"-Synchronized-Data."

This commit is contained in:
CVE Team 2024-01-29 03:00:33 +00:00
parent a2f2484713
commit 88e85430b7
No known key found for this signature in database
GPG Key ID: E3252B3D49582C98
2 changed files with 182 additions and 8 deletions

View File

@ -1,17 +1,104 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2024-0995",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "cna@vuldb.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A vulnerability was found in Tenda W6 1.0.0.9(4122). It has been rated as critical. Affected by this issue is the function formwrlSSIDset of the file /goform/wifiSSIDset of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252260. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "deu",
"value": "Eine kritische Schwachstelle wurde in Tenda W6 1.0.0.9(4122) ausgemacht. Davon betroffen ist die Funktion formwrlSSIDset der Datei /goform/wifiSSIDset der Komponente httpd. Durch Manipulieren des Arguments index mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121 Stack-based Buffer Overflow",
"cweId": "CWE-121"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Tenda",
"product": {
"product_data": [
{
"product_name": "W6",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "1.0.0.9(4122)"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://vuldb.com/?id.252260",
"refsource": "MISC",
"name": "https://vuldb.com/?id.252260"
},
{
"url": "https://vuldb.com/?ctiid.252260",
"refsource": "MISC",
"name": "https://vuldb.com/?ctiid.252260"
},
{
"url": "https://jylsec.notion.site/Tenda-w6-has-stack-buffer-overflow-vulnerability-in-formwrlSSIDset-e283b41905934e97b4c65632a0018eba?pvs=4",
"refsource": "MISC",
"name": "https://jylsec.notion.site/Tenda-w6-has-stack-buffer-overflow-vulnerability-in-formwrlSSIDset-e283b41905934e97b4c65632a0018eba?pvs=4"
}
]
},
"credits": [
{
"lang": "en",
"value": "jylsec (VulDB User)"
}
],
"impact": {
"cvss": [
{
"version": "3.1",
"baseScore": 7.2,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"baseSeverity": "HIGH"
},
{
"version": "3.0",
"baseScore": 7.2,
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"baseSeverity": "HIGH"
},
{
"version": "2.0",
"baseScore": 8.3,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C"
}
]
}

View File

@ -1,17 +1,104 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2024-0996",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "cna@vuldb.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A vulnerability classified as critical has been found in Tenda i9 1.0.0.9(4122). This affects the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252261 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "deu",
"value": "Es wurde eine Schwachstelle in Tenda i9 1.0.0.9(4122) entdeckt. Sie wurde als kritisch eingestuft. Hiervon betroffen ist die Funktion formSetCfm der Datei /goform/setcfm der Komponente httpd. Durch das Beeinflussen des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121 Stack-based Buffer Overflow",
"cweId": "CWE-121"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Tenda",
"product": {
"product_data": [
{
"product_name": "i9",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "1.0.0.9(4122)"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://vuldb.com/?id.252261",
"refsource": "MISC",
"name": "https://vuldb.com/?id.252261"
},
{
"url": "https://vuldb.com/?ctiid.252261",
"refsource": "MISC",
"name": "https://vuldb.com/?ctiid.252261"
},
{
"url": "https://jylsec.notion.site/Tenda-i9-has-stack-buffer-overflow-vulnerability-in-formSetCfm-c1bd9745c81e4207aceeaa1ba5e10563?pvs=4",
"refsource": "MISC",
"name": "https://jylsec.notion.site/Tenda-i9-has-stack-buffer-overflow-vulnerability-in-formSetCfm-c1bd9745c81e4207aceeaa1ba5e10563?pvs=4"
}
]
},
"credits": [
{
"lang": "en",
"value": "jylsec (VulDB User)"
}
],
"impact": {
"cvss": [
{
"version": "3.1",
"baseScore": 7.2,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"baseSeverity": "HIGH"
},
{
"version": "3.0",
"baseScore": 7.2,
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"baseSeverity": "HIGH"
},
{
"version": "2.0",
"baseScore": 8.3,
"vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C"
}
]
}