC",
"name": "https://jvn.jp/vu/JVNVU94434051/index.html",
"url": "https://jvn.jp/vu/JVNVU94434051/index.html"
"name": "https://jvn.jp/vu/JVNVU94434051/index.html"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-334-02",
"refsource": "MISC",
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-334-02",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-334-02"
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-334-02"
}
]
},
"description": {
"description_data": [
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"lang": "eng",
"value": "Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric MELSEC iQ-R Series R00/01/02CPU Firmware versions \"24\" and prior, Mitsubishi Electric MELSEC iQ-R Series R04/08/16/32/120(EN)CPU Firmware versions \"57\" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120SFCPU All versions, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PCPU Firmware versions \"29\" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PSFCPU Firmware versions \"08\" and prior, Mitsubishi Electric MELSEC iQ-R Series R16/32/64MTCPU Operating system software version \"23\" and prior, Mitsubishi Electric MELSEC iQ-R Series R12CCPU-V Firmware versions \"16\" and prior, Mitsubishi Electric MELSEC Q Series Q03UDECPU The first 5 digits of serial No. \"23121\" and prior, Mitsubishi Electric MELSEC Q Series Q04/06/10/13/20/26/50/100UDEHCPU The first 5 digits of serial No. \"23121\" and prior, Mitsubishi Electric MELSEC Q Series Q03/04/06/13/26UDVCPU The first 5 digits of serial No. \"23071\" and prior, Mitsubishi Electric MELSEC Q Series Q04/06/13/26UDPVCPU The first 5 digits of serial No. \"23071\" and prior, Mitsubishi Electric MELSEC Q Series Q12DCCPU-V The first 5 digits of serial No. \"24031\" and prior, Mitsubishi Electric MELSEC Q Series Q24DHCCPU-V(G) The first 5 digits of serial No. \"24031\" and prior, Mitsubishi Electric MELSEC Q Series Q24/26DHCCPU-LS The first 5 digits of serial No. \"24031\" and prior, Mitsubishi Electric MELSEC Q Series MR-MQ100 Operating system software version \"F\" and prior, Mitsubishi Electric MELSEC Q Series Q172/173DCPU-S1 Operating system software version \"W\" and prior, Mitsubishi Electric MELSEC Q Series Q172/173DSCPU All versions, Mitsubishi Electric MELSEC Q Series Q170MCPU Operating system software version \"W\" and prior, Mitsubishi Electric MELSEC Q Series Q170MSCPU(-S1) All versions, Mitsubishi Electric MELSEC L Series L02/06/26CPU(-P) The first 5 digits of serial No. \"23121\" and prior, Mitsubishi Electric MELSEC L Series L26CPU-(P)BT The first 5 digits of serial No. \"23121\" and prior and Mitsubishi Electric MELIPC Series MI5122-VW Firmware versions \"05\" and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending specially crafted packets. System reset is required for recovery."
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
]
}

View File

@ -1,88 +1,278 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2021-20611",
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Input Validation vulnerability in Mitsubishi Electric MELSEC iQ-R Series R00/01/02CPU Firmware versions \"24\" and prior, Mitsubishi Electric MELSEC iQ-R Series R04/08/16/32/120(EN)CPU Firmware versions \"57\" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120SFCPU Firmware versions \"28\" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PCPU Firmware versions \"29\" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PSFCPU Firmware versions \"08\" and prior, Mitsubishi Electric MELSEC iQ-R Series R16/32/64MTCPU Operating system software version \"23\" and prior, Mitsubishi Electric MELSEC iQ-R Series R12CCPU-V Firmware versions \"16\" and prior, Mitsubishi Electric MELSEC Q Series Q03UDECPU The first 5 digits of serial No. \"23121\" and prior, Mitsubishi Electric MELSEC Q Series Q04/06/10/13/20/26/50/100UDEHCPU The first 5 digits of serial No. \"23121\" and prior, Mitsubishi Electric MELSEC Q Series Q03/04/06/13/26UDVCPU The first 5 digits of serial No. \"23071\" and prior, Mitsubishi Electric MELSEC Q Series Q04/06/13/26UDPVCPU The first 5 digits of serial No. \"23071\" and prior, Mitsubishi Electric MELSEC Q Series Q12DCCPU-V The first 5 digits of serial No. \"24031\" and prior, Mitsubishi Electric MELSEC Q Series Q24DHCCPU-V(G) The first 5 digits of serial No. \"24031\" and prior, Mitsubishi Electric MELSEC Q Series Q24/26DHCCPU-LS The first 5 digits of serial No. \"24031\" and prior, Mitsubishi Electric MELSEC Q Series MR-MQ100 Operating system software version \"F\" and prior, Mitsubishi Electric MELSEC Q Series Q172/173DCPU-S1 Operating system software version \"W\" and prior, Mitsubishi Electric MELSEC Q Series Q172/173DSCPU All versions, Mitsubishi Electric MELSEC Q Series Q170MCPU Operating system software version \"W\" and prior, Mitsubishi Electric MELSEC Q Series Q170MSCPU(-S1) All versions, Mitsubishi Electric MELSEC L Series L02/06/26CPU(-P) The first 5 digits of serial No. \"23121\" and prior, Mitsubishi Electric MELSEC L Series L26CPU-(P)BT The first 5 digits of serial No. \"23121\" and prior and Mitsubishi Electric MELIPC Series MI5122-VW Firmware versions \"05\" and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending specially crafted packets. System reset is required for recovery."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20 Improper Input Validation",
"cweId": "CWE-20"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"vendor_name": "Mitsubishi Electric",
"product": {
"product_data": [
{
"product_name": "Mitsubishi Electric MELSEC iQ-R Series; Mitsubishi Electric MELSEC Q Series; Mitsubishi Electric MELSEC L Series; Mitsubishi Electric MELIPC Series",
"product_name": "MELSEC iQ-R Series R00/01/02CPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC iQ-R Series R00/01/02CPU Firmware versions \"24\" and prior"
},
"version_value": "Firmware versions \"24\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC iQ-R Series R04/08/16/32/120(EN)CPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC iQ-R Series R04/08/16/32/120(EN)CPU Firmware versions \"57\" and prior"
},
"version_value": "Firmware versions \"57\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC iQ-R Series R08/16/32/120SFCPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120SFCPU All versions"
},
"version_value": "Firmware versions \"28\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC iQ-R Series R08/16/32/120PCPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PCPU Firmware versions \"29\" and prior"
},
"version_value": "Firmware versions \"29\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC iQ-R Series R08/16/32/120PSFCPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PSFCPU Firmware versions \"08\" and prior"
},
"version_value": "Firmware versions \"08\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC iQ-R Series R16/32/64MTCPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC iQ-R Series R16/32/64MTCPU Operating system software version \"23\" and prior"
},
"version_value": "Operating system software version \"23\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC iQ-R Series R12CCPU-V",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC iQ-R Series R12CCPU-V Firmware versions \"16\" and prior"
},
"version_value": "Firmware versions \"16\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q03UDECPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q03UDECPU The first 5 digits of serial No. \"23121\" and prior"
},
"version_value": "The first 5 digits of serial No. \"23121\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q04/06/10/13/20/26/50/100UDEHCPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q04/06/10/13/20/26/50/100UDEHCPU The first 5 digits of serial No. \"23121\" and prior"
},
"version_value": "The first 5 digits of serial No. \"23121\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q03/04/06/13/26UDVCPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q03/04/06/13/26UDVCPU The first 5 digits of serial No. \"23071\" and prior"
},
"version_value": "The first 5 digits of serial No. \"23071\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q04/06/13/26UDPVCPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q04/06/13/26UDPVCPU The first 5 digits of serial No. \"23071\" and prior"
},
"version_value": "The first 5 digits of serial No. \"23071\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q12DCCPU-V",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q12DCCPU-V The first 5 digits of serial No. \"24031\" and prior"
},
"version_value": "The first 5 digits of serial No. \"24031\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q24DHCCPU-V(G)",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q24DHCCPU-V(G) The first 5 digits of serial No. \"24031\" and prior"
},
"version_value": "The first 5 digits of serial No. \"24031\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q24/26DHCCPU-LS",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q24/26DHCCPU-LS The first 5 digits of serial No. \"24031\" and prior"
},
"version_value": "The first 5 digits of serial No. \"24031\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series MR-MQ100",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series MR-MQ100 Operating system software version \"F\" and prior"
},
"version_value": "Operating system software version \"F\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q172/173DCPU-S1",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q172/173DCPU-S1 Operating system software version \"W\" and prior"
},
"version_value": "Operating system software version \"W\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q172/173DSCPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q172/173DSCPU All versions"
},
"version_value": "All versions",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q170MCPU",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q170MCPU Operating system software version \"W\" and prior"
},
"version_value": "Operating system software version \"W\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC Q Series Q170MSCPU(-S1)",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC Q Series Q170MSCPU(-S1) All versions"
},
"version_value": "All versions",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC L Series L02/06/26CPU(-P)",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC L Series L02/06/26CPU(-P) The first 5 digits of serial No. \"23121\" and prior"
},
"version_value": "The first 5 digits of serial No. \"23121\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELSEC L Series L26CPU-(P)BT",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELSEC L Series L26CPU-(P)BT The first 5 digits of serial No. \"23121\" and prior"
},
"version_value": "The first 5 digits of serial No. \"23121\" and prior",
"version_affected": "="
}
]
}
},
{
"product_name": "MELIPC Series MI5122-VW",
"version": {
"version_data": [
{
"version_value": "Mitsubishi Electric MELIPC Series MI5122-VW Firmware versions \"05\" and prior"
"version_value": "Firmware versions \"05\" and prior",
"version_affected": "="
}
]
}
@ -93,42 +283,46 @@
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Input Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-019_en.pdf",
"refsource": "MISC",
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-019_en.pdf",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-019_en.pdf"
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-019_en.pdf"
},
{
"url": "https://jvn.jp/vu/JVNVU94434051/index.html",
"refsource": "MISC",
"name": "https://jvn.jp/vu/JVNVU94434051/index.html",
"url": "https://jvn.jp/vu/JVNVU94434051/index.html"
"name": "https://jvn.jp/vu/JVNVU94434051/index.html"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-334-02",
"refsource": "MISC",
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-334-02",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-334-02"
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-334-02"
}
]
},
"description": {
"description_data": [
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"lang": "eng",
"value": "Improper Input Validation vulnerability in Mitsubishi Electric MELSEC iQ-R Series R00/01/02CPU Firmware versions \"24\" and prior, Mitsubishi Electric MELSEC iQ-R Series R04/08/16/32/120(EN)CPU Firmware versions \"57\" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120SFCPU All versions, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PCPU Firmware versions \"29\" and prior, Mitsubishi Electric MELSEC iQ-R Series R08/16/32/120PSFCPU Firmware versions \"08\" and prior, Mitsubishi Electric MELSEC iQ-R Series R16/32/64MTCPU Operating system software version \"23\" and prior, Mitsubishi Electric MELSEC iQ-R Series R12CCPU-V Firmware versions \"16\" and prior, Mitsubishi Electric MELSEC Q Series Q03UDECPU The first 5 digits of serial No. \"23121\" and prior, Mitsubishi Electric MELSEC Q Series Q04/06/10/13/20/26/50/100UDEHCPU The first 5 digits of serial No. \"23121\" and prior, Mitsubishi Electric MELSEC Q Series Q03/04/06/13/26UDVCPU The first 5 digits of serial No. \"23071\" and prior, Mitsubishi Electric MELSEC Q Series Q04/06/13/26UDPVCPU The first 5 digits of serial No. \"23071\" and prior, Mitsubishi Electric MELSEC Q Series Q12DCCPU-V The first 5 digits of serial No. \"24031\" and prior, Mitsubishi Electric MELSEC Q Series Q24DHCCPU-V(G) The first 5 digits of serial No. \"24031\" and prior, Mitsubishi Electric MELSEC Q Series Q24/26DHCCPU-LS The first 5 digits of serial No. \"24031\" and prior, Mitsubishi Electric MELSEC Q Series MR-MQ100 Operating system software version \"F\" and prior, Mitsubishi Electric MELSEC Q Series Q172/173DCPU-S1 Operating system software version \"W\" and prior, Mitsubishi Electric MELSEC Q Series Q172/173DSCPU All versions, Mitsubishi Electric MELSEC Q Series Q170MCPU Operating system software version \"W\" and prior, Mitsubishi Electric MELSEC Q Series Q170MSCPU(-S1) All versions, Mitsubishi Electric MELSEC L Series L02/06/26CPU(-P) The first 5 digits of serial No. \"23121\" and prior, Mitsubishi Electric MELSEC L Series L26CPU-(P)BT The first 5 digits of serial No. \"23121\" and prior and Mitsubishi Electric MELIPC Series MI5122-VW Firmware versions \"05\" and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending specially crafted packets. System reset is required for recovery."
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
]
}