"-Synchronized-Data."

This commit is contained in:
CVE Team 2023-09-20 01:00:34 +00:00
parent a37ca4bc63
commit 5824958fbe
No known key found for this signature in database
GPG Key ID: E3252B3D49582C98
15 changed files with 1053 additions and 66 deletions

View File

@ -1,17 +1,87 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-25525",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "psirt@nvidia.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "NVIDIA Cumulus Linux contains a vulnerability in forwarding where a VxLAN-encapsulated IPv6 packet received on an SVI interface with DMAC/DIPv6 set to the link-local address of the SVI interface may be incorrectly forwarded. A successful exploit may lead to information disclosure."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284",
"cweId": "CWE-284"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "NVIDIA",
"product": {
"product_data": [
{
"product_name": "Cumulus Linux",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions prior to 5.6.0"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://nvidia.custhelp.com/app/answers/detail/a_id/5480",
"refsource": "MISC",
"name": "https://nvidia.custhelp.com/app/answers/detail/a_id/5480"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,87 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-25526",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "psirt@nvidia.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "NVIDIA Cumulus Linux contains a vulnerability in neighmgrd and nlmanager where an attacker on an adjacent network may cause an uncaught exception by injecting a crafted packet. A successful exploit may lead to denial of service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248",
"cweId": "CWE-248"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "NVIDIA",
"product": {
"product_data": [
{
"product_name": "Cumulus Linux",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions prior to 5.5.0"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://nvidia.custhelp.com/app/answers/detail/a_id/5480",
"refsource": "MISC",
"name": "https://nvidia.custhelp.com/app/answers/detail/a_id/5480"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,87 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-25527",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "psirt@nvidia.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "NVIDIA DGX H100 BMC contains a vulnerability in the host KVM daemon, where an authenticated local attacker may cause corruption of kernel memory. A successful exploit of this vulnerability may lead to arbitrary kernel code execution, denial of service, escalation of privileges, information disclosure, and data tampering."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
"cweId": "CWE-119"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "NVIDIA",
"product": {
"product_data": [
{
"product_name": "DGX H100 BMC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions prior to 23.08.07"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://nvidia.custhelp.com/app/answers/detail/a_id/5473",
"refsource": "MISC",
"name": "https://nvidia.custhelp.com/app/answers/detail/a_id/5473"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,87 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-25528",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "psirt@nvidia.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "NVIDIA DGX H100 baseboard management controller (BMC) contains a vulnerability in a web server plugin, where an unauthenticated attacker may cause a stack overflow by sending a specially crafted network packet. A successful exploit of this vulnerability may lead to arbitrary code execution, denial of service, information disclosure, and data tampering."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121: Stack-based Buffer Overflow",
"cweId": "CWE-121"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "NVIDIA",
"product": {
"product_data": [
{
"product_name": "DGX H100 BMC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions prior to 23.08.07"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://nvidia.custhelp.com/app/answers/detail/a_id/5473",
"refsource": "MISC",
"name": "https://nvidia.custhelp.com/app/answers/detail/a_id/5473"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,87 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-25529",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "psirt@nvidia.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "NVIDIA DGX H100 BMC contains a vulnerability in the host KVM daemon, where an unauthenticated attacker may cause a leak of another user\u2019s session token by observing timing discrepancies between server responses. A successful exploit of this vulnerability may lead to information disclosure, escalation of privileges, and data tampering."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-208",
"cweId": "CWE-208"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "NVIDIA",
"product": {
"product_data": [
{
"product_name": "DGX H100 BMC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions prior to 23.08.07"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://nvidia.custhelp.com/app/answers/detail/a_id/5473",
"refsource": "MISC",
"name": "https://nvidia.custhelp.com/app/answers/detail/a_id/5473"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:N",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,87 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-25530",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "psirt@nvidia.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "NVIDIA DGX H100 BMC contains a vulnerability in the KVM service, where an attacker may cause improper input validation. A successful exploit of this vulnerability may lead to code execution, denial of service, escalation of privileges, and information disclosure."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20 Improper Input Validation",
"cweId": "CWE-20"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "NVIDIA",
"product": {
"product_data": [
{
"product_name": "DGX H100 BMC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions prior to 23.08.07"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://nvidia.custhelp.com/app/answers/detail/a_id/5473",
"refsource": "MISC",
"name": "https://nvidia.custhelp.com/app/answers/detail/a_id/5473"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,87 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-25531",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "psirt@nvidia.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "NVIDIA DGX H100 BMC contains a vulnerability in IPMI, where an attacker may cause insufficient protection of credentials. A successful exploit of this vulnerability may lead to code execution, denial of service, information disclosure, and escalation of privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-522 Insufficiently Protected Credentials",
"cweId": "CWE-522"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "NVIDIA",
"product": {
"product_data": [
{
"product_name": "DGX H100 BMC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions prior to 23.08.07"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://nvidia.custhelp.com/app/answers/detail/a_id/5473",
"refsource": "MISC",
"name": "https://nvidia.custhelp.com/app/answers/detail/a_id/5473"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,87 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-25532",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "psirt@nvidia.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "NVIDIA DGX H100 BMC contains a vulnerability in IPMI, where an attacker may cause insufficient protection of credentials. A successful exploit of this vulnerability may lead to information disclosure."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-522 Insufficiently Protected Credentials",
"cweId": "CWE-522"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "NVIDIA",
"product": {
"product_data": [
{
"product_name": "DGX H100 BMC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions prior to 23.08.07"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://nvidia.custhelp.com/app/answers/detail/a_id/5473",
"refsource": "MISC",
"name": "https://nvidia.custhelp.com/app/answers/detail/a_id/5473"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,87 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-25533",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "psirt@nvidia.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "NVIDIA DGX H100 BMC contains a vulnerability in the web UI, where an attacker may cause improper input validation. A successful exploit of this vulnerability may lead to information disclosure, code execution, and escalation of privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20 Improper Input Validation",
"cweId": "CWE-20"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "NVIDIA",
"product": {
"product_data": [
{
"product_name": "DGX H100 BMC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions prior to 23.08.07"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://nvidia.custhelp.com/app/answers/detail/a_id/5473",
"refsource": "MISC",
"name": "https://nvidia.custhelp.com/app/answers/detail/a_id/5473"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:L",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,87 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-25534",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "psirt@nvidia.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "NVIDIA DGX H100 BMC contains a vulnerability in IPMI, where an attacker may cause improper input validation. A successful exploit of this vulnerability may lead to code execution, denial of service, escalation of privileges, information disclosure, and data tampering."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20 Improper Input Validation",
"cweId": "CWE-20"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "NVIDIA",
"product": {
"product_data": [
{
"product_name": "DGX H100 BMC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions prior to 23.08.07"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://nvidia.custhelp.com/app/answers/detail/a_id/5473",
"refsource": "MISC",
"name": "https://nvidia.custhelp.com/app/answers/detail/a_id/5473"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:H",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,87 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-31008",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "psirt@nvidia.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "NVIDIA DGX H100 BMC contains a vulnerability in IPMI, where an attacker may cause improper input validation. A successful exploit of this vulnerability may lead to code execution, denial of services, escalation of privileges, and information disclosure."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20 Improper Input Validation",
"cweId": "CWE-20"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "NVIDIA",
"product": {
"product_data": [
{
"product_name": "DGX H100 BMC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions prior to 23.08.07"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://nvidia.custhelp.com/app/answers/detail/a_id/5473",
"refsource": "MISC",
"name": "https://nvidia.custhelp.com/app/answers/detail/a_id/5473"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:H",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,87 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-31009",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "psirt@nvidia.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "NVIDIA DGX H100 BMC contains a vulnerability in the REST service, where an attacker may cause improper input validation. A successful exploit of this vulnerability may lead to code execution, denial of service, escalation of privileges, and information disclosure."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20 Improper Input Validation",
"cweId": "CWE-20"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "NVIDIA",
"product": {
"product_data": [
{
"product_name": "DGX H100 BMC",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions prior to 23.08.07"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://nvidia.custhelp.com/app/answers/detail/a_id/5473",
"refsource": "MISC",
"name": "https://nvidia.custhelp.com/app/answers/detail/a_id/5473"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
"version": "3.1"
}
]
}

View File

@ -1,17 +1,66 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38886",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ID": "CVE-2023-38886",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "An issue in Dolibarr ERP CRM v.17.0.1 and before allows a remote privileged attacker to execute arbitrary code via a crafted command/script."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"url": "http://dolibarr.com",
"refsource": "MISC",
"name": "http://dolibarr.com"
},
{
"refsource": "MISC",
"name": "https://akerva.com/wp-content/uploads/2023/09/AKERVA_Security-Advisory_CVE-2023-38886_Dolibarr_RCE-1.pdf",
"url": "https://akerva.com/wp-content/uploads/2023/09/AKERVA_Security-Advisory_CVE-2023-38886_Dolibarr_RCE-1.pdf"
}
]
}

View File

@ -1,17 +1,66 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38887",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ID": "CVE-2023-38887",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "File Upload vulnerability in Dolibarr ERP CRM v.17.0.1 and before allows a remote attacker to execute arbitrary code and obtain sensitive information via the extension filtering and renaming functions."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"url": "http://dolibarr.com",
"refsource": "MISC",
"name": "http://dolibarr.com"
},
{
"refsource": "MISC",
"name": "https://akerva.com/wp-content/uploads/2023/09/AKERVA_Security-Advisory_CVE-2023-38887_Dolibarr_AFU.pdf",
"url": "https://akerva.com/wp-content/uploads/2023/09/AKERVA_Security-Advisory_CVE-2023-38887_Dolibarr_AFU.pdf"
}
]
}

View File

@ -1,17 +1,66 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38888",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ID": "CVE-2023-38888",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Cross Site Scripting vulnerability in Dolibarr ERP CRM v.17.0.1 and before allows a remote attacker to obtain sensitive information and execute arbitrary code via the REST API module, related to analyseVarsForSqlAndScriptsInjection and testSqlAndScriptInject."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"url": "http://dolibarr.com",
"refsource": "MISC",
"name": "http://dolibarr.com"
},
{
"refsource": "MISC",
"name": "https://akerva.com/wp-content/uploads/2023/09/AKERVA_Security-Advisory_CVE-2023-38888_Dolibarr_XSS.pdf",
"url": "https://akerva.com/wp-content/uploads/2023/09/AKERVA_Security-Advisory_CVE-2023-38888_Dolibarr_XSS.pdf"
}
]
}