"-Synchronized-Data."

This commit is contained in:
CVE Team 2023-09-14 11:00:33 +00:00
parent 5287e28e19
commit ad7f401714
No known key found for this signature in database
GPG Key ID: E3252B3D49582C98
2 changed files with 131 additions and 8 deletions

View File

@ -1,17 +1,73 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38557",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "productcert@siemens.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A vulnerability has been identified in Spectrum Power 7 (All versions < V23Q3). The affected product assigns improper access rights to the update script. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-732: Incorrect Permission Assignment for Critical Resource",
"cweId": "CWE-732"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Siemens",
"product": {
"product_data": [
{
"product_name": "Spectrum Power 7",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions < V23Q3"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-357182.pdf",
"refsource": "MISC",
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-357182.pdf"
}
]
},
"impact": {
"cvss": [
{
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"baseScore": 8.2,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,84 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38558",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "productcert@siemens.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A vulnerability has been identified in SIMATIC PCS neo (Administration Console) V4.0 (All versions), SIMATIC PCS neo (Administration Console) V4.0 Update 1 (All versions). The affected application leaks Windows admin credentials. An attacker with local access to the Administration Console could get the credentials, and impersonate the admin user, thereby gaining admin access to other Windows systems."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-538: Insertion of Sensitive Information into Externally-Accessible File or Directory",
"cweId": "CWE-538"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Siemens",
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS neo (Administration Console) V4.0",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS neo (Administration Console) V4.0 Update 1",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646240.pdf",
"refsource": "MISC",
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-646240.pdf"
}
]
},
"impact": {
"cvss": [
{
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"baseScore": 5.5,
"baseSeverity": "MEDIUM"
}
]
}