- Added submission from Schneider Electric from 2018-03-09.

This commit is contained in:
CVE Team 2018-03-09 17:06:08 -05:00
parent c8cf8523be
commit 6638f20c11
No known key found for this signature in database
GPG Key ID: 3504EC0FB4B2FE56
13 changed files with 598 additions and 39 deletions

View File

@ -1,8 +1,32 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "cybersecurity@schneider-electric.com",
"DATE_PUBLIC" : "2018-03-01T00:00:00",
"ID" : "CVE-2018-7227",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "Pelco Sarix Professional",
"version" : {
"version_data" : [
{
"version_value" : "all firmware versions prior to 3.29.67"
}
]
}
}
]
},
"vendor_name" : "Schneider Electric SE"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +35,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow retrieving of specially crafted URLs without authentication that can reveal sensitive information to an attacker."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "Information Disclosure"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01/"
}
]
}

View File

@ -1,8 +1,32 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "cybersecurity@schneider-electric.com",
"DATE_PUBLIC" : "2018-03-01T00:00:00",
"ID" : "CVE-2018-7228",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "Pelco Sarix Professional",
"version" : {
"version_data" : [
{
"version_value" : "all firmware versions prior to 3.29.68"
}
]
}
}
]
},
"vendor_name" : "Schneider Electric SE"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +35,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and get the administrator privileges."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "Authentication Bypass"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01/"
}
]
}

View File

@ -1,8 +1,32 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "cybersecurity@schneider-electric.com",
"DATE_PUBLIC" : "2018-03-01T00:00:00",
"ID" : "CVE-2018-7229",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "Pelco Sarix Professional",
"version" : {
"version_data" : [
{
"version_value" : "all firmware versions prior to 3.29.69"
}
]
}
}
]
},
"vendor_name" : "Schneider Electric SE"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +35,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could alllow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hard carded credentials."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "Authentication Bypass"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01/"
}
]
}

View File

@ -1,8 +1,32 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "cybersecurity@schneider-electric.com",
"DATE_PUBLIC" : "2018-03-01T00:00:00",
"ID" : "CVE-2018-7230",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "Pelco Sarix Professional",
"version" : {
"version_data" : [
{
"version_value" : "all firmware versions prior to 3.29.70"
}
]
}
}
]
},
"vendor_name" : "Schneider Electric SE"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +35,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A XML external entity (XXE) vulnerability exists in the import.cgi of the web interface component of the Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "XML External Entity Processing"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01/"
}
]
}

View File

@ -1,8 +1,32 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "cybersecurity@schneider-electric.com",
"DATE_PUBLIC" : "2018-03-01T00:00:00",
"ID" : "CVE-2018-7231",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "Pelco Sarix Professional",
"version" : {
"version_data" : [
{
"version_value" : "all firmware versions prior to 3.29.71"
}
]
}
}
]
},
"vendor_name" : "Schneider Electric SE"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +35,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'system.opkg.remove'."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "Command Execution"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01/"
}
]
}

View File

@ -1,8 +1,32 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "cybersecurity@schneider-electric.com",
"DATE_PUBLIC" : "2018-03-01T00:00:00",
"ID" : "CVE-2018-7232",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "Pelco Sarix Professional",
"version" : {
"version_data" : [
{
"version_value" : "all firmware versions prior to 3.29.72"
}
]
}
}
]
},
"vendor_name" : "Schneider Electric SE"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +35,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'network.ieee8021x.delete_certs'."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "Command Execution"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01/"
}
]
}

View File

@ -1,8 +1,32 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "cybersecurity@schneider-electric.com",
"DATE_PUBLIC" : "2018-03-01T00:00:00",
"ID" : "CVE-2018-7233",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "Pelco Sarix Professional",
"version" : {
"version_data" : [
{
"version_value" : "all firmware versions prior to 3.29.73"
}
]
}
}
]
},
"vendor_name" : "Schneider Electric SE"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +35,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'model_name'or 'mac_address'."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "Command Execution"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01/"
}
]
}

View File

@ -1,8 +1,32 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "cybersecurity@schneider-electric.com",
"DATE_PUBLIC" : "2018-03-01T00:00:00",
"ID" : "CVE-2018-7234",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "Pelco Sarix Professional",
"version" : {
"version_data" : [
{
"version_value" : "all firmware versions prior to 3.29.74"
}
]
}
}
]
},
"vendor_name" : "Schneider Electric SE"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +35,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of SSL certificate."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "Arbitrary File Download"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01/"
}
]
}

View File

@ -1,8 +1,32 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "cybersecurity@schneider-electric.com",
"DATE_PUBLIC" : "2018-03-01T00:00:00",
"ID" : "CVE-2018-7235",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "Pelco Sarix Professional",
"version" : {
"version_data" : [
{
"version_value" : "all firmware versions prior to 3.29.75"
}
]
}
}
]
},
"vendor_name" : "Schneider Electric SE"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +35,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of the shell meta characters with the value of 'system.download.sd_file'"
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "Command Execution"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01/"
}
]
}

View File

@ -1,8 +1,32 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "cybersecurity@schneider-electric.com",
"DATE_PUBLIC" : "2018-03-01T00:00:00",
"ID" : "CVE-2018-7236",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "Pelco Sarix Professional",
"version" : {
"version_data" : [
{
"version_value" : "all firmware versions prior to 3.29.76"
}
]
}
}
]
},
"vendor_name" : "Schneider Electric SE"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +35,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could enable SSH service due to lack of authentication for /login/bin/set_param could enable SSH service."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "Authentication Bypass"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01/"
}
]
}

View File

@ -1,8 +1,32 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "cybersecurity@schneider-electric.com",
"DATE_PUBLIC" : "2018-03-01T00:00:00",
"ID" : "CVE-2018-7237",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "Pelco Sarix Professional",
"version" : {
"version_data" : [
{
"version_value" : "all firmware versions prior to 3.29.77"
}
]
}
}
]
},
"vendor_name" : "Schneider Electric SE"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +35,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow a remote attacker to delete arbitrary system file due to lack of validation of the /login/bin/set_param to the file name with the value of 'system.delete.sd_file'"
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "Arbitrary File Delete"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01/"
}
]
}

View File

@ -1,8 +1,32 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "cybersecurity@schneider-electric.com",
"DATE_PUBLIC" : "2018-03-01T00:00:00",
"ID" : "CVE-2018-7238",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "Pelco Sarix Professional",
"version" : {
"version_data" : [
{
"version_value" : "all firmware versions prior to 3.29.78"
}
]
}
}
]
},
"vendor_name" : "Schneider Electric SE"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +35,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to execute arbitrary code."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "Buffer Overflow"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://www.schneider-electric.com/en/download/document/SEVD-2018-058-01/"
}
]
}

View File

@ -1,8 +1,32 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "cybersecurity@schneider-electric.com",
"DATE_PUBLIC" : "2018-03-01T00:00:00",
"ID" : "CVE-2018-7239",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "SoMove",
"version" : {
"version_data" : [
{
"version_value" : "n/a"
}
]
}
}
]
},
"vendor_name" : "Schneider Electric SE"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +35,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "A dll hijacking vulnerability exisits in Schneider Electric's SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "DLL Hijacking"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/"
}
]
}