"-Synchronized-Data."

This commit is contained in:
CVE Team 2022-12-27 19:00:41 +00:00
parent 7bd3a22f8d
commit 8e808b7018
No known key found for this signature in database
GPG Key ID: E3252B3D49582C98
2 changed files with 76 additions and 6 deletions

View File

@ -19,7 +19,7 @@
"version": {
"version_data": [
{
"version_value": "FFmpg n5.2-dev"
"version_value": "FFmpeg 5.1"
}
]
}
@ -60,7 +60,7 @@
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in the FFmpeg through 3.0. vp3_decode_frame in libavcodec/vp3.c lacks check of the return value of av_malloc() and will cause the null pointer dereference, impacting confidentiality and availability."
"value": "An issue was discovered in the FFmpeg package, where vp3_decode_frame in libavcodec/vp3.c lacks check of the return value of av_malloc() and will cause a null pointer dereference, impacting availability."
}
]
}

View File

@ -1,17 +1,87 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2022-3156",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "PSIRT@rockwellautomation.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A remote code execution vulnerability exists in Rockwell Automation Studio 5000 Logix Emulate software. Users are granted elevated permissions on certain product services when the software is installed. Due to this misconfiguration, a malicious user could potentially achieve remote code execution on the targeted software."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287 Improper Authentication",
"cweId": "CWE-287"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Rockwell Automation",
"product": {
"product_data": [
{
"product_name": "Studio 5000 Logix Emulate",
"version": {
"version_data": [
{
"version_value": "20.011 ",
"version_affected": "="
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137846",
"refsource": "MISC",
"name": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137846"
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"source": {
"discovery": "UNKNOWN"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
]
}