From bf5470a126388702f9a09237b365001bb839b57f Mon Sep 17 00:00:00 2001 From: CVE Team Date: Fri, 7 Feb 2025 18:00:33 +0000 Subject: [PATCH] "-Synchronized-Data." --- 2022/26xxx/CVE-2022-26388.json | 153 ++++++++++++++++++++++++++++++- 2022/26xxx/CVE-2022-26389.json | 160 ++++++++++++++++++++++++++++++++- 2025/1xxx/CVE-2025-1119.json | 18 ++++ 2025/1xxx/CVE-2025-1120.json | 18 ++++ 4 files changed, 341 insertions(+), 8 deletions(-) create mode 100644 2025/1xxx/CVE-2025-1119.json create mode 100644 2025/1xxx/CVE-2025-1120.json diff --git a/2022/26xxx/CVE-2022-26388.json b/2022/26xxx/CVE-2022-26388.json index 9199c63d6d3..8fdf2166ec3 100644 --- a/2022/26xxx/CVE-2022-26388.json +++ b/2022/26xxx/CVE-2022-26388.json @@ -1,17 +1,162 @@ { + "data_version": "4.0", "data_type": "CVE", "data_format": "MITRE", - "data_version": "4.0", "CVE_data_meta": { "ID": "CVE-2022-26388", - "ASSIGNER": "cve@mitre.org", - "STATE": "RESERVED" + "ASSIGNER": "productsecurity@baxter.com", + "STATE": "PUBLIC" }, "description": { "description_data": [ { "lang": "eng", - "value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided." + "value": "A use of hard-coded password vulnerability may allow authentication abuse.This issue affects ELI 380 Resting Electrocardiograph: \n\nVersions 2.6.0 and prior; ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph:\n\nVersions 2.3.1 and prior; ELI 250c/BUR 250c Resting Electrocardiograph:\n\nVersions 2.1.2 and prior; ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: \n\nVersions 2.2.0 and prior." + } + ] + }, + "problemtype": { + "problemtype_data": [ + { + "description": [ + { + "lang": "eng", + "value": "CWE-259 Use of Hard-Coded Password", + "cweId": "CWE-259" + } + ] + } + ] + }, + "affects": { + "vendor": { + "vendor_data": [ + { + "vendor_name": "Welch Allyn", + "product": { + "product_data": [ + { + "product_name": "ELI 380 Resting Electrocardiograph", + "version": { + "version_data": [ + { + "version_affected": "<=", + "version_name": "0", + "version_value": "2.6.0" + } + ] + } + }, + { + "product_name": "ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph", + "version": { + "version_data": [ + { + "version_affected": "<=", + "version_name": "0", + "version_value": "2.3.1" + } + ] + } + }, + { + "product_name": "ELI 250c/BUR 250c Resting Electrocardiograph", + "version": { + "version_data": [ + { + "version_affected": "<=", + "version_name": "0", + "version_value": "2.1.2" + } + ] + } + }, + { + "product_name": "ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph", + "version": { + "version_data": [ + { + "version_affected": "<=", + "version_name": "0", + "version_value": "2.2.0" + } + ] + } + } + ] + } + } + ] + } + }, + "references": { + "reference_data": [ + { + "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-22-167-01", + "refsource": "MISC", + "name": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-22-167-01" + }, + { + "url": "https://hillrom.com/en/responsible-disclosures/", + "refsource": "MISC", + "name": "https://hillrom.com/en/responsible-disclosures/" + } + ] + }, + "generator": { + "engine": "Vulnogram 0.2.0" + }, + "source": { + "advisory": "ICSMA-22-167-01", + "discovery": "EXTERNAL" + }, + "work_around": [ + { + "lang": "en", + "supportingMedia": [ + { + "base64": false, + "type": "text/html", + "value": "

Hillrom recommends the following workarounds to help reduce risk:

\n\n\n
" + } + ], + "value": "Hillrom recommends the following workarounds to help reduce risk:\n\n\n\n * Apply proper network and physical security controls.\n\n * Ensure a unique encryption key is configured for ELI Link and Cardiograph.\n\n * Where possible, use a firewall to prevent communication on Port 21 \nFTP service, Port 22 SSH (Secure Shell Connection), and Port 23 Telnet \nservice." + } + ], + "solution": [ + { + "lang": "en", + "supportingMedia": [ + { + "base64": false, + "type": "text/html", + "value": "

Hillrom has released software updates for all impacted devices to \naddress these vulnerabilities. New product versions that mitigate these \nvulnerabilities are available as follows:

\n\n\n\nHillrom recommends users upgrade to the latest product versions. \nInformation on how to update these products can be found on the Hillrom disclosure page.\n\n
" + } + ], + "value": "Hillrom has released software updates for all impacted devices to \naddress these vulnerabilities. New product versions that mitigate these \nvulnerabilities are available as follows:\n\n\n\n * Welch Allyn ELI 380 Resting Electrocardiograph: available Q4 2023\n\n * Welch Allyn ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph: available May 2022\n\n * Welch Allyn ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: available Q4 2023\n\n\n\n\n\n\nHillrom recommends users upgrade to the latest product versions. \nInformation on how to update these products can be found on the Hillrom disclosure page https://hillrom.com/en/responsible-disclosures/ ." + } + ], + "credits": [ + { + "lang": "en", + "value": "An anonymous user reported these vulnerabilities to Hillrom." + } + ], + "impact": { + "cvss": [ + { + "attackComplexity": "LOW", + "attackVector": "PHYSICAL", + "availabilityImpact": "LOW", + "baseScore": 6.4, + "baseSeverity": "MEDIUM", + "confidentialityImpact": "HIGH", + "integrityImpact": "HIGH", + "privilegesRequired": "NONE", + "scope": "UNCHANGED", + "userInteraction": "NONE", + "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L", + "version": "3.1" } ] } diff --git a/2022/26xxx/CVE-2022-26389.json b/2022/26xxx/CVE-2022-26389.json index 7d161ea2586..582c269b759 100644 --- a/2022/26xxx/CVE-2022-26389.json +++ b/2022/26xxx/CVE-2022-26389.json @@ -1,17 +1,169 @@ { + "data_version": "4.0", "data_type": "CVE", "data_format": "MITRE", - "data_version": "4.0", "CVE_data_meta": { "ID": "CVE-2022-26389", - "ASSIGNER": "cve@mitre.org", - "STATE": "RESERVED" + "ASSIGNER": "productsecurity@baxter.com", + "STATE": "PUBLIC" }, "description": { "description_data": [ { "lang": "eng", - "value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided." + "value": "An improper access control vulnerability may allow privilege escalation.This issue affects:\u00a0\n\n * ELI 380 Resting Electrocardiograph:\n\nVersions 2.6.0 and prior;\u00a0\n * ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph:\n\nVersions 2.3.1 and prior;\u00a0\n * ELI 250c/BUR 250c Resting Electrocardiograph:\u00a0Versions 2.1.2 and prior;\u00a0\n * ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: \n\nVersions 2.2.0 and prior." + } + ] + }, + "problemtype": { + "problemtype_data": [ + { + "description": [ + { + "lang": "eng", + "value": "CWE-284 Improper Access Control", + "cweId": "CWE-284" + } + ] + } + ] + }, + "affects": { + "vendor": { + "vendor_data": [ + { + "vendor_name": "Baxter/ Hillrom", + "product": { + "product_data": [ + { + "product_name": "ELI 380 Resting Electrocardiograph", + "version": { + "version_data": [ + { + "version_affected": "<=", + "version_name": "0", + "version_value": "2.6.0" + } + ] + } + } + ] + } + }, + { + "vendor_name": "Welch Allyn", + "product": { + "product_data": [ + { + "product_name": "ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph", + "version": { + "version_data": [ + { + "version_affected": "<=", + "version_name": "0", + "version_value": "2.3.1" + } + ] + } + }, + { + "product_name": "ELI 250c/BUR 250c Resting Electrocardiograph", + "version": { + "version_data": [ + { + "version_affected": "<=", + "version_name": "0", + "version_value": "2.1.2" + } + ] + } + }, + { + "product_name": "ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph", + "version": { + "version_data": [ + { + "version_affected": "<=", + "version_name": "0", + "version_value": "2.2.0" + } + ] + } + } + ] + } + } + ] + } + }, + "references": { + "reference_data": [ + { + "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-22-167-01", + "refsource": "MISC", + "name": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-22-167-01" + }, + { + "url": "https://hillrom.com/en/responsible-disclosures/", + "refsource": "MISC", + "name": "https://hillrom.com/en/responsible-disclosures/" + } + ] + }, + "generator": { + "engine": "Vulnogram 0.2.0" + }, + "source": { + "advisory": "ICSMA-22-167-01", + "discovery": "EXTERNAL" + }, + "work_around": [ + { + "lang": "en", + "supportingMedia": [ + { + "base64": false, + "type": "text/html", + "value": "

Hillrom recommends the following workarounds to help reduce risk:

\n\n\n
" + } + ], + "value": "Hillrom recommends the following workarounds to help reduce risk:\n\n\n\n * Apply proper network and physical security controls.\n\n * Ensure a unique encryption key is configured for ELI Link and Cardiograph.\n\n * Where possible, use a firewall to prevent communication on Port 21 \nFTP service, Port 22 SSH (Secure Shell Connection), and Port 23 Telnet \nservice." + } + ], + "solution": [ + { + "lang": "en", + "supportingMedia": [ + { + "base64": false, + "type": "text/html", + "value": "

Hillrom has released software updates for all impacted devices to \naddress these vulnerabilities. New product versions that mitigate these \nvulnerabilities are available as follows:

\n\n

Hillrom recommends users upgrade to the latest product versions. \nInformation on how to update these products can be found on the Hillrom disclosure page

.\n\n
" + } + ], + "value": "Hillrom has released software updates for all impacted devices to \naddress these vulnerabilities. New product versions that mitigate these \nvulnerabilities are available as follows:\n\n\n\n * Welch Allyn ELI 380 Resting Electrocardiograph: available Q4 2023\n\n * Welch Allyn ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph: available May 2022\n\n * Welch Allyn ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: available Q4 2023\n\n\n\n\nHillrom recommends users upgrade to the latest product versions. \nInformation on how to update these products can be found on the Hillrom disclosure page https://hillrom.com/en/responsible-disclosures/ \n\n." + } + ], + "credits": [ + { + "lang": "en", + "value": "An anonymous user reported these vulnerabilities to Hillrom." + } + ], + "impact": { + "cvss": [ + { + "attackComplexity": "HIGH", + "attackVector": "NETWORK", + "availabilityImpact": "HIGH", + "baseScore": 7.7, + "baseSeverity": "HIGH", + "confidentialityImpact": "LOW", + "integrityImpact": "LOW", + "privilegesRequired": "LOW", + "scope": "CHANGED", + "userInteraction": "NONE", + "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:H", + "version": "3.1" } ] } diff --git a/2025/1xxx/CVE-2025-1119.json b/2025/1xxx/CVE-2025-1119.json new file mode 100644 index 00000000000..38acbf2312d --- /dev/null +++ b/2025/1xxx/CVE-2025-1119.json @@ -0,0 +1,18 @@ +{ + "data_type": "CVE", + "data_format": "MITRE", + "data_version": "4.0", + "CVE_data_meta": { + "ID": "CVE-2025-1119", + "ASSIGNER": "cve@mitre.org", + "STATE": "RESERVED" + }, + "description": { + "description_data": [ + { + "lang": "eng", + "value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided." + } + ] + } +} \ No newline at end of file diff --git a/2025/1xxx/CVE-2025-1120.json b/2025/1xxx/CVE-2025-1120.json new file mode 100644 index 00000000000..b7b40ff0cc2 --- /dev/null +++ b/2025/1xxx/CVE-2025-1120.json @@ -0,0 +1,18 @@ +{ + "data_type": "CVE", + "data_format": "MITRE", + "data_version": "4.0", + "CVE_data_meta": { + "ID": "CVE-2025-1120", + "ASSIGNER": "cve@mitre.org", + "STATE": "RESERVED" + }, + "description": { + "description_data": [ + { + "lang": "eng", + "value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided." + } + ] + } +} \ No newline at end of file