mirror of
https://github.com/CVEProject/cvelist.git
synced 2025-07-30 18:04:30 +00:00
"-Synchronized-Data."
This commit is contained in:
parent
22c8394e61
commit
d82415ffa7
@ -440,6 +440,11 @@
|
||||
"refsource": "MLIST",
|
||||
"name": "[samza-commits] 20210310 [GitHub] [samza] Telesia opened a new pull request #1471: SAMZA-2630: Upgrade dependencies for security fixes",
|
||||
"url": "https://lists.apache.org/thread.html/r352e40ca9874d1beb4ad95403792adca7eb295e6bc3bd7b65fabcc21@%3Ccommits.samza.apache.org%3E"
|
||||
},
|
||||
{
|
||||
"refsource": "MLIST",
|
||||
"name": "[beam-issues] 20210310 [jira] [Work logged] (BEAM-11227) Upgrade beam-vendor-grpc-1_26_0-0.3 to fix CVE-2020-27216",
|
||||
"url": "https://lists.apache.org/thread.html/r827d17bf6900eddc686f4b6ee16fc5e52ca0070f8df7612222c40ac5@%3Cissues.beam.apache.org%3E"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,61 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2020-35226",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ID": "CVE-2020-35226",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "n/a",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "NETGEAR JGS516PE/GS116Ev2 v2.6.0.43 devices allow unauthenticated users to modify the switch DHCP configuration by sending the corresponding write request command."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/",
|
||||
"refsource": "MISC",
|
||||
"name": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,61 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2020-35227",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ID": "CVE-2020-35227",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "n/a",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "A buffer overflow vulnerability in the access control section on NETGEAR JGS516PE/GS116Ev2 v2.6.0.43 devices (in the administration web panel) allows an attacker to inject IP addresses into the whitelist via the checkedList parameter to the delete command."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/",
|
||||
"refsource": "MISC",
|
||||
"name": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,61 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2020-35228",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ID": "CVE-2020-35228",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "n/a",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "A cross-site scripting (XSS) vulnerability in the administration web panel on NETGEAR JGS516PE/GS116Ev2 v2.6.0.43 devices allows remote attackers to inject arbitrary web script or HTML via the language parameter."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/",
|
||||
"refsource": "MISC",
|
||||
"name": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,61 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2020-35229",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ID": "CVE-2020-35229",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "n/a",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "The authentication token required to execute NSDP write requests on NETGEAR JGS516PE/GS116Ev2 v2.6.0.43 devices is not properly invalidated and can be reused until a new token is generated, which allows attackers (with access to network traffic) to effectively gain administrative privileges."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/",
|
||||
"refsource": "MISC",
|
||||
"name": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,61 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2020-35230",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ID": "CVE-2020-35230",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "n/a",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "Multiple integer overflow parameters were found in the web administration panel on NETGEAR JGS516PE/GS116Ev2 v2.6.0.43 devices. Most of the integer parameters sent through the web server can be abused to cause a denial of service attack."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/",
|
||||
"refsource": "MISC",
|
||||
"name": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,61 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2020-35231",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ID": "CVE-2020-35231",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "n/a",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "The NSDP protocol implementation on NETGEAR JGS516PE/GS116Ev2 v2.6.0.43 devices was affected by an authentication issue that allows an attacker to bypass access controls and obtain full control of the device."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/",
|
||||
"refsource": "MISC",
|
||||
"name": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,61 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2020-35232",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ID": "CVE-2020-35232",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "n/a",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "The TFTP firmware update mechanism on NETGEAR JGS516PE/GS116Ev2 v2.6.0.43 devices does not properly implement firmware validations, allowing remote attackers to write arbitrary data to internal memory."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/",
|
||||
"refsource": "MISC",
|
||||
"name": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -1,17 +1,61 @@
|
||||
{
|
||||
"data_type": "CVE",
|
||||
"data_format": "MITRE",
|
||||
"data_version": "4.0",
|
||||
"CVE_data_meta": {
|
||||
"ID": "CVE-2020-35233",
|
||||
"ASSIGNER": "cve@mitre.org",
|
||||
"STATE": "RESERVED"
|
||||
"ID": "CVE-2020-35233",
|
||||
"STATE": "PUBLIC"
|
||||
},
|
||||
"affects": {
|
||||
"vendor": {
|
||||
"vendor_data": [
|
||||
{
|
||||
"product": {
|
||||
"product_data": [
|
||||
{
|
||||
"product_name": "n/a",
|
||||
"version": {
|
||||
"version_data": [
|
||||
{
|
||||
"version_value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
]
|
||||
},
|
||||
"vendor_name": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
"data_format": "MITRE",
|
||||
"data_type": "CVE",
|
||||
"data_version": "4.0",
|
||||
"description": {
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
|
||||
"value": "The TFTP server fails to handle multiple connections on NETGEAR JGS516PE/GS116Ev2 v2.6.0.43 devices, and allows external attackers to force device reboots by sending concurrent connections, aka a denial of service attack."
|
||||
}
|
||||
]
|
||||
},
|
||||
"problemtype": {
|
||||
"problemtype_data": [
|
||||
{
|
||||
"description": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "n/a"
|
||||
}
|
||||
]
|
||||
}
|
||||
]
|
||||
},
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/",
|
||||
"refsource": "MISC",
|
||||
"name": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
@ -85,7 +85,7 @@
|
||||
"description_data": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "An information exposure through log file vulnerability exists in Cortex XSOAR software where the secrets configured for the SAML single sign-on (SSO) integration can be logged to the ‘/var/log/demisto/’ server logs when testing the integration during setup.\n\nThis logged information includes the private key and identity provider certificate used to configure the SAML SSO integration.\nThis issue impacts:\nCortex XSOAR 5.5.0 builds earlier than 98622;\nCortex XSOAR 6.0.1 builds earlier than 830029;\nCortex XSOAR 6.0.2 builds earlier than 98623;\nCortex XSOAR 6.1.0 builds earlier than 848144.\n"
|
||||
"value": "An information exposure through log file vulnerability exists in Cortex XSOAR software where the secrets configured for the SAML single sign-on (SSO) integration can be logged to the \u2018/var/log/demisto/\u2019 server logs when testing the integration during setup. This logged information includes the private key and identity provider certificate used to configure the SAML SSO integration. This issue impacts: Cortex XSOAR 5.5.0 builds earlier than 98622; Cortex XSOAR 6.0.1 builds earlier than 830029; Cortex XSOAR 6.0.2 builds earlier than 98623; Cortex XSOAR 6.1.0 builds earlier than 848144."
|
||||
}
|
||||
]
|
||||
},
|
||||
@ -129,8 +129,9 @@
|
||||
"references": {
|
||||
"reference_data": [
|
||||
{
|
||||
"refsource": "CONFIRM",
|
||||
"url": "https://security.paloaltonetworks.com/CVE-2021-3034"
|
||||
"refsource": "MISC",
|
||||
"url": "https://security.paloaltonetworks.com/CVE-2021-3034",
|
||||
"name": "https://security.paloaltonetworks.com/CVE-2021-3034"
|
||||
}
|
||||
]
|
||||
},
|
||||
@ -156,7 +157,7 @@
|
||||
"work_around": [
|
||||
{
|
||||
"lang": "eng",
|
||||
"value": "You must configure a new private key for SAML SSO integration and you should not use the 'Test' button at any time during setup until after you complete the Cortex XSOAR upgrade.\n\nYou must clear all server system log files located in the ‘/var/log/demisto/’ directory. There may be several files in this directory, including the server.log file and other archived server logs.\n\nYou can clear all server system logs by stopping the server and running the ‘rm /var/log/demisto/server*.log’ command from the console."
|
||||
"value": "You must configure a new private key for SAML SSO integration and you should not use the 'Test' button at any time during setup until after you complete the Cortex XSOAR upgrade.\n\nYou must clear all server system log files located in the \u2018/var/log/demisto/\u2019 directory. There may be several files in this directory, including the server.log file and other archived server logs.\n\nYou can clear all server system logs by stopping the server and running the \u2018rm /var/log/demisto/server*.log\u2019 command from the console."
|
||||
}
|
||||
],
|
||||
"x_affectedList": [
|
||||
|
Loading…
x
Reference in New Issue
Block a user