"-Synchronized-Data."

This commit is contained in:
CVE Team 2024-05-03 02:05:54 +00:00
parent a1aeb25f5c
commit a7a1a93094
No known key found for this signature in database
GPG Key ID: BC5FD8F2443B23B7
28 changed files with 1922 additions and 112 deletions

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38111",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Foxit PDF Reader Annotation Use-After-Free Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Foxit PDF Reader. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the handling of Annotation objects. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-21025."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-416: Use After Free",
"cweId": "CWE-416"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Foxit",
"product": {
"product_data": [
{
"product_name": "PDF Reader",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "12.1.2.15332"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-989/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-989/"
},
{
"url": "https://www.foxit.com/support/security-bulletins.html",
"refsource": "MISC",
"name": "https://www.foxit.com/support/security-bulletins.html"
}
]
},
"source": {
"lang": "en",
"value": "Anonymous"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38112",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Foxit PDF Reader XFA Annotation Use-After-Free Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Foxit PDF Reader. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the handling of Annotation objects. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-21062."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-416: Use After Free",
"cweId": "CWE-416"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Foxit",
"product": {
"product_data": [
{
"product_name": "PDF Reader",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "12.1.2.15332"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-990/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-990/"
},
{
"url": "https://www.foxit.com/support/security-bulletins.html",
"refsource": "MISC",
"name": "https://www.foxit.com/support/security-bulletins.html"
}
]
},
"source": {
"lang": "en",
"value": "Anonymous"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38113",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Foxit PDF Reader Annotation Use-After-Free Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Foxit PDF Reader. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the handling of Annotation objects. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-21083."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-416: Use After Free",
"cweId": "CWE-416"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Foxit",
"product": {
"product_data": [
{
"product_name": "PDF Reader",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "12.1.2.15332"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-991/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-991/"
},
{
"url": "https://www.foxit.com/support/security-bulletins.html",
"refsource": "MISC",
"name": "https://www.foxit.com/support/security-bulletins.html"
}
]
},
"source": {
"lang": "en",
"value": "Anonymous"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"baseScore": 3.3,
"baseSeverity": "LOW"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38114",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Foxit PDF Reader AcroForm Doc Object Use-After-Free Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Foxit PDF Reader. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the handling of Doc objects. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-21085."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-416: Use After Free",
"cweId": "CWE-416"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Foxit",
"product": {
"product_data": [
{
"product_name": "PDF Reader",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "12.1.2.15332"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-992/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-992/"
},
{
"url": "https://www.foxit.com/support/security-bulletins.html",
"refsource": "MISC",
"name": "https://www.foxit.com/support/security-bulletins.html"
}
]
},
"source": {
"lang": "en",
"value": "Anonymous"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38115",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Foxit PDF Reader AcroForm Out-Of-Bounds Read Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Foxit PDF Reader. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the handling of Doc objects. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-21256."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read",
"cweId": "CWE-125"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Foxit",
"product": {
"product_data": [
{
"product_name": "PDF Reader",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "12.1.2.15332"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-993/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-993/"
},
{
"url": "https://www.foxit.com/support/security-bulletins.html",
"refsource": "MISC",
"name": "https://www.foxit.com/support/security-bulletins.html"
}
]
},
"source": {
"lang": "en",
"value": "Mat Powell of Trend Micro Zero Day Initiative"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"baseScore": 3.3,
"baseSeverity": "LOW"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38116",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Foxit PDF Reader Doc Object Out-Of-Bounds Read Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Foxit PDF Reader. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the handling of Doc objects. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-21292."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read",
"cweId": "CWE-125"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Foxit",
"product": {
"product_data": [
{
"product_name": "PDF Reader",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "12.1.2.15332"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-994/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-994/"
},
{
"url": "https://www.foxit.com/support/security-bulletins.html",
"refsource": "MISC",
"name": "https://www.foxit.com/support/security-bulletins.html"
}
]
},
"source": {
"lang": "en",
"value": "Anonymous"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"baseScore": 3.3,
"baseSeverity": "LOW"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38117",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Foxit PDF Reader AcroForm Doc Object Use-After-Free Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Foxit PDF Reader. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the handling of Doc objects. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-21293."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-416: Use After Free",
"cweId": "CWE-416"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Foxit",
"product": {
"product_data": [
{
"product_name": "PDF Reader",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "12.1.2.15332"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-995/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-995/"
},
{
"url": "https://www.foxit.com/support/security-bulletins.html",
"refsource": "MISC",
"name": "https://www.foxit.com/support/security-bulletins.html"
}
]
},
"source": {
"lang": "en",
"value": "Anonymous"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38118",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Foxit PDF Reader AcroForm Doc Object Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Foxit PDF Reader. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the handling of Doc objects. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-21325."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write",
"cweId": "CWE-787"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Foxit",
"product": {
"product_data": [
{
"product_name": "PDF Reader",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "12.1.2.15332"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-996/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-996/"
},
{
"url": "https://www.foxit.com/support/security-bulletins.html",
"refsource": "MISC",
"name": "https://www.foxit.com/support/security-bulletins.html"
}
]
},
"source": {
"lang": "en",
"value": "Anonymous"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38119",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Foxit PDF Reader AcroForm signature Out-Of-Bounds Read Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Foxit PDF Reader. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the handling of signature fields. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-21326."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read",
"cweId": "CWE-125"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Foxit",
"product": {
"product_data": [
{
"product_name": "PDF Reader",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "12.1.2.15332"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-997/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-997/"
},
{
"url": "https://www.foxit.com/support/security-bulletins.html",
"refsource": "MISC",
"name": "https://www.foxit.com/support/security-bulletins.html"
}
]
},
"source": {
"lang": "en",
"value": "Anonymous"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,77 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38120",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Adtran SR400ac ping Command Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Adtran SR400ac routers. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the ping command, which is available over JSON-RPC. A crafted host parameter can trigger execution of a system call composed from a user-supplied string. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-20525."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')",
"cweId": "CWE-78"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Adtran",
"product": {
"product_data": [
{
"product_name": "SR400ac",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "R.47.0.0 AutoCAD 2021 & R.47.0.0 AutoCAD LT 2021"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1010/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-1010/"
}
]
},
"source": {
"lang": "en",
"value": "ther3d0ne - https://thered0ne.com"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 8.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38121",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Inductive Automation Ignition OPC UA Quick Client Cross-Site Scripting Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the handling of the id parameter provided to the Inductive Automation Ignition web interface. The issue results from the lack of proper validation of user-supplied data, which can lead to the injection of an arbitrary script. An attacker can leverage this vulnerability to execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-20355."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')",
"cweId": "CWE-79"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Inductive Automation",
"product": {
"product_data": [
{
"product_name": "Ignition",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "8.1.24"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1012/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-1012/"
},
{
"url": "https://inductiveautomation.com/blog/inductive-automation-participates-in-pwn2own-to-strengthen-ignition-security",
"refsource": "MISC",
"name": "https://inductiveautomation.com/blog/inductive-automation-participates-in-pwn2own-to-strengthen-ignition-security"
}
]
},
"source": {
"lang": "en",
"value": "20urdjk"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
"baseScore": 8.3,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38122",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Inductive Automation Ignition OPC UA Quick Client Permissive Cross-domain Policy Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the configuration of the web server. The issue results from the lack of appropriate Content Security Policy headers. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of SYSTEM. Was ZDI-CAN-20539."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-942: Permissive Cross-domain Policy with Untrusted Domains",
"cweId": "CWE-942"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Inductive Automation",
"product": {
"product_data": [
{
"product_name": "Ignition",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "8.1.24"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1013/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-1013/"
},
{
"url": "https://inductiveautomation.com/blog/inductive-automation-participates-in-pwn2own-to-strengthen-ignition-security",
"refsource": "MISC",
"name": "https://inductiveautomation.com/blog/inductive-automation-participates-in-pwn2own-to-strengthen-ignition-security"
}
]
},
"source": {
"lang": "en",
"value": "20urdjk"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 7.2,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38123",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Inductive Automation Ignition OPC UA Quick Client Missing Authentication for Critical Function Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the server configuration. The issue results from the lack of authentication prior to allowing access to password change functionality. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-20540."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306: Missing Authentication for Critical Function",
"cweId": "CWE-306"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Inductive Automation",
"product": {
"product_data": [
{
"product_name": "Ignition",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "8.1.24"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1014/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-1014/"
},
{
"url": "https://inductiveautomation.com/blog/inductive-automation-participates-in-pwn2own-to-strengthen-ignition-security",
"refsource": "MISC",
"name": "https://inductiveautomation.com/blog/inductive-automation-participates-in-pwn2own-to-strengthen-ignition-security"
}
]
},
"source": {
"lang": "en",
"value": "20urdjk"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.5,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38124",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Inductive Automation Ignition OPC UA Quick Client Task Scheduling Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the Ignition Gateway server. The issue results from the exposure of a dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20541."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-749: Exposed Dangerous Method or Function",
"cweId": "CWE-749"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Inductive Automation",
"product": {
"product_data": [
{
"product_name": "Ignition",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "8.1.24"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1015/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-1015/"
},
{
"url": "https://inductiveautomation.com/blog/inductive-automation-participates-in-pwn2own-to-strengthen-ignition-security",
"refsource": "MISC",
"name": "https://inductiveautomation.com/blog/inductive-automation-participates-in-pwn2own-to-strengthen-ignition-security"
}
]
},
"source": {
"lang": "en",
"value": "20urdjk"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 7.2,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,77 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38125",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Softing edgeAggregator Permissive Cross-domain Policy with Untrusted Domains Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Softing edgeAggregator. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the configuration of the web server. The issue results from the lack of appropriate Content Security Policy headers. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20542."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-942: Permissive Cross-domain Policy with Untrusted Domains",
"cweId": "CWE-942"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Softing",
"product": {
"product_data": [
{
"product_name": "edgeAggregator",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "3.40"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1059/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-1059/"
}
]
},
"source": {
"lang": "en",
"value": "Claroty Research - Team82 - Uri Katz, Noam Moshe, Vera Mens, Sharon Brizinov"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 7.5,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-39457",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists due to the lack of user authentication. The issue results from missing authentication in the default system configuration. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20501."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306: Missing Authentication for Critical Function",
"cweId": "CWE-306"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Triangle MicroWorks",
"product": {
"product_data": [
{
"product_name": "SCADA Data Gateway",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.1.3.20324"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1025/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-1025/"
},
{
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new",
"refsource": "MISC",
"name": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new"
}
]
},
"source": {
"lang": "en",
"value": "Claroty Research - Team82 - Uri Katz, Noam Moshe, Vera Mens, Sharon Brizinov"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-39458",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of certificates. The service uses a hard-coded default SSL certificate. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-20509."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-798: Use of Hard-coded Credentials",
"cweId": "CWE-798"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Triangle MicroWorks",
"product": {
"product_data": [
{
"product_name": "SCADA Data Gateway",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.1.3.20324"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1026/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-1026/"
},
{
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new",
"refsource": "MISC",
"name": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new"
}
]
},
"source": {
"lang": "en",
"value": "Team ECQ"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"baseScore": 5.3,
"baseSeverity": "MEDIUM"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-39459",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Triangle MicroWorks SCADA Data Gateway Directory Traversal Arbitrary File Creation Vulnerability. This vulnerability allows remote attackers to create arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the processing of workspace files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to create files in the context of Administrator. Was ZDI-CAN-20531."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')",
"cweId": "CWE-22"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Triangle MicroWorks",
"product": {
"product_data": [
{
"product_name": "SCADA Data Gateway",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.1.3"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1027/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-1027/"
},
{
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new",
"refsource": "MISC",
"name": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new"
}
]
},
"source": {
"lang": "en",
"value": "Li Jiantao, Ngo Wei Lin, Pan Zhenpeng of STAR Labs SG Pte. Ltd."
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-39460",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Triangle MicroWorks SCADA Data Gateway Event Log Directory Traversal Arbitrary File Creation Vulnerability. This vulnerability allows remote attackers to create arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the creation of event logs. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20534."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')",
"cweId": "CWE-22"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Triangle MicroWorks",
"product": {
"product_data": [
{
"product_name": "SCADA Data Gateway",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.1.3.20324"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1028/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-1028/"
},
{
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new",
"refsource": "MISC",
"name": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new"
}
]
},
"source": {
"lang": "en",
"value": "Claroty Research - Team82 - Uri Katz, Noam Moshe, Vera Mens, Sharon Brizinov"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 7.2,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-39461",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Triangle MicroWorks SCADA Data Gateway Event Log Improper Output Neutralization For Logs Arbitrary File Write Vulnerability. This vulnerability allows remote attackers to write arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the handling of event logs. The issue results from improper sanitization of log output. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20535."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-117: Improper Output Neutralization for Logs",
"cweId": "CWE-117"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Triangle MicroWorks",
"product": {
"product_data": [
{
"product_name": "SCADA Data Gateway",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.1.3.20324"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1029/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-1029/"
},
{
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new",
"refsource": "MISC",
"name": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new"
}
]
},
"source": {
"lang": "en",
"value": "Claroty Research - Team82 - Uri Katz, Noam Moshe, Vera Mens, Sharon Brizinov"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:N",
"baseScore": 4.4,
"baseSeverity": "MEDIUM"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-39462",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Triangle MicroWorks SCADA Data Gateway Workspace Unrestricted Upload Vulnerability. This vulnerability allows remote attackers to upload arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the processing of workspace files. The issue results from the lack of proper validation of user-supplied data, which can allow the upload of arbitrary files. An attacker can leverage this in conjunction with other vulnerabilitites to execute arbitrary code in the context of root. Was ZDI-CAN-20536."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-434: Unrestricted Upload of File with Dangerous Type",
"cweId": "CWE-434"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Triangle MicroWorks",
"product": {
"product_data": [
{
"product_name": "SCADA Data Gateway",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.1.3.20324"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1030/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-1030/"
},
{
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new",
"refsource": "MISC",
"name": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new"
}
]
},
"source": {
"lang": "en",
"value": "Claroty Research - Team82 - Uri Katz, Noam Moshe, Vera Mens, Sharon Brizinov"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"baseScore": 6.5,
"baseSeverity": "MEDIUM"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-39463",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Triangle MicroWorks SCADA Data Gateway Trusted Certification Unrestricted Upload of File Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the trusted certification feature. The issue lies in the handling of the OpcUaSecurityCertificateAuthorityTrustDir variable, which allows an arbitrary file write with attacker-controlled data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20537."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-434: Unrestricted Upload of File with Dangerous Type",
"cweId": "CWE-434"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Triangle MicroWorks",
"product": {
"product_data": [
{
"product_name": "SCADA Data Gateway",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.1.3.20324"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1031/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-1031/"
},
{
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new",
"refsource": "MISC",
"name": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new"
}
]
},
"source": {
"lang": "en",
"value": "Team ECQ"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 7.2,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-39464",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the configuration of the GTWWebMonitorService service. The path to the service executable contains spaces not surrounded by quotations. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20538."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-428: Unquoted Search Path or Element",
"cweId": "CWE-428"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Triangle MicroWorks",
"product": {
"product_data": [
{
"product_name": "SCADA Data Gateway",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.1.3.20324"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1032/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-1032/"
},
{
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new",
"refsource": "MISC",
"name": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new"
}
]
},
"source": {
"lang": "en",
"value": "Team ECQ"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 7.2,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-39465",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Cryptograhic Key Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the TmwCrypto class. The issue results from the usage of a hard-coded cryptograhic key and the usage of a hard-coded certificate. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20615."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-321: Use of Hard-coded Cryptographic Key",
"cweId": "CWE-321"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Triangle MicroWorks",
"product": {
"product_data": [
{
"product_name": "SCADA Data Gateway",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.1.3.20324"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1033/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-1033/"
},
{
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new",
"refsource": "MISC",
"name": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new"
}
]
},
"source": {
"lang": "en",
"value": "Uri Katz of Claroty Team82"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"baseScore": 7.5,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-39466",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Triangle MicroWorks SCADA Data Gateway get_config Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the get_config endpoint. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20797."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306: Missing Authentication for Critical Function",
"cweId": "CWE-306"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Triangle MicroWorks",
"product": {
"product_data": [
{
"product_name": "SCADA Data Gateway",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.1.3.20324"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1034/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-1034/"
},
{
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new",
"refsource": "MISC",
"name": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new"
}
]
},
"source": {
"lang": "en",
"value": "Uri Katz of Claroty Team82"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"baseScore": 5.3,
"baseSeverity": "MEDIUM"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-39467",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Triangle MicroWorks SCADA Data Gateway certificate Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the configuration of certificate web directory. The issue results from the exposure of sensitive information in the application webroot. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20798."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-219: Storage of File with Sensitive Data Under Web Root",
"cweId": "CWE-219"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Triangle MicroWorks",
"product": {
"product_data": [
{
"product_name": "SCADA Data Gateway",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.1.3.20324"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1035/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-1035/"
},
{
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new",
"refsource": "MISC",
"name": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new"
}
]
},
"source": {
"lang": "en",
"value": "Uri Katz of Claroty Team82"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"baseScore": 5.3,
"baseSeverity": "MEDIUM"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-39468",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of DbasSectorFileToExecuteOnReset parameter. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20799."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-749: Exposed Dangerous Method or Function",
"cweId": "CWE-749"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Triangle MicroWorks",
"product": {
"product_data": [
{
"product_name": "SCADA Data Gateway",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.1.3.20324"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1036/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-1036/"
},
{
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new",
"refsource": "MISC",
"name": "https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new"
}
]
},
"source": {
"lang": "en",
"value": "Uri Katz of Claroty Team82"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 7.2,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-39469",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "PaperCut NG External User Lookup Code Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of PaperCut NG. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the External User Lookup functionality. The issue results from the lack of proper validation of a user-supplied string before using it to execute Java code. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-21013."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-94: Improper Control of Generation of Code ('Code Injection')",
"cweId": "CWE-94"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "PaperCut",
"product": {
"product_data": [
{
"product_name": "NG",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "22.0.12"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1285/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-1285/"
},
{
"url": "https://www.papercut.com/kb/Main/SecurityBulletinJuly2023/",
"refsource": "MISC",
"name": "https://www.papercut.com/kb/Main/SecurityBulletinJuly2023/"
}
]
},
"source": {
"lang": "en",
"value": "Anonymous"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 7.2,
"baseSeverity": "HIGH"
}
]
}