Siemens CVE update for Siemens-AD-2020-04

This commit is contained in:
Thomas Kittel 2020-04-14 14:50:43 +02:00
parent 6d9ab4eaa1
commit 838939cc7c
9 changed files with 605 additions and 80 deletions

View File

@ -29,7 +29,7 @@
"version": {
"version_data": [
{
"version_value": "All versions < V15.1 Upd 4"
"version_value": "All versions < V15.1 Update 4"
}
]
}
@ -39,7 +39,7 @@
"version": {
"version_data": [
{
"version_value": "All versions"
"version_value": "All versions < V16 Update 1"
}
]
}
@ -66,7 +66,7 @@
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Upd 4), TIA Portal V16 (All versions). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known."
"value": "A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 4), TIA Portal V16 (All versions < V16 Update 1). Changing the contents of a configuration file could allow an attacker to\nexecute arbitrary code with SYSTEM privileges.\n\nThe security vulnerability could be exploited by an attacker with a valid\naccount and limited access rights on the system. No user interaction is\nrequired.\n\nAt the time of advisory publication no public exploitation of this security\nvulnerability was known. \n"
}
]
},

View File

@ -74,16 +74,6 @@
]
}
},
{
"product_name": "SIMATIC ET200AL (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET200M (incl. SIPLUS variants)",
"version": {
@ -109,7 +99,7 @@
"version": {
"version_data": [
{
"version_value": "All versions"
"version_value": "All versions < V4.4.0"
}
]
}
@ -204,16 +194,6 @@
]
}
},
{
"product_name": "SIMATIC ET200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions < V2.0"
}
]
}
},
{
"product_name": "SIMATIC ET200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0)",
"version": {
@ -234,16 +214,6 @@
]
}
},
{
"product_name": "SIMATIC ET200pro (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (incl. SIPLUS variants)",
"version": {
@ -274,16 +244,6 @@
]
}
},
{
"product_name": "SIMATIC HMI KTP Mobile Panels (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
"version": {
@ -576,7 +536,7 @@
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC CFU PA, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET200AL, SIMATIC ET200AL (incl. SIPLUS variants), SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC ET200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0), SIMATIC ET200pro, SIMATIC ET200pro (incl. SIPLUS variants), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (incl. SIPLUS variants), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants), SIMATIC HMI KTP Mobile Panels, SIMATIC HMI KTP Mobile Panels (incl. SIPLUS variants), SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC PROFINET Driver, SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC WinAC RTX (F) 2010, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 PN Control Unit, SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl. Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of specially crafted UDP packets are sent to device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
"value": "A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions), SIMATIC CFU PA (All versions < V1.2.0), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions < V2.0), SIMATIC ET200AL (All versions), SIMATIC ET200M (incl. SIPLUS variants) (All versions), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants) (All versions < V4.3.0), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants) (All versions), SIMATIC ET200S (incl. SIPLUS variants) (All versions), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants) (All versions), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants) (All versions), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants) (All versions < V4.2.2), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants) (All versions), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants) (All versions), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants) (All versions < V4.2.2), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants) (All versions < V4.2.1), SIMATIC ET200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET200pro (All versions), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP Mobile Panels (All versions), SIMATIC PN/PN Coupler (incl. SIPLUS NET variants) (All versions), SIMATIC PROFINET Driver (All versions < V2.1), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.0), SIMATIC S7-1500 Software Controller (All versions < V2.0), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions < SIMATIC WinAC RTX 2010 SP3), SINAMICS DCM (All versions < V1.5 HF1), SINAMICS DCP (All versions < V1.3), SINAMICS G110M V4.7 PN Control Unit (All versions < V4.7 SP10 HF5), SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants) (All versions < V4.7 SP10 HF5), SINAMICS G130 V4.7 Control Unit (All versions < 4.8), SINAMICS G150 Control Unit (All versions < 4.8), SINAMICS GH150 V4.7 Control Unit (All versions), SINAMICS GL150 V4.7 Control Unit (All versions), SINAMICS GM150 V4.7 Control Unit (All versions), SINAMICS S110 Control Unit (All versions), SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants) (All versions), SINAMICS S150 Control Unit (All versions < 4.8), SINAMICS SL150 V4.7 Control Unit (All versions < V4.7 HF33), SINAMICS SM120 V4.7 Control Unit (All versions), SINUMERIK 828D (All versions < V4.8 SP5), SINUMERIK 840D sl (All versions). Affected devices contain a vulnerability that allows an unauthenticated attacker\nto trigger a denial-of-service condition. The vulnerability can be triggered \nif a large amount of specially crafted UDP packets are sent to device.\n\nThe security vulnerability could be exploited by an attacker with network \naccess to the affected systems. Successful exploitation requires no system\nprivileges and no user interaction. An attacker could use the vulnerability\nto compromise availability of the device.\n\nAt the time of advisory publication no public exploitation of this security\nvulnerability was known.\n"
}
]
},

View File

@ -1,17 +1,100 @@
{
"data_type": "CVE",
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10939",
"STATE": "PUBLIC"
},
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2019-10939",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"data_type": "CVE",
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Siemens AG",
"product": {
"product_data": [
{
"product_name": "TIM 3V-IE (incl. SIPLUS NET variants)",
"version": {
"version_data": [
{
"version_value": "All versions < V2.8"
}
]
}
},
{
"product_name": "TIM 3V-IE Advanced (incl. SIPLUS NET variants)",
"version": {
"version_data": [
{
"version_value": "All versions < V2.8"
}
]
}
},
{
"product_name": "TIM 3V-IE DNP3 (incl. SIPLUS NET variants)",
"version": {
"version_data": [
{
"version_value": "All versions < V3.3"
}
]
}
},
{
"product_name": "TIM 4R-IE (incl. SIPLUS NET variants)",
"version": {
"version_data": [
{
"version_value": "All versions < V2.8"
}
]
}
},
{
"product_name": "TIM 4R-IE DNP3 (incl. SIPLUS NET variants)",
"version": {
"version_data": [
{
"version_value": "All versions < V3.3"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-489: Active Debug Code"
}
]
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A vulnerability has been identified in TIM 3V-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3), TIM 4R-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3). The affected versions contain an open debug port that is available under certain specific conditions. The vulnerability is only available if the IP address is configured to 192.168.1.2.\n\nIf available, the debug port could be exploited by an attacker with network access to the device.\nNo user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality,\nintegrity, and availability of the affected device.\n\nAt the stage of publishing this security advisory no public exploitation is known.\n"
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-359303.pdf"
}
]
}

View File

@ -53,6 +53,16 @@
}
]
}
},
{
"product_name": "SIMATIC WinAC RTX (F) 2010",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
}
@ -76,7 +86,7 @@
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.1), SIMATIC S7-300 PN/DP CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions). Affected devices contain a vulnerability that could cause a Denial-of-Service condition of the web server by sending specially crafted HTTP requests to ports 80/tcp and 443/tcp. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device\u2019s web server. Beyond the web service, no other functions or interfaces are affected by the Denial-of-Service condition."
"value": "A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.1), SIMATIC S7-300 PN/DP CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions). Affected devices contain a vulnerability that could cause a Denial-of-Service condition of the web server\nby sending specially crafted HTTP requests to ports 80/tcp and 443/tcp.\n\nThe security vulnerability could be exploited by an attacker with network access to an affected device.\nSuccessful exploitation requires no system privileges and no user interaction. An attacker could use\nthe vulnerability to compromise the availability of the device\u2019s web server.\nBeyond the web service, no other functions or interfaces are affected by the Denial-of-Service condition.\n"
}
]
},

View File

@ -79,7 +79,7 @@
"version": {
"version_data": [
{
"version_value": "All versions < V16 update 1"
"version_value": "All versions < V16 Update 1"
}
]
}
@ -179,7 +179,7 @@
"version": {
"version_data": [
{
"version_value": "All versions"
"version_value": "All versions < V16 Update 1"
}
]
}
@ -209,7 +209,7 @@
"version": {
"version_data": [
{
"version_value": "All versions < V7.5.1 Upd1"
"version_value": "All versions < V7.5.1 Update 1"
}
]
}
@ -236,7 +236,7 @@
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC NET PC Software (All versions < V16 update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14.0.1 (All versions), SIMATIC WinCC (TIA Portal) V15.1 (All versions), SIMATIC WinCC (TIA Portal) V16 (All versions), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5.1 Upd1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition. Successful exploitation requires no system privileges and no user interaction."
"value": "A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC NET PC Software (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14.0.1 (All versions), SIMATIC WinCC (TIA Portal) V15.1 (All versions), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5.1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition.\nSuccessful exploitation requires no system privileges and no user interaction.\n"
}
]
},

View File

@ -1,17 +1,280 @@
{
"data_type": "CVE",
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-19300",
"STATE": "PUBLIC"
},
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2019-19300",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"data_type": "CVE",
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Siemens AG",
"product": {
"product_data": [
{
"product_name": "KTK ATE530S",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIDOOR ATD430W",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIDOOR ATE530S COATED",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIDOOR ATE531S",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Interfacemodul IM 155-6 MF HF",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions < V2.0"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions < V2.0"
}
]
}
},
{
"product_name": "SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions >= V4.2"
}
]
}
},
{
"product_name": "SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions >= V4.2"
}
]
}
},
{
"product_name": "SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions >= V4.2"
}
]
}
},
{
"product_name": "SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions >= V4.2"
}
]
}
},
{
"product_name": "SIMATIC MICRO-DRIVE PDC",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
"version": {
"version_data": [
{
"version_value": "All versions >= V4.2"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions < V2.0"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 Software Controller",
"version": {
"version_data": [
{
"version_value": "All versions < V2.0"
}
]
}
},
{
"product_name": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC S7-400 PN/DP V7 and below CPU family (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC TDC CP51M1",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC TDC CPU555",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC WinAC RTX (F) 2010",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINAMICS S/G Control Unit w. PROFINET",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400: Uncontrolled Resource Consumption ('Resource Exhaustion')"
}
]
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A vulnerability has been identified in KTK ATE530S (All versions), SIDOOR ATD430W (All versions), SIDOOR ATE530S COATED (All versions), SIDOOR ATE531S (All versions), SIMATIC ET 200SP Interfacemodul IM 155-6 MF HF (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions < V2.0), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.0), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants) (All versions), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants) (All versions >= V4.2), SIMATIC MICRO-DRIVE PDC (All versions), SIMATIC PN/PN Coupler (incl. SIPLUS NET variants) (All versions >= V4.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.0), SIMATIC S7-1500 Software Controller (All versions < V2.0), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions), SIMATIC TDC CP51M1 (All versions), SIMATIC TDC CPU555 (All versions), SIMATIC WinAC RTX (F) 2010 (All versions), SINAMICS S/G Control Unit w. PROFINET (All versions). The Interniche-based TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service."
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-593272.pdf"
}
]
}

View File

@ -1,17 +1,120 @@
{
"data_type": "CVE",
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-19301",
"STATE": "PUBLIC"
},
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2019-19301",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"data_type": "CVE",
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Siemens AG",
"product": {
"product_data": [
{
"product_name": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC CP 443-1 (incl. SIPLUS NET variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC RF180C",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC RF182C",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400: Uncontrolled Resource Consumption ('Resource Exhaustion')"
}
]
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions), SIMATIC CP 443-1 (incl. SIPLUS NET variants) (All versions), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variants) (All versions), SIMATIC RF180C (All versions), SIMATIC RF182C (All versions). The VxWorks-based Profinet TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service."
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-102233.pdf"
}
]
}

View File

@ -1,17 +1,70 @@
{
"data_type": "CVE",
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-7574",
"STATE": "PUBLIC"
},
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-7574",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"data_type": "CVE",
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Siemens AG",
"product": {
"product_data": [
{
"product_name": "Climatix POL908 (BACnet/IP module)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "Climatix POL909 (AWM module)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')"
}
]
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions). A persistent cross-site scripting (XSS) vulnerability exists in the \"Server Config\" web interface of\nthe affected devices that could allow an attacker to inject arbitrary JavaScript code.\nThe code could be potentially executed later by another (possibly privileged) user.\n\nThe security vulnerability could be exploited by an attacker with network access to the affected system.\nSuccessful exploitation requires no system privileges. An attacker could use the vulnerability\nto compromise the confidentiality and integrity of other users' web session.\n"
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf"
}
]
}

View File

@ -1,17 +1,70 @@
{
"data_type": "CVE",
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-7575",
"STATE": "PUBLIC"
},
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-7575",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"data_type": "CVE",
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Siemens AG",
"product": {
"product_data": [
{
"product_name": "Climatix POL908 (BACnet/IP module)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "Climatix POL909 (AWM module)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
}
]
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions). A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of\nthe affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests.\nThe code could be potentially executed later by another (privileged) user.\n\nThe security vulnerability could be exploited by an attacker with network access to the affected system.\nSuccessful exploitation requires no system privileges. An attacker could use the vulnerability\nto compromise the confidentiality and integrity of other users' web sessions.\n"
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf"
}
]
}