"-Synchronized-Data."

This commit is contained in:
CVE Team 2024-01-26 14:00:35 +00:00
parent 1a2898389f
commit c417e436c2
No known key found for this signature in database
GPG Key ID: E3252B3D49582C98
5 changed files with 309 additions and 12 deletions

View File

@ -1,17 +1,104 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2024-0921",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "cna@vuldb.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A vulnerability has been found in D-Link DIR-816 A2 1.10CNB04 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /goform/setDeviceSettings of the component Web Interface. The manipulation of the argument statuscheckpppoeuser leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252139."
},
{
"lang": "deu",
"value": "In D-Link DIR-816 A2 1.10CNB04 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Hierbei betrifft es unbekannten Programmcode der Datei /goform/setDeviceSettings der Komponente Web Interface. Durch Manipulieren des Arguments statuscheckpppoeuser mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-78 OS Command Injection",
"cweId": "CWE-78"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "D-Link",
"product": {
"product_data": [
{
"product_name": "DIR-816 A2",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "1.10CNB04"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://vuldb.com/?id.252139",
"refsource": "MISC",
"name": "https://vuldb.com/?id.252139"
},
{
"url": "https://vuldb.com/?ctiid.252139",
"refsource": "MISC",
"name": "https://vuldb.com/?ctiid.252139"
},
{
"url": "https://github.com/xiyuanhuaigu/cve/blob/main/rce.md",
"refsource": "MISC",
"name": "https://github.com/xiyuanhuaigu/cve/blob/main/rce.md"
}
]
},
"credits": [
{
"lang": "en",
"value": "xiyuanhuaigu (VulDB User)"
}
],
"impact": {
"cvss": [
{
"version": "3.1",
"baseScore": 4.7,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
"baseSeverity": "MEDIUM"
},
{
"version": "3.0",
"baseScore": 4.7,
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
"baseSeverity": "MEDIUM"
},
{
"version": "2.0",
"baseScore": 5.8,
"vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P"
}
]
}

View File

@ -1,17 +1,104 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2024-0922",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "cna@vuldb.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. Affected by this vulnerability is the function formQuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "deu",
"value": "In Tenda AC10U 15.03.06.49_multi_TDE01 wurde eine kritische Schwachstelle entdeckt. Betroffen ist die Funktion formQuickIndex. Durch das Manipulieren des Arguments PPPOEPassword mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121 Stack-based Buffer Overflow",
"cweId": "CWE-121"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Tenda",
"product": {
"product_data": [
{
"product_name": "AC10U",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "15.03.06.49_multi_TDE01"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://vuldb.com/?id.252127",
"refsource": "MISC",
"name": "https://vuldb.com/?id.252127"
},
{
"url": "https://vuldb.com/?ctiid.252127",
"refsource": "MISC",
"name": "https://vuldb.com/?ctiid.252127"
},
{
"url": "https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/formQuickIndex.md",
"refsource": "MISC",
"name": "https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/formQuickIndex.md"
}
]
},
"credits": [
{
"lang": "en",
"value": "chenjun ma (VulDB User)"
}
],
"impact": {
"cvss": [
{
"version": "3.1",
"baseScore": 4.7,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
"baseSeverity": "MEDIUM"
},
{
"version": "3.0",
"baseScore": 4.7,
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
"baseSeverity": "MEDIUM"
},
{
"version": "2.0",
"baseScore": 5.8,
"vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P"
}
]
}

View File

@ -1,17 +1,104 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2024-0923",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "cna@vuldb.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. Affected by this issue is the function formSetDeviceName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252128. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "deu",
"value": "Eine kritische Schwachstelle wurde in Tenda AC10U 15.03.06.49_multi_TDE01 entdeckt. Betroffen davon ist die Funktion formSetDeviceName. Durch Manipulieren des Arguments devName mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121 Stack-based Buffer Overflow",
"cweId": "CWE-121"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Tenda",
"product": {
"product_data": [
{
"product_name": "AC10U",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "15.03.06.49_multi_TDE01"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://vuldb.com/?id.252128",
"refsource": "MISC",
"name": "https://vuldb.com/?id.252128"
},
{
"url": "https://vuldb.com/?ctiid.252128",
"refsource": "MISC",
"name": "https://vuldb.com/?ctiid.252128"
},
{
"url": "https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/formSetDeviceName.md",
"refsource": "MISC",
"name": "https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/formSetDeviceName.md"
}
]
},
"credits": [
{
"lang": "en",
"value": "chenjun ma (VulDB User)"
}
],
"impact": {
"cvss": [
{
"version": "3.1",
"baseScore": 4.7,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
"baseSeverity": "MEDIUM"
},
{
"version": "3.0",
"baseScore": 4.7,
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
"baseSeverity": "MEDIUM"
},
{
"version": "2.0",
"baseScore": 5.8,
"vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P"
}
]
}

View File

@ -0,0 +1,18 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2024-0949",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
}
]
}
}

View File

@ -0,0 +1,18 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2024-0950",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
}
]
}
}