"-Synchronized-Data."

This commit is contained in:
CVE Team 2023-06-29 08:00:36 +00:00
parent 12677d6119
commit 8210977e6d
No known key found for this signature in database
GPG Key ID: E3252B3D49582C98
4 changed files with 10 additions and 10 deletions

View File

@ -11,7 +11,7 @@
"description_data": [
{
"lang": "eng",
"value": "Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 all versions and Mitsubishi Electric MX OPC UA Module Configurator-R all versions allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module."
"value": "Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module."
}
]
},
@ -41,7 +41,7 @@
"version_data": [
{
"version_affected": "=",
"version_value": "all versions"
"version_value": "from 1.000A to 1.095Z"
}
]
}
@ -52,7 +52,7 @@
"version_data": [
{
"version_affected": "=",
"version_value": "all versions"
"version_value": "1.08J and prior"
}
]
}

View File

@ -11,7 +11,7 @@
"description_data": [
{
"lang": "eng",
"value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 all versions allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally."
"value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project files or execute programs illegally."
}
]
},
@ -41,7 +41,7 @@
"version_data": [
{
"version_affected": "=",
"version_value": "all versions"
"version_value": "from 1.000A and later"
}
]
}

View File

@ -11,7 +11,7 @@
"description_data": [
{
"lang": "eng",
"value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 all versions allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project file or execute programs illegally."
"value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project file or execute programs illegally."
}
]
},
@ -41,7 +41,7 @@
"version_data": [
{
"version_affected": "=",
"version_value": "all versions"
"version_value": "from 1.000A and later"
}
]
}

View File

@ -11,7 +11,7 @@
"description_data": [
{
"lang": "eng",
"value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 all versions and Motion Control Setting(GX Works3 related software) all versions allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated users may obtain information about project files illegally."
"value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally."
}
]
},
@ -41,7 +41,7 @@
"version_data": [
{
"version_affected": "=",
"version_value": "all versions"
"version_value": "from 1.000A to 1.095Z"
}
]
}
@ -52,7 +52,7 @@
"version_data": [
{
"version_affected": "=",
"version_value": "all versions"
"version_value": "from 1.000A and later"
}
]
}