From 87ca4539370610d397a7224c00d978e85125cc0b Mon Sep 17 00:00:00 2001 From: CVE Team Date: Wed, 8 Feb 2023 23:00:39 +0000 Subject: [PATCH] "-Synchronized-Data." --- 2023/0xxx/CVE-2023-0249.json | 103 +++++++++++++++++++++++++++++++++-- 2023/0xxx/CVE-2023-0250.json | 103 +++++++++++++++++++++++++++++++++-- 2023/0xxx/CVE-2023-0251.json | 103 +++++++++++++++++++++++++++++++++-- 2023/0xxx/CVE-2023-0669.json | 9 +++ 4 files changed, 306 insertions(+), 12 deletions(-) diff --git a/2023/0xxx/CVE-2023-0249.json b/2023/0xxx/CVE-2023-0249.json index c675ce47e16..b0e94872bb8 100644 --- a/2023/0xxx/CVE-2023-0249.json +++ b/2023/0xxx/CVE-2023-0249.json @@ -1,17 +1,112 @@ { + "data_version": "4.0", "data_type": "CVE", "data_format": "MITRE", - "data_version": "4.0", "CVE_data_meta": { "ID": "CVE-2023-0249", - "ASSIGNER": "cve@mitre.org", - "STATE": "RESERVED" + "ASSIGNER": "ics-cert@hq.dhs.gov", + "STATE": "PUBLIC" }, "description": { "description_data": [ { "lang": "eng", - "value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided." + "value": "Delta Electronics DIAScreen versions 1.2.1.23 and prior are vulnerable to out-of-bounds write, which may allow an attacker to remotely execute arbitrary code." + } + ] + }, + "problemtype": { + "problemtype_data": [ + { + "description": [ + { + "lang": "eng", + "value": "CWE-787 Out-of-bounds Write", + "cweId": "CWE-787" + } + ] + } + ] + }, + "affects": { + "vendor": { + "vendor_data": [ + { + "vendor_name": "Delta Electronics", + "product": { + "product_data": [ + { + "product_name": "DIAScreen", + "version": { + "version_data": [ + { + "version_value": "All versions", + "version_affected": "=" + } + ] + } + } + ] + } + } + ] + } + }, + "references": { + "reference_data": [ + { + "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-033-01", + "refsource": "MISC", + "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-033-01" + } + ] + }, + "generator": { + "engine": "VINCE 2.0.6", + "env": "prod", + "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-0249" + }, + "source": { + "discovery": "EXTERNAL" + }, + "solution": [ + { + "lang": "en", + "supportingMedia": [ + { + "base64": false, + "type": "text/html", + "value": "\n\nDelta Electronics released version 1.3.0 of DIAScreen (login required) and recommends users install this update on all affected systems. \n\n
" + } + ], + "value": "\nDelta Electronics released version 1.3.0 of DIAScreen https://deltaiastudio.b2clogin.com/deltaiastudio.onmicrosoft.com/oauth2/v2.0/authorize \u00a0(login required) and recommends users install this update on all affected systems. \n\n\n" + } + ], + "credits": [ + { + "lang": "en", + "value": "Natnael Samson (@NattiSamson)" + }, + { + "lang": "en", + "value": "Trend Micro\u2019s Zero Day Initiative" + } + ], + "impact": { + "cvss": [ + { + "attackComplexity": "LOW", + "attackVector": "LOCAL", + "availabilityImpact": "HIGH", + "baseScore": 7.8, + "baseSeverity": "HIGH", + "confidentialityImpact": "HIGH", + "integrityImpact": "HIGH", + "privilegesRequired": "NONE", + "scope": "UNCHANGED", + "userInteraction": "REQUIRED", + "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", + "version": "3.1" } ] } diff --git a/2023/0xxx/CVE-2023-0250.json b/2023/0xxx/CVE-2023-0250.json index f6e67118a1e..664725e1fcf 100644 --- a/2023/0xxx/CVE-2023-0250.json +++ b/2023/0xxx/CVE-2023-0250.json @@ -1,17 +1,112 @@ { + "data_version": "4.0", "data_type": "CVE", "data_format": "MITRE", - "data_version": "4.0", "CVE_data_meta": { "ID": "CVE-2023-0250", - "ASSIGNER": "cve@mitre.org", - "STATE": "RESERVED" + "ASSIGNER": "ics-cert@hq.dhs.gov", + "STATE": "PUBLIC" }, "description": { "description_data": [ { "lang": "eng", - "value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided." + "value": "Delta Electronics DIAScreen versions 1.2.1.23 and prior are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code." + } + ] + }, + "problemtype": { + "problemtype_data": [ + { + "description": [ + { + "lang": "eng", + "value": "CWE-121 STACK-BASED BUFFER OVERFLOW", + "cweId": "CWE-121" + } + ] + } + ] + }, + "affects": { + "vendor": { + "vendor_data": [ + { + "vendor_name": "Delta Electronics", + "product": { + "product_data": [ + { + "product_name": "DIAScreen", + "version": { + "version_data": [ + { + "version_value": "All versions", + "version_affected": "=" + } + ] + } + } + ] + } + } + ] + } + }, + "references": { + "reference_data": [ + { + "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-033-01", + "refsource": "MISC", + "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-033-01" + } + ] + }, + "generator": { + "engine": "VINCE 2.0.6", + "env": "prod", + "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-0250" + }, + "source": { + "discovery": "EXTERNAL" + }, + "solution": [ + { + "lang": "en", + "supportingMedia": [ + { + "base64": false, + "type": "text/html", + "value": "\n\nDelta Electronics released version 1.3.0 of DIAScreen (login required) and recommends users install this update on all affected systems. \n\n
" + } + ], + "value": "\nDelta Electronics released version 1.3.0 of DIAScreen https://deltaiastudio.b2clogin.com/deltaiastudio.onmicrosoft.com/oauth2/v2.0/authorize \u00a0(login required) and recommends users install this update on all affected systems. \n\n\n" + } + ], + "credits": [ + { + "lang": "en", + "value": "Natnael Samson (@NattiSamson)" + }, + { + "lang": "en", + "value": "Trend Micro\u2019s Zero Day Initiative" + } + ], + "impact": { + "cvss": [ + { + "attackComplexity": "LOW", + "attackVector": "LOCAL", + "availabilityImpact": "HIGH", + "baseScore": 7.8, + "baseSeverity": "HIGH", + "confidentialityImpact": "HIGH", + "integrityImpact": "HIGH", + "privilegesRequired": "NONE", + "scope": "UNCHANGED", + "userInteraction": "REQUIRED", + "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", + "version": "3.1" } ] } diff --git a/2023/0xxx/CVE-2023-0251.json b/2023/0xxx/CVE-2023-0251.json index fb24424d5e1..76fea0628a0 100644 --- a/2023/0xxx/CVE-2023-0251.json +++ b/2023/0xxx/CVE-2023-0251.json @@ -1,17 +1,112 @@ { + "data_version": "4.0", "data_type": "CVE", "data_format": "MITRE", - "data_version": "4.0", "CVE_data_meta": { "ID": "CVE-2023-0251", - "ASSIGNER": "cve@mitre.org", - "STATE": "RESERVED" + "ASSIGNER": "ics-cert@hq.dhs.gov", + "STATE": "PUBLIC" }, "description": { "description_data": [ { "lang": "eng", - "value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided." + "value": "Delta Electronics DIAScreen versions 1.2.1.23 and prior are vulnerable to a buffer overflow through improper restrictions of operations within memory, which could allow an attacker to remotely execute arbitrary code." + } + ] + }, + "problemtype": { + "problemtype_data": [ + { + "description": [ + { + "lang": "eng", + "value": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer", + "cweId": "CWE-119" + } + ] + } + ] + }, + "affects": { + "vendor": { + "vendor_data": [ + { + "vendor_name": "Delta Electronics", + "product": { + "product_data": [ + { + "product_name": "DIAScreen", + "version": { + "version_data": [ + { + "version_value": "All versions", + "version_affected": "=" + } + ] + } + } + ] + } + } + ] + } + }, + "references": { + "reference_data": [ + { + "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-033-01", + "refsource": "MISC", + "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-033-01" + } + ] + }, + "generator": { + "engine": "VINCE 2.0.6", + "env": "prod", + "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-0251" + }, + "source": { + "discovery": "EXTERNAL" + }, + "solution": [ + { + "lang": "en", + "supportingMedia": [ + { + "base64": false, + "type": "text/html", + "value": "\n\nDelta Electronics released version 1.3.0 of DIAScreen (login required) and recommends users install this update on all affected systems. \n\n
" + } + ], + "value": "\nDelta Electronics released version 1.3.0 of DIAScreen https://deltaiastudio.b2clogin.com/deltaiastudio.onmicrosoft.com/oauth2/v2.0/authorize \u00a0(login required) and recommends users install this update on all affected systems. \n\n\n" + } + ], + "credits": [ + { + "lang": "en", + "value": "Natnael Samson (@NattiSamson)" + }, + { + "lang": "en", + "value": "Trend Micro\u2019s Zero Day Initiative" + } + ], + "impact": { + "cvss": [ + { + "attackComplexity": "LOW", + "attackVector": "LOCAL", + "availabilityImpact": "HIGH", + "baseScore": 7.8, + "baseSeverity": "HIGH", + "confidentialityImpact": "HIGH", + "integrityImpact": "HIGH", + "privilegesRequired": "NONE", + "scope": "UNCHANGED", + "userInteraction": "REQUIRED", + "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", + "version": "3.1" } ] } diff --git a/2023/0xxx/CVE-2023-0669.json b/2023/0xxx/CVE-2023-0669.json index d8dcdc35422..083c55c4dca 100644 --- a/2023/0xxx/CVE-2023-0669.json +++ b/2023/0xxx/CVE-2023-0669.json @@ -83,6 +83,11 @@ "url": "https://duo.com/decipher/fortra-patches-actively-exploited-zero-day-in-goanywhere-mft", "refsource": "MISC", "name": "https://duo.com/decipher/fortra-patches-actively-exploited-zero-day-in-goanywhere-mft" + }, + { + "url": "https://frycos.github.io/vulns4free/2023/02/06/goanywhere-forgotten.html", + "refsource": "MISC", + "name": "https://frycos.github.io/vulns4free/2023/02/06/goanywhere-forgotten.html" } ] }, @@ -104,6 +109,10 @@ { "lang": "en", "value": "Caitlin Condon of Rapid7" + }, + { + "lang": "en", + "value": "Fryco of Frycos Security" } ] } \ No newline at end of file