"-Synchronized-Data."

This commit is contained in:
CVE Team 2020-06-25 20:01:17 +00:00
parent f82f04adb4
commit 7998cd4b7c
No known key found for this signature in database
GPG Key ID: 5708902F06FEF743
6 changed files with 285 additions and 19 deletions

View File

@ -0,0 +1,62 @@
{
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-16213",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 could allow a remote authenticated attacker to execute arbitrary commands on the system. By sending a specially crafted string, an attacker could modify the device name of an attached PLC adapter to inject and execute arbitrary commands on the system with root privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://securityintelligence.com/posts/vulnerable-powerline-extenders-underline-lax-iot-security/",
"url": "https://securityintelligence.com/posts/vulnerable-powerline-extenders-underline-lax-iot-security/"
}
]
}
}

View File

@ -1,17 +1,61 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2019-19505",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ID": "CVE-2019-19505",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 is vulnerable to a stack-based buffer overflow, caused by improper bounds checking by the \"Wireless\" section in the web-UI. By sending a specially crafted hostname, a remote attacker could overflow a buffer and execute arbitrary code on the system or cause the application to crash."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://securityintelligence.com/posts/vulnerable-powerline-extenders-underline-lax-iot-security/",
"url": "https://securityintelligence.com/posts/vulnerable-powerline-extenders-underline-lax-iot-security/"
}
]
}

View File

@ -1,17 +1,61 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2019-19506",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ID": "CVE-2019-19506",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 is vulnerable to a denial of service, caused by an error in the \"homeplugd\" process. By sending a specially crafted UDP packet, an attacker could exploit this vulnerability to cause the device to reboot."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://securityintelligence.com/posts/vulnerable-powerline-extenders-underline-lax-iot-security/",
"url": "https://securityintelligence.com/posts/vulnerable-powerline-extenders-underline-lax-iot-security/"
}
]
}

View File

@ -34,7 +34,7 @@
"description_data": [
{
"lang": "eng",
"value": "** DISPUTED ** An issue was discovered in Halvotec RaQuest 10.23.10801.0. It allows session fixation. NOTE: the vendor does not recognize this issue and will not patch it."
"value": "An issue was discovered in Halvotec RaQuest 10.23.10801.0. It allows session fixation. Fixed in Release 24.2020.20608.0."
}
]
},

View File

@ -0,0 +1,62 @@
{
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-15302",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In Argent RecoveryManager before 0xdc350d09f71c48c5D22fBE2741e4d6A03970E192, the executeRecovery function does not require any signatures in the zero-guardian case, which allows attackers to cause a denial of service (locking) or a takeover."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"url": "https://blog.openzeppelin.com/argent-vulnerability-report/",
"refsource": "MISC",
"name": "https://blog.openzeppelin.com/argent-vulnerability-report/"
}
]
}
}

View File

@ -1,17 +1,71 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-9437",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ID": "CVE-2020-9437",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "SecureAuth.aspx in SecureAuth IdP 9.3.0 suffers from a client-side template injection that allows for script execution, in the same manner as XSS."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"url": "https://know.bishopfox.com/advisories",
"refsource": "MISC",
"name": "https://know.bishopfox.com/advisories"
},
{
"url": "https://docs.secureauth.com/display/SID/SecureAuth+IdP+Latest+Releases",
"refsource": "MISC",
"name": "https://docs.secureauth.com/display/SID/SecureAuth+IdP+Latest+Releases"
},
{
"refsource": "MISC",
"name": "https://labs.bishopfox.com/advisories/secureauth-version-9.3",
"url": "https://labs.bishopfox.com/advisories/secureauth-version-9.3"
}
]
}