mirror of
https://github.com/CVEProject/cvelist.git
synced 2025-05-06 18:53:08 +00:00
"-Synchronized-Data."
This commit is contained in:
parent
5287e28e19
commit
ad7f401714
@ -1,17 +1,73 @@
|
||||
{
|
||||
"data_version": "4.0",
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2023-38557",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ASSIGNER": "productcert@siemens.com",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "A vulnerability has been identified in Spectrum Power 7 (All versions < V23Q3). The affected product assigns improper access rights to the update script. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-732: Incorrect Permission Assignment for Critical Resource",
|
||||
"cweId": "CWE-732"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"vendor_name": "Siemens",
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "Spectrum Power 7",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_value": "All versions < V23Q3"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-357182.pdf",
|
||||
"refsource": "MISC",
|
||||
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-357182.pdf"
|
||||
}
|
||||
]
|
||||
},
|
||||
"impact": {
|
||||
"cvss": [
|
||||
{
|
||||
"version": "3.1",
|
||||
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
|
||||
"baseScore": 8.2,
|
||||
"baseSeverity": "HIGH"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,84 @@
|
||||
{
|
||||
"data_version": "4.0",
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2023-38558",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ASSIGNER": "productcert@siemens.com",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "A vulnerability has been identified in SIMATIC PCS neo (Administration Console) V4.0 (All versions), SIMATIC PCS neo (Administration Console) V4.0 Update 1 (All versions). The affected application leaks Windows admin credentials. An attacker with local access to the Administration Console could get the credentials, and impersonate the admin user, thereby gaining admin access to other Windows systems."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CWE-538: Insertion of Sensitive Information into Externally-Accessible File or Directory",
|
||||
"cweId": "CWE-538"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"vendor_name": "Siemens",
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "SIMATIC PCS neo (Administration Console) V4.0",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_value": "All versions"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"product_name": "SIMATIC PCS neo (Administration Console) V4.0 Update 1",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_affected": "=",
|
||||
"version_value": "All versions"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646240.pdf",
|
||||
"refsource": "MISC",
|
||||
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-646240.pdf"
|
||||
}
|
||||
]
|
||||
},
|
||||
"impact": {
|
||||
"cvss": [
|
||||
{
|
||||
"version": "3.1",
|
||||
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
|
||||
"baseScore": 5.5,
|
||||
"baseSeverity": "MEDIUM"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
Loading…