"-Synchronized-Data."

This commit is contained in:
CVE Team 2020-09-11 14:01:35 +00:00
parent dd5db37e84
commit ad49a97d9d
No known key found for this signature in database
GPG Key ID: 5708902F06FEF743
9 changed files with 467 additions and 30 deletions

View File

@ -4,14 +4,58 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-11991",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "security@apache.org",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "Apache Cocoon",
"version": {
"version_data": [
{
"version_value": "Apache Cocoon 2.1.0 to 2.1.12"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Information Disclosure"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://lists.apache.org/thread.html/r77add973ea521185e1a90aca00ba9dae7caa8d8b944d92421702bb54%40%3Cusers.cocoon.apache.org%3E",
"url": "https://lists.apache.org/thread.html/r77add973ea521185e1a90aca00ba9dae7caa8d8b944d92421702bb54%40%3Cusers.cocoon.apache.org%3E"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "When using the StreamGenerator, the code parse a user-provided XML. A specially crafted XML, including external system entities, could be used to access any file on the server system."
}
]
}

View File

@ -4,14 +4,58 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-14096",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "security@xiaomi.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "Xiaomi AI speaker",
"version": {
"version_data": [
{
"version_value": "Rom version<1.59.6,fixed:Upgrade ROM Version =1.59.6"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Memory overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://privacy.mi.com/trust#/security/vulnerability-management/vulnerability-announcement/detail?id=19&locale=en",
"url": "https://privacy.mi.com/trust#/security/vulnerability-management/vulnerability-announcement/detail?id=19&locale=en"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Memory overflow in Xiaomi AI speaker Rom version <1.59.6 can happen when the speaker verifying a malicious firmware during OTA process."
}
]
}

View File

@ -4,14 +4,58 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-14100",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "security@xiaomi.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "Xiaomi router R3600",
"version": {
"version_data": [
{
"version_value": "ROM version<1.0.66,fixed:Upgrade ROM Version =1.0.66"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote code execution"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://privacy.mi.com/trust#/security/vulnerability-management/vulnerability-announcement/detail?id=20&locale=en",
"url": "https://privacy.mi.com/trust#/security/vulnerability-management/vulnerability-announcement/detail?id=20&locale=en"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "In Xiaomi router R3600 ROM version<1.0.66, filters in the set_WAN6 interface can be bypassed, causing remote code execution. The router administrator can gain root access from this vulnerability."
}
]
}

View File

@ -1,17 +1,66 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-15802",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ID": "CVE-2020-15802",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Devices supporting Bluetooth before 5.1 may allow man-in-the-middle attacks. Cross Transport Key Derivation in Bluetooth Core Specification v4.2 and v5.0 may permit an unauthenticated user to establish a bonding with one transport, either LE or BR/EDR, and replace a bonding already established on the opposing transport, BR/EDR or LE, potentially overwriting an authenticated key with an unauthenticated key, or a key with greater entropy with one with less."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"url": "https://www.kb.cert.org/vuls/id/589825",
"refsource": "MISC",
"name": "https://www.kb.cert.org/vuls/id/589825"
},
{
"refsource": "MISC",
"name": "https://gizmodo.com/bluetooth-unveils-its-latest-security-issue-with-no-se-1845013709",
"url": "https://gizmodo.com/bluetooth-unveils-its-latest-security-issue-with-no-se-1845013709"
}
]
}

View File

@ -4,14 +4,58 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-16212",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "ics-cert@hq.dhs.gov",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "Philips Patient Information Center iX (PICiX), PerformanceBridge Focal Point, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90, IntelliVue X3 and X2.",
"version": {
"version_data": [
{
"version_value": "Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior."
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "EXPOSURE OF RESOURCE TO WRONG SPHERE CWE-668"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01",
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could allow an attacker with physical access to escape the restricted environment with limited privileges."
}
]
}

View File

@ -4,14 +4,58 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-16216",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "ics-cert@hq.dhs.gov",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "Philips Patient Information Center iX (PICiX), PerformanceBridge Focal Point, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90, IntelliVue X3 and X2.",
"version": {
"version_data": [
{
"version_value": "Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior."
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "IMPROPER INPUT VALIDATION CWE-20"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01",
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart."
}
]
}

View File

@ -4,14 +4,58 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-16220",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "ics-cert@hq.dhs.gov",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "Philips Patient Information Center iX (PICiX), PerformanceBridge Focal Point, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90, IntelliVue X3 and X2.",
"version": {
"version_data": [
{
"version_value": "Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior."
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "IMPROPER VALIDATION OF SYNTACTIC CORRECTNESS OF INPUT CWE-1286"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01",
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it does not validate or incorrectly validates that the input complies with the syntax, causing the certificate enrollment service to crash. It does not impact monitoring but prevents new devices from enrolling."
}
]
}

View File

@ -4,14 +4,58 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-16224",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "ics-cert@hq.dhs.gov",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "Philips Patient Information Center iX (PICiX), PerformanceBridge Focal Point, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90, IntelliVue X3 and X2.",
"version": {
"version_data": [
{
"version_value": "Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior."
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "IMPROPER HANDLING OF LENGTH PARAMETER INCONSISTENCY CWE-130"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01",
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data, causing the application on the surveillance station to restart."
}
]
}

View File

@ -4,14 +4,94 @@
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2020-9239",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "psirt@huawei.com",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "n/a",
"product": {
"product_data": [
{
"product_name": "BLA-A09;BLA-TL00B;Berkeley-L09;Duke-L09;HUAWEI P20;HUAWEI P20 Pro;Jimmy-AL00A;LON-L29D;NEO-AL00D;Stanford-AL00;Toronto-AL00;Toronto-AL00A;Toronto-TL10",
"version": {
"version_data": [
{
"version_value": "8.0.0.123(C212),Versions earlier than 8.0.0.123(C567),Versions earlier than 8.0.0.123(C797)"
},
{
"version_value": "Versions earlier than 8.1.0.326(C01)"
},
{
"version_value": "Versions earlier than 8.0.0.163(C10),Versions earlier than 8.0.0.163(C432),Versions earlier than 8.0.0.163(C636),Versions earlier than 8.0.0.172(C10)"
},
{
"version_value": "Duke-L09C10B187,Duke-L09C432B189,Duke-L09C636B189"
},
{
"version_value": "Versions earlier than 8.0.1.16(C00)"
},
{
"version_value": "Versions earlier than 8.1.0.152(C00)"
},
{
"version_value": "Versions earlier than Jimmy-AL00AC00B172"
},
{
"version_value": "LON-L29DC721B192"
},
{
"version_value": "Versions earlier than 8.1.0.172(C786)"
},
{
"version_value": "Stanford-AL00C00B123"
},
{
"version_value": "Versions earlier than Toronto-AL00AC00B225"
},
{
"version_value": "Versions earlier than Toronto-AL00AC00B225"
},
{
"version_value": "Versions earlier than Toronto-TL10C01B225"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Information Leak"
}
]
}
]
},
"references": {
"reference_data": [
{
"refsource": "MISC",
"name": "https://www.huawei.com/en/psirt/security-advisories/huawei-sa-20200909-04-smartphone-en",
"url": "https://www.huawei.com/en/psirt/security-advisories/huawei-sa-20200909-04-smartphone-en"
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Huawei smartphones BLA-A09 versions 8.0.0.123(C212),versions earlier than 8.0.0.123(C567),versions earlier than 8.0.0.123(C797);BLA-TL00B versions earlier than 8.1.0.326(C01);Berkeley-L09 versions earlier than 8.0.0.163(C10),versions earlier than 8.0.0.163(C432),Versions earlier than 8.0.0.163(C636),Versions earlier than 8.0.0.172(C10);Duke-L09 versions Duke-L09C10B187, versions Duke-L09C432B189, versions Duke-L09C636B189;HUAWEI P20 versions earlier than 8.0.1.16(C00);HUAWEI P20 Pro versions earlier than 8.1.0.152(C00);Jimmy-AL00A versions earlier than Jimmy-AL00AC00B172;LON-L29D versions LON-L29DC721B192;NEO-AL00D versions earlier than 8.1.0.172(C786);Stanford-AL00 versions Stanford-AL00C00B123;Toronto-AL00 versions earlier than Toronto-AL00AC00B225;Toronto-AL00A versions earlier than Toronto-AL00AC00B225;Toronto-TL10 versions earlier than Toronto-TL10C01B225 have an information vulnerability. A module has a design error that is lack of control of input. Attackers can exploit this vulnerab"
}
]
}