- Added submission from ICS-CERT for ICSA-18-263-01 from 2018-09-20.

This commit is contained in:
CVE Team 2018-09-20 14:18:48 -04:00
parent 52ab9a12a5
commit aa7d13dd93
No known key found for this signature in database
GPG Key ID: 0DA1F9F56BC892E8

View File

@ -1,8 +1,32 @@
{
"CVE_data_meta" : {
"ASSIGNER" : "cve@mitre.org",
"ASSIGNER" : "ics-cert@hq.dhs.gov",
"DATE_PUBLIC" : "2018-09-20T00:00:00",
"ID" : "CVE-2018-14796",
"STATE" : "RESERVED"
"STATE" : "PUBLIC"
},
"affects" : {
"vendor" : {
"vendor_data" : [
{
"product" : {
"product_data" : [
{
"product_name" : "SmartCooler",
"version" : {
"version_data" : [
{
"version_value" : "all versions prior to firmware 180806"
}
]
}
}
]
},
"vendor_name" : "Tec4Data"
}
]
}
},
"data_format" : "MITRE",
"data_type" : "CVE",
@ -11,7 +35,26 @@
"description_data" : [
{
"lang" : "eng",
"value" : "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value" : "Tec4Data SmartCooler, all versions prior to firmware 180806, the device responds to a remote unauthenticated reboot command that may be used to perform a denial of service attack."
}
]
},
"problemtype" : {
"problemtype_data" : [
{
"description" : [
{
"lang" : "eng",
"value" : "MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306"
}
]
}
]
},
"references" : {
"reference_data" : [
{
"url" : "https://ics-cert.us-cert.gov/advisories/ICSA-18-263-01"
}
]
}