mirror of
https://github.com/CVEProject/cvelist.git
synced 2025-06-12 02:05:39 +00:00
"Update to CVE-2021-22783"
This commit is contained in:
parent
98adb7d551
commit
6bb9f31019
@ -1,18 +1,83 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "cybersecurity@se.com",
|
||||
"ID": "CVE-2021-22783",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "Ritto Wiser Door",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "All versions "
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "Schneider Electric"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "A CWE-200: Information Exposure vulnerability exists which could allow a session hijack when the door panel is communicating with the door. Affected Product: Ritto Wiser Door (All versions)"
|
||||
}
|
||||
]
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "LOW",
|
||||
"attackVector": "ADJACENT_NETWORK",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 8.8,
|
||||
"baseSeverity": "HIGH",
|
||||
"confidentialityImpact": "HIGH",
|
||||
"integrityImpact": "HIGH",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "NONE",
|
||||
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-200 Information Exposure"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-03"
|
||||
}
|
||||
]
|
||||
},
|
||||
"source": {
|
||||
"discovery": "UNKNOWN"
|
||||
}
|
||||
}
|
@ -1,18 +1,84 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "cybersecurity@se.com",
|
||||
"ID": "CVE-2022-24322",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "EcoStruxure Control Expert",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_name": "V15.0 SP1",
|
||||
"version_value": "and prior"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "Schneider Electric"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)"
|
||||
}
|
||||
]
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "HIGH",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 5.3,
|
||||
"baseSeverity": "MEDIUM",
|
||||
"confidentialityImpact": "NONE",
|
||||
"integrityImpact": "NONE",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "REQUIRED",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01"
|
||||
}
|
||||
]
|
||||
},
|
||||
"source": {
|
||||
"discovery": "UNKNOWN"
|
||||
}
|
||||
}
|
@ -1,18 +1,95 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "cybersecurity@se.com",
|
||||
"ID": "CVE-2022-24323",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "EcoStruxure Process Expert",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_name": "V2021",
|
||||
"version_value": "and prior"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "EcoStruxure Control Expert",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_name": "V15.0 SP1",
|
||||
"version_value": "and prior"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "Schneider Electric"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Process Expert (V2021 and prior), EcoStruxure Control Expert (V15.0 SP1 and prior)"
|
||||
}
|
||||
]
|
||||
},
|
||||
"generator": {
|
||||
"engine": "Vulnogram 0.0.9"
|
||||
},
|
||||
"impact": {
|
||||
"cvss": {
|
||||
"attackComplexity": "HIGH",
|
||||
"attackVector": "NETWORK",
|
||||
"availabilityImpact": "HIGH",
|
||||
"baseScore": 5.3,
|
||||
"baseSeverity": "MEDIUM",
|
||||
"confidentialityImpact": "NONE",
|
||||
"integrityImpact": "NONE",
|
||||
"privilegesRequired": "NONE",
|
||||
"scope": "UNCHANGED",
|
||||
"userInteraction": "REQUIRED",
|
||||
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H",
|
||||
"version": "3.1"
|
||||
}
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-754 Improper Check for Unusual or Exceptional Conditions"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-067-01"
|
||||
}
|
||||
]
|
||||
},
|
||||
"source": {
|
||||
"discovery": "UNKNOWN"
|
||||
}
|
||||
}
|
Loading…
x
Reference in New Issue
Block a user