"-Synchronized-Data."

This commit is contained in:
CVE Team 2022-06-08 15:01:32 +00:00
parent fec7907124
commit 9d60264cc2
No known key found for this signature in database
GPG Key ID: E3252B3D49582C98
4 changed files with 229 additions and 12 deletions

View File

@ -4,14 +4,58 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-14125",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "security@xiaomi.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "Redmi Note 11 ,Redmi Note 9T",
"version": {
"version_data": [
{
"version_value": "Redmi Note 11 MIUI<2022.01.26, Redmi Note 9T MIUI<2022.01.26"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Denial of service vulnerability"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://trust.mi.com/zh-CN/misrc/bulletins/advisory?cveId=170",
"url": "https://trust.mi.com/zh-CN/misrc/bulletins/advisory?cveId=170"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A denial of service vulnerability exists in some Xiaomi models of phones. The vulnerability is caused by out-of-bound read/write and can be exploited by attackers to make denial of service."
}
]
}

View File

@ -1,17 +1,61 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2021-36710",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ID": "CVE-2021-36710",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "ToaruOS 1.99.2 is affected by incorrect access control via the kernel. Improper MMU management and having a low GDT address allows it to be mapped in userland. A call gate can then be written to escalate to CPL 0."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"url": "https://github.com/mehsauce/kowasuos/blob/master/exploits/kowasu-sysfunc-strikes-back.c",
"refsource": "MISC",
"name": "https://github.com/mehsauce/kowasuos/blob/master/exploits/kowasu-sysfunc-strikes-back.c"
}
]
}

View File

@ -4,14 +4,125 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2022-24296",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "Air Conditioning System G-150AD; Air Conditioning System AG-150A-A; Air Conditioning System AG-150A-J; Air Conditioning System GB-50AD; Air Conditioning System GB-50ADA-A; Air Conditioning System GB-50ADA-J; Air Conditioning System EB-50GU-A; Air Conditioning System EB-50GU-J; Air Conditioning System AE-200J; Air Conditioning System AE-200A; Air Conditioning System AE-200E; Air Conditioning System AE-50J; Air Conditioning System AE-50A; Air Conditioning System AE-50E; Air Conditioning System EW-50J; Air Conditioning System EW-50A; Air Conditioning System EW-50E; Air Conditioning System TE-200A; Air Conditioning System TE-50A; Air Conditioning System TW-50A",
"version": {
"version_data": [
{
"version_value": "Air Conditioning System G-150AD Ver. 3.21 and prior"
},
{
"version_value": "Air Conditioning System AG-150A-A Ver. 3.21 and prior"
},
{
"version_value": "Air Conditioning System AG-150A-J Ver. 3.21 and prior"
},
{
"version_value": "Air Conditioning System GB-50AD Ver. 3.21 and prior"
},
{
"version_value": "Air Conditioning System GB-50ADA-A Ver. 3.21 and prior"
},
{
"version_value": "Air Conditioning System GB-50ADA-J Ver. 3.21 and prior"
},
{
"version_value": "Air Conditioning System EB-50GU-A Ver. 7.10 and prior"
},
{
"version_value": "Air Conditioning System EB-50GU-J Ver. 7.10 and prior"
},
{
"version_value": "Air Conditioning System AE-200J Ver. 7.97 and prior"
},
{
"version_value": "Air Conditioning System AE-200A Ver. 7.97 and prior"
},
{
"version_value": "Air Conditioning System AE-200E Ver. 7.97 and prior"
},
{
"version_value": "Air Conditioning System AE-50J Ver. 7.97 and prior"
},
{
"version_value": "Air Conditioning System AE-50A Ver. 7.97 and prior"
},
{
"version_value": "Air Conditioning System AE-50E Ver. 7.97 and prior"
},
{
"version_value": "Air Conditioning System EW-50J Ver. 7.97 and prior"
},
{
"version_value": "Air Conditioning System EW-50A Ver. 7.97 and prior"
},
{
"version_value": "Air Conditioning System EW-50E Ver. 7.97 and prior"
},
{
"version_value": "Air Conditioning System TE-200A Ver. 7.97 and prior"
},
{
"version_value": "Air Conditioning System TE-50A Ver. 7.97 and prior"
},
{
"version_value": "Air Conditioning System TW-50A Ver. 7.97 and prior"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Use of a Broken or Risky Cryptographic Algorithm"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-005_en.pdf",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-005_en.pdf"
},
{
"refsource": "MISC",
"name": "https://www.mee.co.jp/psirt/vulnerability/pdf/2022-001.pdf",
"url": "https://www.mee.co.jp/psirt/vulnerability/pdf/2022-001.pdf"
},
{
"refsource": "MISC",
"name": "https://jvn.jp/vu/JVNVU95298925/index.html",
"url": "https://jvn.jp/vu/JVNVU95298925/index.html"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditioning System GB-50ADA-A Ver. 3.21 and prior, Air Conditioning System GB-50ADA-J Ver. 3.21 and prior, Air Conditioning System EB-50GU-A Ver. 7.10 and prior, Air Conditioning System EB-50GU-J Ver. 7.10 and prior, Air Conditioning System AE-200J Ver. 7.97 and prior, Air Conditioning System AE-200A Ver. 7.97 and prior, Air Conditioning System AE-200E Ver. 7.97 and prior, Air Conditioning System AE-50J Ver. 7.97 and prior, Air Conditioning System AE-50A Ver. 7.97 and prior, Air Conditioning System AE-50E Ver. 7.97 and prior, Air Conditioning System EW-50J Ver. 7.97 and prior, Air Conditioning System EW-50A Ver. 7.97 and prior, Air Conditioning System EW-50E Ver. 7.97 and prior, Air Conditioning System TE-200A Ver. 7.97 and prior, Air Conditioning System TE-50A Ver. 7.97 and prior and Air Conditioning System TW-50A Ver. 7.97 and prior allows a remote unauthenticated attacker to cause a disclosure of encrypted message of the air conditioning systems by sniffing encrypted communications."
}
]
}

View File

@ -0,0 +1,18 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2022-32549",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
}
]
}
}