"-Synchronized-Data."

This commit is contained in:
CVE Team 2024-05-03 02:05:06 +00:00
parent 7dbf3233eb
commit d285343f67
No known key found for this signature in database
GPG Key ID: BC5FD8F2443B23B7
21 changed files with 1379 additions and 84 deletions

View File

@ -1,17 +1,77 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38081",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Kofax Power PDF JP2 File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kofax Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of JP2 files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-20487."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write",
"cweId": "CWE-787"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Kofax",
"product": {
"product_data": [
{
"product_name": "Power PDF",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.0.0.19"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-959/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-959/"
}
]
},
"source": {
"lang": "en",
"value": "Mat Powell of Trend Micro Zero Day Initiative"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,77 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38082",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Kofax Power PDF GIF File Parsing Memory Corruption Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kofax Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of GIF files. The issue results from the lack of proper validation of user-supplied data, which can result in a memory corruption condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-20488."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
"cweId": "CWE-119"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Kofax",
"product": {
"product_data": [
{
"product_name": "Power PDF",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.0.0.19"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-960/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-960/"
}
]
},
"source": {
"lang": "en",
"value": "Mat Powell of Trend Micro Zero Day Initiative"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,77 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38083",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Kofax Power PDF JP2 File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kofax Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of JP2 files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-20489."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write",
"cweId": "CWE-787"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Kofax",
"product": {
"product_data": [
{
"product_name": "Power PDF",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.0.0.19"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-961/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-961/"
}
]
},
"source": {
"lang": "en",
"value": "Mat Powell of Trend Micro Zero Day Initiative"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,77 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38084",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Kofax Power PDF PDF File Parsing Memory Corruption Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kofax Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of PDF files. The issue results from the lack of proper validation of user-supplied data, which can result in a memory corruption condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-20490."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
"cweId": "CWE-119"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Kofax",
"product": {
"product_data": [
{
"product_name": "Power PDF",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.0.0.19"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-923/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-923/"
}
]
},
"source": {
"lang": "en",
"value": "Mat Powell of Trend Micro Zero Day Initiative"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,77 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38085",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Kofax Power PDF JP2 File Parsing Out-Of-Bounds Read Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Kofax Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of JP2 files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-20491."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read",
"cweId": "CWE-125"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Kofax",
"product": {
"product_data": [
{
"product_name": "Power PDF",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.0.0.19"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-924/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-924/"
}
]
},
"source": {
"lang": "en",
"value": "Mat Powell of Trend Micro Zero Day Initiative"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"baseScore": 3.3,
"baseSeverity": "LOW"
}
]
}

View File

@ -1,17 +1,77 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38086",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Kofax Power PDF PDF File Parsing Out-Of-Bounds Read Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Kofax Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of PDF files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-20529."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read",
"cweId": "CWE-125"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Kofax",
"product": {
"product_data": [
{
"product_name": "Power PDF",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.0.0.19"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-922/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-922/"
}
]
},
"source": {
"lang": "en",
"value": "Mat Powell of Trend Micro Zero Day Initiative"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"baseScore": 3.3,
"baseSeverity": "LOW"
}
]
}

View File

@ -1,17 +1,77 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38087",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Kofax Power PDF clearTimeOut Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kofax Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the handling of app objects. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-20560."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write",
"cweId": "CWE-787"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Kofax",
"product": {
"product_data": [
{
"product_name": "Power PDF",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.0.0.19"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-963/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-963/"
}
]
},
"source": {
"lang": "en",
"value": "rgod"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,77 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38088",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Kofax Power PDF printf Uninitialized Variable Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kofax Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the handling of util objects. The issue results from the lack of proper initialization of memory prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-20566."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-457: Use of Uninitialized Variable",
"cweId": "CWE-457"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Kofax",
"product": {
"product_data": [
{
"product_name": "Power PDF",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.0.0.19"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-964/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-964/"
}
]
},
"source": {
"lang": "en",
"value": "rgod"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,77 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38089",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Kofax Power PDF clearInterval Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kofax Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the handling of app objects. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-20567."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write",
"cweId": "CWE-787"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Kofax",
"product": {
"product_data": [
{
"product_name": "Power PDF",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.0.0.19"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-962/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-962/"
}
]
},
"source": {
"lang": "en",
"value": "rgod"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,77 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38090",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Kofax Power PDF popUpMenu Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kofax Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the implementation of the app.popUpMenu method. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-20588."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow",
"cweId": "CWE-122"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Kofax",
"product": {
"product_data": [
{
"product_name": "Power PDF",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.0.0.19"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-965/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-965/"
}
]
},
"source": {
"lang": "en",
"value": "Mat Powell of Trend Micro Zero Day Initiative"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,77 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38091",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Kofax Power PDF response Type Confusion Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kofax Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the implementation of the app.response method. The issue results from the lack of proper validation of user-supplied data, which can result in a type confusion condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-20601."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-843: Access of Resource Using Incompatible Type ('Type Confusion')",
"cweId": "CWE-843"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Kofax",
"product": {
"product_data": [
{
"product_name": "Power PDF",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.0.0.19"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-969/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-969/"
}
]
},
"source": {
"lang": "en",
"value": "rgod"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,77 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38092",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Kofax Power PDF importDataObject Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kofax Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the implementation of the importDataObject method. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-20603."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121: Stack-based Buffer Overflow",
"cweId": "CWE-121"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Kofax",
"product": {
"product_data": [
{
"product_name": "Power PDF",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.0.0.19"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-966/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-966/"
}
]
},
"source": {
"lang": "en",
"value": "rgod"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,77 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38093",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Kofax Power PDF saveAs Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kofax Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the implementation of the saveAs method. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-20604."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121: Stack-based Buffer Overflow",
"cweId": "CWE-121"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Kofax",
"product": {
"product_data": [
{
"product_name": "Power PDF",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.0.0.19"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-967/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-967/"
}
]
},
"source": {
"lang": "en",
"value": "rgod"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,77 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38094",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "Kofax Power PDF replacePages Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kofax Power PDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the implementation of the replacePages method. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-20605."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121: Stack-based Buffer Overflow",
"cweId": "CWE-121"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Kofax",
"product": {
"product_data": [
{
"product_name": "Power PDF",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.0.0.19"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-968/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-968/"
}
]
},
"source": {
"lang": "en",
"value": "rgod"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38095",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "NETGEAR ProSAFE Network Management System MFileUploadController Unrestricted File Upload Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of NETGEAR ProSAFE Network Management System. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the MFileUploadController class. The issue results from the lack of proper validation of user-supplied data, which can allow the upload of arbitrary files. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-19717."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-434: Unrestricted Upload of File with Dangerous Type",
"cweId": "CWE-434"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "NETGEAR",
"product": {
"product_data": [
{
"product_name": "ProSAFE Network Management System",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "R.47.0.0 AutoCAD 2021 & R.47.0.0 AutoCAD LT 2021"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-921/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-921/"
},
{
"url": "https://kb.netgear.com/000065707/Security-Advisory-for-Multiple-Vulnerabilities-on-the-ProSAFE-Network-Management-System-PSV-2023-0024-PSV-2023-0025",
"refsource": "MISC",
"name": "https://kb.netgear.com/000065707/Security-Advisory-for-Multiple-Vulnerabilities-on-the-ProSAFE-Network-Management-System-PSV-2023-0024-PSV-2023-0025"
}
]
},
"source": {
"lang": "en",
"value": "Steven Seeley of Source Incite"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 8.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38096",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "NETGEAR ProSAFE Network Management System MyHandlerInterceptor Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of NETGEAR ProSAFE Network Management System. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the MyHandlerInterceptor class. The issue results from improper implementation of the authentication mechanism. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-19718."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287: Improper Authentication",
"cweId": "CWE-287"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "NETGEAR",
"product": {
"product_data": [
{
"product_name": "ProSAFE Network Management System",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "R.47.0.0 AutoCAD 2021 & R.47.0.0 AutoCAD LT 2021"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-920/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-920/"
},
{
"url": "https://kb.netgear.com/000065707/Security-Advisory-for-Multiple-Vulnerabilities-on-the-ProSAFE-Network-Management-System-PSV-2023-0024-PSV-2023-0025",
"refsource": "MISC",
"name": "https://kb.netgear.com/000065707/Security-Advisory-for-Multiple-Vulnerabilities-on-the-ProSAFE-Network-Management-System-PSV-2023-0024-PSV-2023-0025"
}
]
},
"source": {
"lang": "en",
"value": "Steven Seeley of Source Incite"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38097",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "NETGEAR ProSAFE Network Management System BkreProcessThread Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of NETGEAR ProSAFE Network Management System. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the BkreProcessThread class. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-19719."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-749: Exposed Dangerous Method or Function",
"cweId": "CWE-749"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "NETGEAR",
"product": {
"product_data": [
{
"product_name": "ProSAFE Network Management System",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "R.47.0.0 AutoCAD 2021 & R.47.0.0 AutoCAD LT 2021"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-919/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-919/"
},
{
"url": "https://kb.netgear.com/000065707/Security-Advisory-for-Multiple-Vulnerabilities-on-the-ProSAFE-Network-Management-System-PSV-2023-0024-PSV-2023-0025",
"refsource": "MISC",
"name": "https://kb.netgear.com/000065707/Security-Advisory-for-Multiple-Vulnerabilities-on-the-ProSAFE-Network-Management-System-PSV-2023-0024-PSV-2023-0025"
}
]
},
"source": {
"lang": "en",
"value": "Steven Seeley of Source Incite"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 7.2,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38098",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "NETGEAR ProSAFE Network Management System UpLoadServlet Unrestricted File Upload Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of NETGEAR ProSAFE Network Management System. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the UpLoadServlet class. The issue results from the lack of proper validation of user-supplied data, which can allow the upload of arbitrary files. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-19720."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-434: Unrestricted Upload of File with Dangerous Type",
"cweId": "CWE-434"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "NETGEAR",
"product": {
"product_data": [
{
"product_name": "ProSAFE Network Management System",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "R.47.0.0 AutoCAD 2021 & R.47.0.0 AutoCAD LT 2021"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-918/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-918/"
},
{
"url": "https://kb.netgear.com/000065707/Security-Advisory-for-Multiple-Vulnerabilities-on-the-ProSAFE-Network-Management-System-PSV-2023-0024-PSV-2023-0025",
"refsource": "MISC",
"name": "https://kb.netgear.com/000065707/Security-Advisory-for-Multiple-Vulnerabilities-on-the-ProSAFE-Network-Management-System-PSV-2023-0024-PSV-2023-0025"
}
]
},
"source": {
"lang": "en",
"value": "Steven Seeley of Source Incite"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 8.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38099",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "NETGEAR ProSAFE Network Management System getNodesByTopologyMapSearch SQL Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of NETGEAR ProSAFE Network Management System. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the getNodesByTopologyMapSearch function. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-19723."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')",
"cweId": "CWE-89"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "NETGEAR",
"product": {
"product_data": [
{
"product_name": "ProSAFE Network Management System",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "R.47.0.0 AutoCAD 2021 & R.47.0.0 AutoCAD LT 2021"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-917/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-917/"
},
{
"url": "https://kb.netgear.com/000065707/Security-Advisory-for-Multiple-Vulnerabilities-on-the-ProSAFE-Network-Management-System-PSV-2023-0024-PSV-2023-0025",
"refsource": "MISC",
"name": "https://kb.netgear.com/000065707/Security-Advisory-for-Multiple-Vulnerabilities-on-the-ProSAFE-Network-Management-System-PSV-2023-0024-PSV-2023-0025"
}
]
},
"source": {
"lang": "en",
"value": "Steven Seeley of Source Incite"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 8.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38100",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "NETGEAR ProSAFE Network Management System clearAlertByIds SQL Injection Privilege Escalation Vulnerability. This vulnerability allows remote attackers to escalate privileges on affected installations of NETGEAR ProSAFE Network Management System. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the clearAlertByIds function. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to escalate privileges to resources normally protected from the user. Was ZDI-CAN-19724."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')",
"cweId": "CWE-89"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "NETGEAR",
"product": {
"product_data": [
{
"product_name": "ProSAFE Network Management System",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "R.47.0.0 AutoCAD 2021 & R.47.0.0 AutoCAD LT 2021"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-916/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-916/"
},
{
"url": "https://kb.netgear.com/000065707/Security-Advisory-for-Multiple-Vulnerabilities-on-the-ProSAFE-Network-Management-System-PSV-2023-0024-PSV-2023-0025",
"refsource": "MISC",
"name": "https://kb.netgear.com/000065707/Security-Advisory-for-Multiple-Vulnerabilities-on-the-ProSAFE-Network-Management-System-PSV-2023-0024-PSV-2023-0025"
}
]
},
"source": {
"lang": "en",
"value": "Steven Seeley of Source Incite"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 8.8,
"baseSeverity": "HIGH"
}
]
}

View File

@ -1,17 +1,82 @@
{
"data_version": "4.0",
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ID": "CVE-2023-38101",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"STATE": "PUBLIC"
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "NETGEAR ProSAFE Network Management System SettingConfigController Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of NETGEAR ProSAFE Network Management System. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the SettingConfigController class. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-19725."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-749: Exposed Dangerous Method or Function",
"cweId": "CWE-749"
}
]
}
]
},
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "NETGEAR",
"product": {
"product_data": [
{
"product_name": "ProSAFE Network Management System",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "R.47.0.0 AutoCAD 2021 & R.47.0.0 AutoCAD LT 2021"
}
]
}
}
]
}
}
]
}
},
"references": {
"reference_data": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-915/",
"refsource": "MISC",
"name": "https://www.zerodayinitiative.com/advisories/ZDI-23-915/"
},
{
"url": "https://kb.netgear.com/000065707/Security-Advisory-for-Multiple-Vulnerabilities-on-the-ProSAFE-Network-Management-System-PSV-2023-0024-PSV-2023-0025",
"refsource": "MISC",
"name": "https://kb.netgear.com/000065707/Security-Advisory-for-Multiple-Vulnerabilities-on-the-ProSAFE-Network-Management-System-PSV-2023-0024-PSV-2023-0025"
}
]
},
"source": {
"lang": "en",
"value": "Steven Seeley of Source Incite"
},
"impact": {
"cvss": [
{
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 7.2,
"baseSeverity": "HIGH"
}
]
}