mirror of
https://github.com/CVEProject/cvelist.git
synced 2025-06-21 05:40:25 +00:00
"-Synchronized-Data."
This commit is contained in:
parent
4bbc1db49c
commit
c0f77ca9c7
@ -2,7 +2,30 @@
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"ID": "CVE-2018-17765",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "n/a",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
@ -11,7 +34,43 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Ingenico Telium 2 POS terminals have undeclared TRACE protocol commands. This is fixed in Telium 2 SDK v9.32.03 patch N."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://ingenico.us/smart-terminals/telium2",
|
||||
"refsource": "MISC",
|
||||
"name": "https://ingenico.us/smart-terminals/telium2"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://www.securingpayments.com/2020/08/are-happy-to-announce-that-ingenico-has.html",
|
||||
"url": "https://www.securingpayments.com/2020/08/are-happy-to-announce-that-ingenico-has.html"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://youtu.be/gtbS3Gr264w",
|
||||
"url": "https://youtu.be/gtbS3Gr264w"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://youtu.be/oyUD7RDJsJs",
|
||||
"url": "https://youtu.be/oyUD7RDJsJs"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -2,7 +2,30 @@
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"ID": "CVE-2018-17766",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "n/a",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
@ -11,7 +34,43 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Ingenico Telium 2 POS Telium2 OS allow bypass of file-reading restrictions via the NTPT3 protocol. This is fixed in Telium 2 SDK v9.32.03 patch N."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://ingenico.us/smart-terminals/telium2",
|
||||
"refsource": "MISC",
|
||||
"name": "https://ingenico.us/smart-terminals/telium2"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://www.securingpayments.com/2020/08/are-happy-to-announce-that-ingenico-has.html",
|
||||
"url": "https://www.securingpayments.com/2020/08/are-happy-to-announce-that-ingenico-has.html"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://youtu.be/gtbS3Gr264w",
|
||||
"url": "https://youtu.be/gtbS3Gr264w"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://youtu.be/oyUD7RDJsJs",
|
||||
"url": "https://youtu.be/oyUD7RDJsJs"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -2,7 +2,30 @@
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"ID": "CVE-2018-17767",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "n/a",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
@ -11,7 +34,43 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Ingenico Telium 2 POS terminals have hardcoded PPP credentials. This is fixed in Telium 2 SDK v9.32.03 patch N."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://ingenico.us/smart-terminals/telium2",
|
||||
"refsource": "MISC",
|
||||
"name": "https://ingenico.us/smart-terminals/telium2"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://www.securingpayments.com/2020/08/are-happy-to-announce-that-ingenico-has.html",
|
||||
"url": "https://www.securingpayments.com/2020/08/are-happy-to-announce-that-ingenico-has.html"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://youtu.be/gtbS3Gr264w",
|
||||
"url": "https://youtu.be/gtbS3Gr264w"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://youtu.be/oyUD7RDJsJs",
|
||||
"url": "https://youtu.be/oyUD7RDJsJs"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -2,7 +2,30 @@
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"ID": "CVE-2018-17768",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "n/a",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
@ -11,7 +34,43 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Ingenico Telium 2 POS terminals have an insecure TRACE protocol. This is fixed in Telium 2 SDK v9.32.03 patch N."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://ingenico.us/smart-terminals/telium2",
|
||||
"refsource": "MISC",
|
||||
"name": "https://ingenico.us/smart-terminals/telium2"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://www.securingpayments.com/2020/08/are-happy-to-announce-that-ingenico-has.html",
|
||||
"url": "https://www.securingpayments.com/2020/08/are-happy-to-announce-that-ingenico-has.html"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://youtu.be/gtbS3Gr264w",
|
||||
"url": "https://youtu.be/gtbS3Gr264w"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://youtu.be/oyUD7RDJsJs",
|
||||
"url": "https://youtu.be/oyUD7RDJsJs"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -2,7 +2,30 @@
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"ID": "CVE-2018-17769",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "n/a",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
@ -11,7 +34,43 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Ingenico Telium 2 POS terminals have a buffer overflow via the 0x26 command of the NTPT3 protocol. This is fixed in Telium 2 SDK v9.32.03 patch N."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://ingenico.us/smart-terminals/telium2",
|
||||
"refsource": "MISC",
|
||||
"name": "https://ingenico.us/smart-terminals/telium2"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://www.securingpayments.com/2020/08/are-happy-to-announce-that-ingenico-has.html",
|
||||
"url": "https://www.securingpayments.com/2020/08/are-happy-to-announce-that-ingenico-has.html"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://youtu.be/gtbS3Gr264w",
|
||||
"url": "https://youtu.be/gtbS3Gr264w"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://youtu.be/oyUD7RDJsJs",
|
||||
"url": "https://youtu.be/oyUD7RDJsJs"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -2,7 +2,30 @@
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"ID": "CVE-2018-17770",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "n/a",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
@ -11,7 +34,43 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Ingenico Telium 2 POS terminals have a buffer overflow via the RemotePutFile command of the NTPT3 protocol. This is fixed in Telium 2 SDK v9.32.03 patch N."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://ingenico.us/smart-terminals/telium2",
|
||||
"refsource": "MISC",
|
||||
"name": "https://ingenico.us/smart-terminals/telium2"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://www.securingpayments.com/2020/08/are-happy-to-announce-that-ingenico-has.html",
|
||||
"url": "https://www.securingpayments.com/2020/08/are-happy-to-announce-that-ingenico-has.html"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://youtu.be/gtbS3Gr264w",
|
||||
"url": "https://youtu.be/gtbS3Gr264w"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://youtu.be/oyUD7RDJsJs",
|
||||
"url": "https://youtu.be/oyUD7RDJsJs"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -2,7 +2,30 @@
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"ID": "CVE-2018-17771",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "n/a",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
@ -11,7 +34,43 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Ingenico Telium 2 POS terminals have hardcoded FTP credentials. This is fixed in Telium 2 SDK v9.32.03 patch N."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://ingenico.us/smart-terminals/telium2",
|
||||
"refsource": "MISC",
|
||||
"name": "https://ingenico.us/smart-terminals/telium2"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://www.securingpayments.com/2020/08/are-happy-to-announce-that-ingenico-has.html",
|
||||
"url": "https://www.securingpayments.com/2020/08/are-happy-to-announce-that-ingenico-has.html"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://youtu.be/gtbS3Gr264w",
|
||||
"url": "https://youtu.be/gtbS3Gr264w"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://youtu.be/oyUD7RDJsJs",
|
||||
"url": "https://youtu.be/oyUD7RDJsJs"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -2,7 +2,30 @@
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"ID": "CVE-2018-17772",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "n/a",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
@ -11,7 +34,43 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Ingenico Telium 2 POS terminals allow arbitrary code execution via the TRACE protocol. This is fixed in Telium 2 SDK v9.32.03 patch N."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://ingenico.us/smart-terminals/telium2",
|
||||
"refsource": "MISC",
|
||||
"name": "https://ingenico.us/smart-terminals/telium2"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://www.securingpayments.com/2020/08/are-happy-to-announce-that-ingenico-has.html",
|
||||
"url": "https://www.securingpayments.com/2020/08/are-happy-to-announce-that-ingenico-has.html"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://youtu.be/gtbS3Gr264w",
|
||||
"url": "https://youtu.be/gtbS3Gr264w"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://youtu.be/oyUD7RDJsJs",
|
||||
"url": "https://youtu.be/oyUD7RDJsJs"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -2,7 +2,30 @@
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"ID": "CVE-2018-17773",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "n/a",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
@ -11,7 +34,43 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Ingenico Telium 2 POS terminals have a buffer overflow via SOCKET_TASK in the NTPT3 protocol. This is fixed in Telium 2 SDK v9.32.03 patch N."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://ingenico.us/smart-terminals/telium2",
|
||||
"refsource": "MISC",
|
||||
"name": "https://ingenico.us/smart-terminals/telium2"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://www.securingpayments.com/2020/08/are-happy-to-announce-that-ingenico-has.html",
|
||||
"url": "https://www.securingpayments.com/2020/08/are-happy-to-announce-that-ingenico-has.html"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://youtu.be/gtbS3Gr264w",
|
||||
"url": "https://youtu.be/gtbS3Gr264w"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://youtu.be/oyUD7RDJsJs",
|
||||
"url": "https://youtu.be/oyUD7RDJsJs"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -2,7 +2,30 @@
|
||||
"CVE_data_meta": {
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"ID": "CVE-2018-17774",
|
||||
"STATE": "RESERVED"
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "n/a",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
@ -11,7 +34,43 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Ingenico Telium 2 POS terminals have an insecure NTPT3 protocol. This is fixed in Telium 2 SDK v9.32.03 patch N."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://ingenico.us/smart-terminals/telium2",
|
||||
"refsource": "MISC",
|
||||
"name": "https://ingenico.us/smart-terminals/telium2"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://www.securingpayments.com/2020/08/are-happy-to-announce-that-ingenico-has.html",
|
||||
"url": "https://www.securingpayments.com/2020/08/are-happy-to-announce-that-ingenico-has.html"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://youtu.be/gtbS3Gr264w",
|
||||
"url": "https://youtu.be/gtbS3Gr264w"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://youtu.be/oyUD7RDJsJs",
|
||||
"url": "https://youtu.be/oyUD7RDJsJs"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -556,7 +556,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC CFU PA, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET200AL, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC ET200ecoPN (except 6ES7141-6BG00-0BB0, 6ES7141-6BH00-0BB0, 6ES7142-6BG00-0BB0, 6ES7142-6BR00-0BB0, 6ES7143-6BH00-0BB0, 6ES7146-6FF00-0AB0 and 6ES7148-6JD00-0AB0), SIMATIC ET200pro, SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (incl. SIPLUS variants), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants), SIMATIC HMI KTP Mobile Panels, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC PROFINET Driver, SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 PN Control Unit, SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl. Affected devices contain a vulnerability that allows an unauthenticated attacker\nto trigger a denial-of-service condition. The vulnerability can be triggered \nif a large amount of specially crafted UDP packets are sent to device.\n\nThe security vulnerability could be exploited by an attacker with network \naccess to the affected systems. Successful exploitation requires no system\nprivileges and no user interaction. An attacker could use the vulnerability\nto compromise availability of the device.\n\nAt the time of advisory publication no public exploitation of this security\nvulnerability was known.\n"
|
||||
"value": "A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC CFU PA, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET200AL, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants), SIMATIC ET200S (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN BA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC ET200ecoPN (except 6ES7141-6BG00-0BB0, 6ES7141-6BH00-0BB0, 6ES7142-6BG00-0BB0, 6ES7142-6BR00-0BB0, 6ES7143-6BH00-0BB0, 6ES7146-6FF00-0AB0 and 6ES7148-6JD00-0AB0), SIMATIC ET200pro, SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (incl. SIPLUS variants), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants), SIMATIC HMI KTP Mobile Panels, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC PROFINET Driver, SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 PN Control Unit, SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl. Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of specially crafted UDP packets are sent to device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -446,7 +446,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All Versions < V4.5), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All Versions < V4.6), PROFINET Driver for Controller (All Versions < V2.1), RUGGEDCOM RM1224 (All versions < V4.3), SCALANCE M-800 / S615 (All versions < V4.3), SCALANCE W700 IEEE 802.11n (All versions <= V6.0.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All Versions < V5.3), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions), SCALANCE XB-200, XC-200, XP-200, XF-200BA and XR-300WG (All Versions < V3.0), SCALANCE XM-400 switch family (All Versions < V6.0), SCALANCE XR-500 switch family (All Versions < V6.0), SIMATIC ET200AL IM 157-1 PN (All versions), SIMATIC ET200M IM153-4 PN IO HF (incl. SIPLUS variants) (All versions), SIMATIC ET200M IM153-4 PN IO ST (incl. SIPLUS variants) (All versions), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants) (All Versions < V4.2.0), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants) (All Versions < V4.1.0), SIMATIC ET200S (incl. SIPLUS variants) (All versions), SIMATIC ET200SP IM155-6 PN Basic (incl. SIPLUS variants) (All versions), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants) (All Versions < V3.3.1), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants) (All Versions < V4.1.0), SIMATIC ET200ecoPN (except 6ES7141-6BG00-0BB0, 6ES7141-6BH00-0BB0, 6ES7142-6BG00-0BB0, 6ES7142-6BR00-0BB0, 6ES7143-6BH00-0BB0, 6ES7146-6FF00-0AB0 and 6ES7148-6JD00-0AB0) (All versions), SIMATIC ET200pro, IM 154-3 PN HF (All versions), SIMATIC ET200pro, IM 154-4 PN HF (All versions), SIMATIC IPC Support, Package for VxWorks (All versions), SIMATIC MV400 family (All versions), SIMATIC NET CP 1616 and CP 1604 (All Versions < V2.8), SIMATIC NET CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 ERPC (All versions), SIMATIC NET CP 343-1 LEAN (incl. SIPLUS variants) (All versions), SIMATIC NET CP 443-1 (incl. SIPLUS variants) (All versions), SIMATIC NET CP 443-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC NET CP 443-1 OPC UA (All versions), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. SIPLUS NET variant) (All Versions), SIMATIC RF180C (All versions), SIMATIC RF182C (All versions), SIMATIC RF600 family (All versions < V3), SINAMICS DCP (All Versions < V1.3), SOFTNET-IE PNIO (All versions). Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit\ninternal resource allocation when multiple legitimate diagnostic package\nrequests are sent to the DCE-RPC interface.\nThis could lead to a denial of service condition due to lack of memory\nfor devices that include a vulnerable version of the stack.\n\nThe security vulnerability could be exploited by an attacker with network\naccess to an affected device. Successful exploitation requires no system\nprivileges and no user interaction. An attacker could use the vulnerability\nto compromise the availability of the device.\n"
|
||||
"value": "A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All Versions < V4.5), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All Versions < V4.6), PROFINET Driver for Controller (All Versions < V2.1), RUGGEDCOM RM1224 (All versions < V4.3), SCALANCE M-800 / S615 (All versions < V4.3), SCALANCE W700 IEEE 802.11n (All versions <= V6.0.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All Versions < V5.3), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions), SCALANCE XB-200, XC-200, XP-200, XF-200BA and XR-300WG (All Versions < V3.0), SCALANCE XM-400 switch family (All Versions < V6.0), SCALANCE XR-500 switch family (All Versions < V6.0), SIMATIC ET200AL IM 157-1 PN (All versions), SIMATIC ET200M IM153-4 PN IO HF (incl. SIPLUS variants) (All versions), SIMATIC ET200M IM153-4 PN IO ST (incl. SIPLUS variants) (All versions), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants) (All Versions < V4.2.0), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants) (All Versions < V4.1.0), SIMATIC ET200S (incl. SIPLUS variants) (All versions), SIMATIC ET200SP IM155-6 PN Basic (incl. SIPLUS variants) (All versions), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants) (All Versions < V3.3.1), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants) (All Versions < V4.1.0), SIMATIC ET200ecoPN (except 6ES7141-6BG00-0BB0, 6ES7141-6BH00-0BB0, 6ES7142-6BG00-0BB0, 6ES7142-6BR00-0BB0, 6ES7143-6BH00-0BB0, 6ES7146-6FF00-0AB0 and 6ES7148-6JD00-0AB0) (All versions), SIMATIC ET200pro, IM 154-3 PN HF (All versions), SIMATIC ET200pro, IM 154-4 PN HF (All versions), SIMATIC IPC Support, Package for VxWorks (All versions), SIMATIC MV400 family (All versions), SIMATIC NET CP 1616 and CP 1604 (All Versions < V2.8), SIMATIC NET CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 ERPC (All versions), SIMATIC NET CP 343-1 LEAN (incl. SIPLUS variants) (All versions), SIMATIC NET CP 443-1 (incl. SIPLUS variants) (All versions), SIMATIC NET CP 443-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC NET CP 443-1 OPC UA (All versions), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. SIPLUS NET variant) (All Versions), SIMATIC RF180C (All versions), SIMATIC RF182C (All versions), SIMATIC RF600 family (All versions < V3), SINAMICS DCP (All Versions < V1.3), SOFTNET-IE PNIO (All versions). Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device."
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -236,7 +236,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition.\nSuccessful exploitation requires no system privileges and no user interaction.\n"
|
||||
"value": "A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition. Successful exploitation requires no system privileges and no user interaction."
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -746,7 +746,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in RFID 181EIP, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (incl. SIPLUS variants), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F, SIMATIC IPC DiagMonitor, SIMATIC NET CP 1616 and CP 1604, SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants), SIMATIC NET CP 443-1 (incl. SIPLUS variants), SIMATIC NET CP 443-1 Advanced (incl. SIPLUS variants), SIMATIC NET CP 443-1 OPC UA, SIMATIC RF182C, SIMATIC RF185C, SIMATIC RF186C, SIMATIC RF188C, SIMATIC RF600 family, SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-PLCSIM Advanced, SIMATIC Teleservice Adapter IE Advanced, SIMATIC Teleservice Adapter IE Basic, SIMATIC Teleservice Adapter IE Standard, SIMATIC WinAC RTX (F) 2010, SIMATIC WinCC Runtime Advanced, SIMOCODE pro V EIP (incl. SIPLUS variants), SIMOCODE pro V PN (incl. SIPLUS variants), SINAMICS G130 V4.6 Control Unit, SINAMICS G130 V4.7 Control Unit, SINAMICS G130 V4.7 SP1 Control Unit, SINAMICS G130 V4.8 Control Unit, SINAMICS G130 V5.1 Control Unit, SINAMICS G130 V5.1 SP1 Control Unit, SINAMICS G150 V4.6 Control Unit, SINAMICS G150 V4.7 Control Unit, SINAMICS G150 V4.7 SP1 Control Unit, SINAMICS G150 V4.8 Control Unit, SINAMICS G150 V5.1 Control Unit, SINAMICS G150 V5.1 SP1 Control Unit, SINAMICS GH150 V4.7 (Control Unit), SINAMICS GH150 V4.8 (Control Unit), SINAMICS GL150 V4.7 (Control Unit), SINAMICS GL150 V4.8 (Control Unit), SINAMICS GM150 V4.7 (Control Unit), SINAMICS GM150 V4.8 (Control Unit), SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants), SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants), SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants), SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants), SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants), SINAMICS S150 V4.6 Control Unit, SINAMICS S150 V4.7 Control Unit, SINAMICS S150 V4.7 SP1 Control Unit, SINAMICS S150 V4.8 Control Unit, SINAMICS S150 V5.1 Control Unit, SINAMICS S150 V5.1 SP1 Control Unit, SINAMICS S210 V5.1 Control Unit, SINAMICS S210 V5.1 SP1 Control Unit, SINAMICS SL150 V4.7 (Control Unit), SINAMICS SL150 V4.8 (Control Unit), SINAMICS SM120 V4.7 (Control Unit), SINAMICS SM120 V4.8 (Control Unit), SINAMICS SM150 V4.8 (Control Unit), SITOP Manager, SITOP PSU8600, SITOP UPS1600 (incl. SIPLUS variants), TIM 1531 IRC (incl. SIPLUS NET variants). The webserver of the affected devices contains a vulnerability that may lead to\na denial-of-service condition. An attacker may cause a denial-of-service\nsituation which leads to a restart of the webserver of the affected device.\n\nThe security vulnerability could be exploited by an attacker with network\naccess to the affected systems. Successful exploitation requires no system\nprivileges and no user interaction. An attacker could use the vulnerability\nto compromise availability of the device.\n\nAt the time of advisory publication no public exploitation of this security\nvulnerability was known.\n"
|
||||
"value": "A vulnerability has been identified in RFID 181EIP, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (incl. SIPLUS variants), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F, SIMATIC IPC DiagMonitor, SIMATIC NET CP 1616 and CP 1604, SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants), SIMATIC NET CP 443-1 (incl. SIPLUS variants), SIMATIC NET CP 443-1 Advanced (incl. SIPLUS variants), SIMATIC NET CP 443-1 OPC UA, SIMATIC RF182C, SIMATIC RF185C, SIMATIC RF186C, SIMATIC RF188C, SIMATIC RF600 family, SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-PLCSIM Advanced, SIMATIC Teleservice Adapter IE Advanced, SIMATIC Teleservice Adapter IE Basic, SIMATIC Teleservice Adapter IE Standard, SIMATIC WinAC RTX (F) 2010, SIMATIC WinCC Runtime Advanced, SIMOCODE pro V EIP (incl. SIPLUS variants), SIMOCODE pro V PN (incl. SIPLUS variants), SINAMICS G130 V4.6 Control Unit, SINAMICS G130 V4.7 Control Unit, SINAMICS G130 V4.7 SP1 Control Unit, SINAMICS G130 V4.8 Control Unit, SINAMICS G130 V5.1 Control Unit, SINAMICS G130 V5.1 SP1 Control Unit, SINAMICS G150 V4.6 Control Unit, SINAMICS G150 V4.7 Control Unit, SINAMICS G150 V4.7 SP1 Control Unit, SINAMICS G150 V4.8 Control Unit, SINAMICS G150 V5.1 Control Unit, SINAMICS G150 V5.1 SP1 Control Unit, SINAMICS GH150 V4.7 (Control Unit), SINAMICS GH150 V4.8 (Control Unit), SINAMICS GL150 V4.7 (Control Unit), SINAMICS GL150 V4.8 (Control Unit), SINAMICS GM150 V4.7 (Control Unit), SINAMICS GM150 V4.8 (Control Unit), SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants), SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants), SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants), SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants), SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants), SINAMICS S150 V4.6 Control Unit, SINAMICS S150 V4.7 Control Unit, SINAMICS S150 V4.7 SP1 Control Unit, SINAMICS S150 V4.8 Control Unit, SINAMICS S150 V5.1 Control Unit, SINAMICS S150 V5.1 SP1 Control Unit, SINAMICS S210 V5.1 Control Unit, SINAMICS S210 V5.1 SP1 Control Unit, SINAMICS SL150 V4.7 (Control Unit), SINAMICS SL150 V4.8 (Control Unit), SINAMICS SM120 V4.7 (Control Unit), SINAMICS SM120 V4.8 (Control Unit), SINAMICS SM150 V4.8 (Control Unit), SITOP Manager, SITOP PSU8600, SITOP UPS1600 (incl. SIPLUS variants), TIM 1531 IRC (incl. SIPLUS NET variants). The webserver of the affected devices contains a vulnerability that may lead to a denial-of-service condition. An attacker may cause a denial-of-service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -46,15 +46,16 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). The start-stop scripts for the services of the affected application could allow a local attacker to include arbitrary commands that are executed when services are started or stopped interactively by system administrators.\n"
|
||||
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). The start-stop scripts for the services of the affected application could allow a local attacker to include arbitrary commands that are executed when services are started or stopped interactively by system administrators."
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-251935.pdf"
|
||||
"refsource": "MISC",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-251935.pdf",
|
||||
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-251935.pdf"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -46,15 +46,16 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). The directory of service executables of the affected application could allow a local attacker to include arbitrary commands that are executed with SYSTEM privileges when the system restarts.\n"
|
||||
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). The directory of service executables of the affected application could allow a local attacker to include arbitrary commands that are executed with SYSTEM privileges when the system restarts."
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-251935.pdf"
|
||||
"refsource": "MISC",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-251935.pdf",
|
||||
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-251935.pdf"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -46,15 +46,16 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). Multiple services of the affected application are executed with SYSTEM privileges while the call path is not quoted.\nThis could allow a local attacker to inject arbitrary commands that are execeuted instead of the legitimate service.\n"
|
||||
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). Multiple services of the affected application are executed with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to inject arbitrary commands that are execeuted instead of the legitimate service."
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-251935.pdf"
|
||||
"refsource": "MISC",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-251935.pdf",
|
||||
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-251935.pdf"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -46,15 +46,16 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in License Management Utility (LMU) (All versions < V2.4). The lmgrd service of the affected application is executed with local SYSTEM privileges\non the server while its configuration can be modified by local users.\n\nThe vulnerability could allow a local authenticated attacker to execute\narbitrary commands on the server with local SYSTEM privileges.\n"
|
||||
"value": "A vulnerability has been identified in License Management Utility (LMU) (All versions < V2.4). The lmgrd service of the affected application is executed with local SYSTEM privileges on the server while its configuration can be modified by local users. The vulnerability could allow a local authenticated attacker to execute arbitrary commands on the server with local SYSTEM privileges."
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-709003.pdf"
|
||||
"refsource": "MISC",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-709003.pdf",
|
||||
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-709003.pdf"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -88,6 +88,11 @@
|
||||
"refsource": "GENTOO",
|
||||
"name": "GLSA-202008-18",
|
||||
"url": "https://security.gentoo.org/glsa/202008-18"
|
||||
},
|
||||
{
|
||||
"refsource": "UBUNTU",
|
||||
"name": "USN-4487-1",
|
||||
"url": "https://usn.ubuntu.com/4487-1/"
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -46,15 +46,16 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP8). Insecure storage of sensitive information in the configuration files could allow the retrieval of user names.\n"
|
||||
"value": "A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP8). Insecure storage of sensitive information in the configuration files could allow the retrieval of user names."
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-568969.pdf"
|
||||
"refsource": "MISC",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-568969.pdf",
|
||||
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-568969.pdf"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -46,15 +46,16 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in Siveillance Video Client (All versions). In environments where Windows NTLM authentication is enabled the affected\nclient application transmits usernames to the server in cleartext.\n\nThis could allow an attacker in a privileged network position to obtain valid\nadminstrator login names and use this information to launch further attacks.\n"
|
||||
"value": "A vulnerability has been identified in Siveillance Video Client (All versions). In environments where Windows NTLM authentication is enabled the affected client application transmits usernames to the server in cleartext. This could allow an attacker in a privileged network position to obtain valid adminstrator login names and use this information to launch further attacks."
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-770698.pdf"
|
||||
"refsource": "MISC",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-770698.pdf",
|
||||
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-770698.pdf"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -76,15 +76,16 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions >= 14 and V < XX), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI Mobile Panels (All versions), SIMATIC HMI United Comfort Panels (All versions). Affected devices insufficiently block excessive authentication attempts.\n\nThis could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.\n"
|
||||
"value": "A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions >= 14 and V < XX), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI Mobile Panels (All versions), SIMATIC HMI United Comfort Panels (All versions). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack."
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf"
|
||||
"refsource": "MISC",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf",
|
||||
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -46,15 +46,16 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in SIMATIC HMI United Comfort Panels (All versions). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string.\n\nThis could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.\n"
|
||||
"value": "A vulnerability has been identified in SIMATIC HMI United Comfort Panels (All versions). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack."
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf"
|
||||
"refsource": "MISC",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf",
|
||||
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -46,15 +46,16 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in Polarion Subversion Webclient (All versions). The Polarion subversion web application does not filter user input in a way that prevents \nCross-Site Scripting. \n\nIf a user is enticed into passing specially crafted, \nmalicious input to the web client (e.g. by clicking on a malicious URL with embedded JavaScript), \nthen JavaScript code can be returned and may then be executed by the user\u2019s client. \n\nVarious actions could be triggered by running malicious JavaScript code.\n"
|
||||
"value": "A vulnerability has been identified in Polarion Subversion Webclient (All versions). The Polarion subversion web application does not filter user input in a way that prevents Cross-Site Scripting. If a user is enticed into passing specially crafted, malicious input to the web client (e.g. by clicking on a malicious URL with embedded JavaScript), then JavaScript code can be returned and may then be executed by the user\u2019s client. Various actions could be triggered by running malicious JavaScript code."
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-436520.pdf"
|
||||
"refsource": "MISC",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-436520.pdf",
|
||||
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-436520.pdf"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -46,15 +46,16 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in Polarion Subversion Webclient (All versions). The web interface could allow a Cross-Site Request Forgery (CSRF) attack\nif an unsuspecting user is tricked into accessing a malicious link.\n\nSuccessful exploitation requires user interaction by a legitimate user, who must be \nauthenticated to the web interface. A successful attack could allow an attacker to \ntrigger actions via the web interface that the legitimate user is allowed to perform. \nThis could allow the attacker to read or modify contents of the web application.\n"
|
||||
"value": "A vulnerability has been identified in Polarion Subversion Webclient (All versions). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user, who must be authenticated to the web interface. A successful attack could allow an attacker to trigger actions via the web interface that the legitimate user is allowed to perform. This could allow the attacker to read or modify contents of the web application."
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-436520.pdf"
|
||||
"refsource": "MISC",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-436520.pdf",
|
||||
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-436520.pdf"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -46,15 +46,16 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP8). If configured in an insecure manner, the web server might be susceptible to a directory listing attack. \n"
|
||||
"value": "A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP8). If configured in an insecure manner, the web server might be susceptible to a directory listing attack."
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-568969.pdf"
|
||||
"refsource": "MISC",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-568969.pdf",
|
||||
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-568969.pdf"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -56,15 +56,16 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 CPU family (incl. SIPLUS variants) (All versions). The authentication protocol between a client and a PLC via port 102/tcp (ISO-TSAP) insufficiently protects the transmitted password. This could allow an attacker that is able to intercept the network traffic to obtain valid PLC credentials.\n"
|
||||
"value": "A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 CPU family (incl. SIPLUS variants) (All versions). The authentication protocol between a client and a PLC via port 102/tcp (ISO-TSAP) insufficiently protects the transmitted password. This could allow an attacker that is able to intercept the network traffic to obtain valid PLC credentials."
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-381684.pdf"
|
||||
"refsource": "MISC",
|
||||
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-381684.pdf",
|
||||
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-381684.pdf"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,76 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2020-24379",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ID": "CVE-2020-24379",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "n/a",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "WebDAV implementation in Yaws web server versions 1.81 to 2.0.7 is vulnerable to XXE injection."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://github.com/erlyaws/yaws/commits/master",
|
||||
"refsource": "MISC",
|
||||
"name": "https://github.com/erlyaws/yaws/commits/master"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://packetstormsecurity.com/files/159106/Yaws-2.0.7-XML-Injection-Command-Injection.html",
|
||||
"url": "https://packetstormsecurity.com/files/159106/Yaws-2.0.7-XML-Injection-Command-Injection.html"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://vuln.be/post/yaws-xxe-and-shell-injections/",
|
||||
"url": "https://vuln.be/post/yaws-xxe-and-shell-injections/"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://github.com/vulnbe/poc-yaws-dav-xxe",
|
||||
"url": "https://github.com/vulnbe/poc-yaws-dav-xxe"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,76 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2020-24916",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ID": "CVE-2020-24916",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"description": {
|
||||
"description_data": [
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "n/a",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "CGI implementation in Yaws web server versions 1.81 to 2.0.7 is vulnerable to OS command injection."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://github.com/erlyaws/yaws/commits/master",
|
||||
"refsource": "MISC",
|
||||
"name": "https://github.com/erlyaws/yaws/commits/master"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://packetstormsecurity.com/files/159106/Yaws-2.0.7-XML-Injection-Command-Injection.html",
|
||||
"url": "https://packetstormsecurity.com/files/159106/Yaws-2.0.7-XML-Injection-Command-Injection.html"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://vuln.be/post/yaws-xxe-and-shell-injections/",
|
||||
"url": "https://vuln.be/post/yaws-xxe-and-shell-injections/"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"name": "https://github.com/vulnbe/poc-yaws-cgi-shell-injection",
|
||||
"url": "https://github.com/vulnbe/poc-yaws-cgi-shell-injection"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -69,7 +69,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A reflected cross-site scripting (XSS) vulnerability exists in the PAN-OS management web interface. A remote attacker able to convince an administrator with an active authenticated session on the firewall management interface to click on a crafted link to that management web interface could potentially execute arbitrary JavaScript code in the administrator's browser and perform administrative actions.\nThis issue impacts:\nPAN-OS 8.1 versions earlier than PAN-OS 8.1.16;\nPAN-OS 9.0 versions earlier than PAN-OS 9.0.9."
|
||||
"value": "A reflected cross-site scripting (XSS) vulnerability exists in the PAN-OS management web interface. A remote attacker able to convince an administrator with an active authenticated session on the firewall management interface to click on a crafted link to that management web interface could potentially execute arbitrary JavaScript code in the administrator's browser and perform administrative actions. This issue impacts: PAN-OS 8.1 versions earlier than PAN-OS 8.1.16; PAN-OS 9.0 versions earlier than PAN-OS 9.0.9."
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -91,16 +91,6 @@
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"url": "https://bugs.php.net/bug.php?id=79282",
|
||||
"name": "https://bugs.php.net/bug.php?id=79282"
|
||||
},
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"name": "https://security.netapp.com/advisory/ntap-20200403-0001/",
|
||||
"url": "https://security.netapp.com/advisory/ntap-20200403-0001/"
|
||||
},
|
||||
{
|
||||
"refsource": "MLIST",
|
||||
"name": "[debian-lts-announce] 20200426 [SECURITY] [DLA 2188-1] php5 security update",
|
||||
@ -130,6 +120,16 @@
|
||||
"refsource": "DEBIAN",
|
||||
"name": "DSA-4719",
|
||||
"url": "https://www.debian.org/security/2020/dsa-4719"
|
||||
},
|
||||
{
|
||||
"refsource": "MISC",
|
||||
"url": "https://bugs.php.net/bug.php?id=79282",
|
||||
"name": "https://bugs.php.net/bug.php?id=79282"
|
||||
},
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"name": "https://security.netapp.com/advisory/ntap-20200403-0001/",
|
||||
"url": "https://security.netapp.com/advisory/ntap-20200403-0001/"
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -98,8 +98,9 @@
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://bugs.php.net/bug.php?id=79797"
|
||||
"refsource": "MISC",
|
||||
"url": "https://bugs.php.net/bug.php?id=79797",
|
||||
"name": "https://bugs.php.net/bug.php?id=79797"
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -286,7 +286,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions), SIMATIC NET PC software (All versions V16 < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions), SIMATIC S7-1500 Software Controller (All versions), SIMATIC STEP 7 (All versions < V5.6 SP2 HF3), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions), SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC WinCC OA V3.16 (All versions < P018), SIMATIC WinCC OA V3.17 (All versions < P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER commissioning tool (All versions), SINAMICS Startdrive (All versions), SINEC NMS (All versions), SINEMA Server (All versions), SINUMERIK ONE virtual (All versions), SINUMERIK Operate (All versions). A component within the affected application regularly calls a helper binary with SYSTEM privileges while the call path is not quoted.\n"
|
||||
"value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions), SIMATIC NET PC software (All versions V16 < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions), SIMATIC S7-1500 Software Controller (All versions), SIMATIC STEP 7 (All versions < V5.6 SP2 HF3), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions), SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC WinCC OA V3.16 (All versions < P018), SIMATIC WinCC OA V3.17 (All versions < P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER commissioning tool (All versions), SINAMICS Startdrive (All versions), SINEC NMS (All versions), SINEMA Server (All versions), SINUMERIK ONE virtual (All versions), SINUMERIK Operate (All versions). A component within the affected application regularly calls a helper binary with SYSTEM privileges while the call path is not quoted."
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -156,7 +156,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions), Soft Starter ES (All versions). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted.\n"
|
||||
"value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions), Soft Starter ES (All versions). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted."
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -176,7 +176,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions), Soft Starter ES (All versions). Sending multiple specially crafted packets to the affected service could\ncause a partial remote Denial-of-Service, that would cause the service\nto restart itself.\n\nOn some cases the vulnerability could leak random information from the\nremote service.\n"
|
||||
"value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions), Soft Starter ES (All versions). Sending multiple specially crafted packets to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service."
|
||||
}
|
||||
]
|
||||
},
|
||||
|
@ -176,7 +176,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions), Soft Starter ES (All versions). Sending a specially crafted packet to the affected service could cause a\npartial remote Denial-of-Service, that would cause the service to restart\nitself.\n"
|
||||
"value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (All versions), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES (All versions), Soft Starter ES (All versions). Sending a specially crafted packet to the affected service could cause a partial remote Denial-of-Service, that would cause the service to restart itself."
|
||||
}
|
||||
]
|
||||
},
|
||||
|
Loading…
x
Reference in New Issue
Block a user